Simultaneous determination of 38 phosphodiestrase-5 inhibitors in illicit erectile dysfunction products by liquid chromatography-electrospray ionization-tandem mass spectrometry

被引:42
作者
Lee, Eung-Sun [1 ]
Lee, Ji Hyun [1 ]
Han, Kyoung Moon [1 ]
Kim, Ji Won [1 ]
Hwang, In Sun [1 ]
Cho, Sooyeul [1 ]
Han, Soon Young [1 ]
Kim, Jinho [1 ]
机构
[1] Korea Food & Drug Adm, Natl Inst Food & Drug Safety Evaluat, Toxicol Evaluat & Res Dept, Adv Anal Team, Cheongwon Gun 363700, Chungcheongbuk, South Korea
关键词
LC-MS/MS; PDE-5 inhibitors and their analogues; Illicit erectile dysfunction products; Validation; SYNTHETIC PHOSPHODIESTERASE-5 INHIBITORS; ION MOBILITY SPECTROMETRY; DIETARY-SUPPLEMENTS; COUNTERFEIT MEDICINES; SILDENAFIL; VARDENAFIL; ANALOGS; TADALAFIL; DRUGS; QUANTIFICATION;
D O I
10.1016/j.jpba.2013.05.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the development and validation of simultaneous analytical method for 38 compounds, sildenafil, tadalafil, vardenafil and their analogues in illicit erectile dysfunction (ED) products by the liquid chromatography-electrospray ionization-tandem mass method (LC-ESI-MS/MS). Chromatographic separation was performed on a C18 reversed-phase column using a gradient of solvent A: aqueous 2 mM ammonium formate solution and solvent B: acetonitrile (ACN). All components were monitored under time-scheduled multiple reaction monitoring (MRM) mode. The limits of detection (LOD) ranged from 0.004 ng/ml to 0.455 ng/ml and the limits of quantification (LOQ) ranged from 0.012 ng/ml to 1.5 ng/ml. Calibration curves were linear with correlation coefficients over 0.9991. Mean recoveries ranged from 73.6% to 111.3%, and relative standard deviation (RSD) was less than 10%. The intra- and inter-day precision ranged from 0.2% to 16.3% and from 0.2% to 17.0%, respectively. The proposed method was applied to investigate the 52 illicit ED products. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 25 条
[1]  
[Anonymous], 2009, Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens
[2]   2D and 3D DOSY 1H NMR, a useful tool for analysis of complex mixtures: Application to herbal drugs or dietary supplements for erectile dysfunction [J].
Balayssac, Stephane ;
Trefi, Saleh ;
Gilard, Veronique ;
Malet-Martino, Myriam ;
Martino, Robert ;
Delsuc, Marc-Andre .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (04) :602-612
[3]   Multianalyte determination of different classes of pesticides (acidic, triazines, phenyl ureas, anilines, organophosphates, molinate and propanil) by liquid chromatography-electrospray-tandem mass spectrometry [J].
da Cunha, ACB ;
de Alda, MJL ;
Barceló, D ;
Pizzolato, TM ;
dos Santos, JHZ .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (04) :940-954
[4]   A High-Performance Liquid Chromatography:Chemiluminescence Method for Potential Determination of Vardenafil in Dietary Supplement [J].
Di, Youjun ;
Zhao, Min ;
Nie, Yingchun ;
Wang, Fei ;
Lv, Jiagen .
JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY, 2011,
[5]   Accurate mass measurement using Fourier transform ion cyclotron resonance mass spectrometry for structure elucidation of designer drug analogs of tadalafil, vardenafil and sildenafil in herbal and pharmaceutical matrices [J].
Gratz, Samuel R. ;
Gamble, Bryan M. ;
Flurer, Rick A. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (15) :2317-2327
[6]   Analysis of undeclared synthetic phosphodiesterase-5 inhibitors in dietary supplements and herbal matrices by LC-ESI-MS and LC-UV [J].
Gratz, SR ;
Flurer, CL ;
Wolnik, KA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (03) :525-533
[7]   Detection of undeclared erectile dysfunction drugs and analogues in dietary supplements by ion mobility spectrometry [J].
Gryniewicz, Connie M. ;
Reepmeyer, John C. ;
Kauffman, John F. ;
Buhse, Lucinda F. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) :601-606
[8]  
KFDA (Korea Food and DrugAdministration), 2010, INSTR AN DAT ILL COM
[9]  
Kim SH, 2012, MASS SPECTROM LETT, V3, P50
[10]   Identification of a new tadalafil analogue found in a dietary supplement [J].
Lee, Eung-Sun ;
Kim, Ji Won ;
Lee, Ji Hyun ;
Han, Kyoung Moon ;
Cho, Sooyeul ;
Hwang, Insun ;
Han, Soon Young ;
Chae, Kabyong ;
Kim, Jinho .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (04) :621-626