Cetirizine dihydrochloride sensor based on nano composite chitosan, MWCNTs and ionic liquid

被引:19
作者
Gholivand, Mohammad Bagher [1 ]
Shamsipur, Mojtaba [1 ]
Ehzari, Hosna [1 ]
机构
[1] Razi Univ, Fac Sci, Dept Chem, Kermanshah, Iran
关键词
Cetirizine; Differential pulse adsorptive stripping voltammetry (DPAdSV); Nanocomposite; Chitosan; MWCNTs; Ionic liquid; CARBON; ELECTRODE; BIOSENSOR; NANOPARTICLES; ACID; ELECTROOXIDATION; CADMIUM;
D O I
10.1016/j.microc.2019.01.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a glassy carbon electrode was modified by nanocomposite of chitosan, MWCNTs and ionic liquid and used for electrooxidation study of cetirizine and it's sensing using differential pulse adsorptive stripping voltammetry (DPAdSV). Impedance spectroscopy, cyclic voltammetry (CV) and scanning electron microscopy (SEM) were used for electrode modification process. Correction of the electrode surface increased its response to target and improved the linear dynamic range (40 nM-480 mu M) and limit of detection 8 nM. The stability, reproducibility, and repeatability of the nanocomposite modified electrode were considered and it was used for the monitoring of cetirizine in serum and tablet as real samples.
引用
收藏
页码:692 / 700
页数:9
相关论文
共 50 条
  • [41] Preparation of the glucose sensor based on three-dimensional ordered macroporous gold film and room temperature ionic liquid
    Chen XiaoJun
    Xuan Jie
    Jiang LiPing
    Zhu JunJie
    SCIENCE IN CHINA SERIES B-CHEMISTRY, 2009, 52 (11): : 1999 - 2005
  • [42] A novel electrochemical quercetin sensor based on Pd/MoS2-ionic liquid functionalized ordered mesoporous carbon
    Xu, Bingjie
    Yang, Lite
    Zhao, Faqiong
    Zeng, Baizhao
    ELECTROCHIMICA ACTA, 2017, 247 : 657 - 665
  • [43] Amperometric glucose biosensor based on direct assembly of Prussian blue film with ionic liquid-chitosan matrix assisted enzyme immobilization
    Zhang, Yannan
    Liu, Yu
    Chu, Zhenyu
    Shi, Lei
    Jin, Wanqin
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 978 - 984
  • [44] Immunosensor for Myeloperoxidase Based on PoPD-MWCNTs-Ionic Liquid/Nanogold Modified Au Electrode
    Liu Bei
    Lu Lingsong
    Liu Chenggui
    Xie Guoming
    ACTA CHIMICA SINICA, 2011, 69 (04) : 438 - 444
  • [45] Voltammetric determination of cadmium (II) based on a composite film of a thiol-functionalized mesoporous molecular sieve and an ionic liquid
    Guo, Jing
    Luo, Yueping
    Ge, Fei
    Ding, Yonglan
    Fei, Junjie
    MICROCHIMICA ACTA, 2011, 172 (3-4) : 387 - 393
  • [46] Composite of ionic liquid decorated cyclodextrin nanosponge, graphene oxide and chitosan: A novel catalyst support
    Sadjadi, Samahe
    Heravi, Majid M.
    Raja, Maryam
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2019, 122 : 228 - 237
  • [47] Nonenzymatic nitrite sensor based on a titanium dioxide nanoparticles/ionic liquid composite electrode
    Li, Yonghong
    Wang, Haibo
    Liu, Xinsheng
    Guo, Le
    Ji, Xiaoling
    Wang, Ling
    Tian, Danian
    Yang, Xiaohui
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 719 : 35 - 40
  • [48] AMPEROMETRIC IMMUNOSENSOR FOR PROSTATE SPECIFIC ANTIGEN BASED ON GOLD NANOPARTICLES/IONIC LIQUID/CHITOSAN HYBRID FILM
    Lin, Jiehua
    He, Chunyan
    Pang, Xiujiang
    Hu, Kongcheng
    ANALYTICAL LETTERS, 2011, 44 (05) : 908 - 921
  • [49] Fabrication of modified carbon nano tubes based composite using ionic liquid for phenol removal
    Rajamohan, Natarajan
    Bosu, Subrajit
    Ngo, Gia Huy
    Al-Shibli, Noura
    MOLECULAR CATALYSIS, 2022, 533
  • [50] Electrochemistry of Hemoglobin in the Chitosan and TiO2 Nanoparticles Composite Film Modified Carbon Ionic Liquid Electrode and Its Electrocatalysis
    Sun, Wei
    Li, Xiaoqing
    Liu, Shufeng
    Jiao, Kui
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2009, 30 (03): : 582 - 588