Increase of tibial slope reduces backside wear in medial mobile bearing unicompartmental knee arthroplasty

被引:31
作者
Weber, Patrick [1 ]
Schroeder, Christian [1 ]
Schmidutz, Florian [1 ]
Kraxenberger, Michael [1 ]
Utzschneider, Sandra [1 ]
Jansson, Volkmar [1 ]
Mueller, Peter E. [1 ]
机构
[1] Univ Munich, Univ Hosp, Dept Orthoped Surg, D-81377 Munich, Germany
关键词
Unicondylar knee arthroplasty; Wear; Knee simulator; Mobile bearing; Tibial slope; IN-VITRO; EARLY FAILURE; COMPONENT; SIMULATOR;
D O I
10.1016/j.clinbiomech.2013.08.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Unicondylar knee arthroplasty is a good alternative for patients in monocompartmental osteoarthritis. The revision rate in unicondylar knee arthroplasty is higher than in total knee arthroplasty. The influence of the tibial slope on wear in unicondylar knee arthroplasty has not been investigated so far. Methods: The influence of the tibial slope on wear was investigated in mobile bearing unicondylar knee prosthesis. This was positioned with four different tibial slopes (-4 degrees, 0 degrees, 4 degrees, 8 degrees) in a knee wear simulator simulating the human gait in a plane according to ISO 14243-2:2002(E). After this a kinematic analysis was performed and the inlays were observed under reflected-light-microscopy. Findings: Wear was significantly reduced with an increasing tibial slope (0 degrees: 3.46 mg/million cycles, SD: 0.59, 4 degrees slope: 152 mg/million cycles, SD: 0.06, 8 degrees slope group: 0.99 mg/million cycles, SD: 0.42). An anterior slope of -4 degrees also reduced wear (2.08 mg/million cycles, SD: 037). Kinematic analysis revealed a reduced translation between the inlay and the tibia with an increasing tibial slope. The backside of the inlays of the 4 and 8 slope group showed less wear pattern when observed under reflected-light microscopy. Interpretation: Increasing the tibial slope led to a reduced translation between the inlay and the prosthesis in the analysed mobile-bearing unicondylar knee arthroplasty and with this to a reduced backside wear. A tibial slope between 4 and 8 degrees can be recommended in mobile UKA to reduce wear, however, the influence on the ligaments has to be considered and needs to be investigated in further studies. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:904 / 909
页数:6
相关论文
共 26 条
[1]   Early failure of unicompartmental knee arthroplasty leading to revision [J].
Aleto, Thomas J. ;
Berend, Michael E. ;
Ritter, Merrill A. ;
Faris, Philip M. ;
Meneghini, R. Michael .
JOURNAL OF ARTHROPLASTY, 2008, 23 (02) :159-163
[2]  
[Anonymous], 2010, SWED KNEE ARTHR REG
[3]   The influence of tibial slope on maximal flexion after total knee arthroplasty [J].
Bellemans, J ;
Robijns, F ;
Duerinckx, J ;
Banks, S ;
Vandenneucker, H .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (03) :193-196
[4]   The wear of fixed and mobile bearing unicompartmental knee replacements [J].
Brockett, C. L. ;
Jennings, L. M. ;
Fisher, J. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H5) :511-519
[5]   Friction of total hip replacements with different bearings and loading conditions [J].
Brockett, Claire ;
Williams, Sophie ;
Jin, Zhongmin ;
Isaac, Graham ;
Fisher, John .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 81B (02) :508-515
[6]   In vitro study of inter-individual variation in posterior slope in the knee joint [J].
de Boer, Johannes J. ;
Blankevoort, Leendert ;
Kingma, Idsart ;
Vorster, Willie .
CLINICAL BIOMECHANICS, 2009, 24 (06) :488-492
[7]   Significant effect of the posterior tibial slope and medial/lateral ligament balance on knee flexion in total knee arthroplasty [J].
Fujimoto, Eisaku ;
Sasashige, Yoshiaki ;
Masuda, Yasuji ;
Hisatome, Takashi ;
Eguchi, Akio ;
Masuda, Tetsuo ;
Sawa, Mikiya ;
Nagata, Yoshinori .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (12) :2704-2712
[8]   Biotribology of alternative bearing materials for unicompartmental knee arthroplasty [J].
Grupp, Thomas M. ;
Utzschneider, Sandra ;
Schroeder, Christian ;
Schwiesau, Jens ;
Fritz, Bernhard ;
Maas, Allan ;
Bloemer, Wilhelm ;
Jansson, Volkmar .
ACTA BIOMATERIALIA, 2010, 6 (09) :3601-3610
[9]   Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty [J].
Hernigou, P ;
Deschamps, G .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (03) :506-511
[10]   Effect of tibial slope or posterior cruciate ligament release on knee kinematics [J].
Jojima, H ;
Whiteside, LA ;
Ogata, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :194-198