Non-invasive cardiac allograft rejection surveillance: reliability and clinical value for prevention of heart failure

被引:8
|
作者
Dandel, Michael [1 ,2 ]
Hetzer, Roland [2 ]
机构
[1] German Ctr Heart & Circulatory Res DZHK, Partner Site Berlin, Berlin, Germany
[2] Cardio Ctr Berlin, D-10117 Berlin, Germany
关键词
Heart transplantation; Acute cellular rejection; Antibody-mediated rejection; Cardiac rejection surveillance; Echocardiography; Ventricular function; Cardiac imaging; Immune monitoring; Therapeutic decision-making; ANTIBODY-MEDIATED REJECTION; SPECKLE-TRACKING ECHOCARDIOGRAPHY; DONOR-SPECIFIC ANTIBODIES; ACUTE CELLULAR REJECTION; LONGITUDINAL MYOCARDIAL DEFORMATION; SIGNAL-AVERAGED ELECTROCARDIOGRAPHY; LEFT-VENTRICULAR DYSFUNCTION; TRANSPLANT REJECTION; STRAIN-RATE; ENDOMYOCARDIAL BIOPSY;
D O I
10.1007/s10741-020-10023-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Allograft rejection-related acute and chronic heart failure (HF) is a major cause of death in heart transplant recipients. Given the deleterious impact of late recognized acute rejection (AR) or non-recognized asymptomatic antibody-mediated rejection on short- and long-term allograft function improvement of AR surveillance and optimization of action strategies for confirmed AR can prevent AR-related allograft failure and delay the development of cardiac allograft vasculopathy, which is the major cause for HF after the first posttransplant year. Routine non-invasive monitoring of cardiac function can improve both detection and functional severity grading of AR. It can also be helpful in guiding the anti-AR therapy and timing of routine surveillance endomyocardial biopsies (EMBs). The combined use of EMBs with non-invasive technologies and methods, which allow detection of subclinical alterations in myocardial function (e.g., tissue Doppler imaging and speckle-tracking echocardiography), reveal alloimmune activation (e.g., screening of complement-activating donor-specific antibodies and circulating donor-derived cell-free DNA) and help in predicting the imminent risk of immune-mediated injury (e.g., gene expression profiling, screening of non-HLA antibodies, and circulating donor-derived cell-free DNA), can ensure the best possible surveillance and management of AR. This article gives an overview of the current knowledge about the reliability and clinical value of non-invasive cardiac allograft AR surveillance. Particular attention is focused on the potential usefulness of non-invasive tools and techniques for detection and functional grading of early and late ARs in asymptomatic patients. Overall, the review aimed to provide a theoretical and practical basis for those engaged in this particularly demanding up-to-date topic.
引用
收藏
页码:319 / 336
页数:18
相关论文
共 50 条
  • [41] Non-invasive imaging in acute decompensated heart failure with preserved ejection fraction
    Dhont, Sebastiaan
    Verbrugge, Frederik H.
    Verwerft, Jan
    Bertrand, Philippe B.
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2024, 13 (07) : 575 - 582
  • [42] Non-invasive Imaging in Women With Heart Failure — Diagnosis and Insights Into Disease Mechanisms
    Rebecca Kozor
    Aderonke Abiodun
    Katharine Kott
    Charlotte Manisty
    Current Heart Failure Reports, 2022, 19 : 114 - 125
  • [43] Non-Invasive Assessment of Congestion by Cardiovascular and Pulmonary Ultrasound and Biomarkers in Heart Failure
    Iliesiu, Adriana Mihaela
    Hodorogea, Andreea Simona
    Balahura, Ana-Maria
    Badila, Elisabeta
    DIAGNOSTICS, 2022, 12 (04)
  • [44] Non-invasive Imaging in Women With Heart Failure - Diagnosis and Insights Into Disease Mechanisms
    Kozor, Rebecca
    Abiodun, Aderonke
    Kott, Katharine
    Manisty, Charlotte
    CURRENT HEART FAILURE REPORTS, 2022, 19 (03) : 114 - 125
  • [45] Comprehensive non-invasive evaluation of the functional status of patients with chronic heart failure
    Koloskova, N. N.
    Eyyubova, A. Q.
    Shevchenko, A. O.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2024, 26 (01): : 88 - 96
  • [46] Eight-year experience of pediatric heart transplantation: Clinical outcome using non-invasive methods for the evaluation of acute rejection
    Azeka, E
    Marcial, MB
    Jatene, M
    Auler, JOC
    Ramires, JAF
    PEDIATRIC TRANSPLANTATION, 2002, 6 (03) : 208 - 213
  • [47] Should positron emission tomography be the standard of care for non-invasive surveillance following cardiac transplantation?
    Miller, Robert J. H.
    Kobashigawa, Jon A.
    Berman, Daniel S.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (02) : 655 - 659
  • [48] The value of routine non-invasive tests to predict clinical outcome in stable angina
    Daly, C
    Norrie, J
    Murdoch, DL
    Ford, I
    Dargie, HJ
    Fox, K
    EUROPEAN HEART JOURNAL, 2003, 24 (06) : 534 - 542
  • [49] Predictive value of left atrial volume measured by non-invasive cardiac imaging in the treatment of paroxysmal atrial fibrillation
    von Bary, Christian
    Dornia, Christian
    Eissnert, Christoph
    Nedios, Sotirios
    Roser, Mattias
    Hamer, Okka W.
    Gerds-Li, Jin-Hong
    Paetsch, Ingo
    Jahnke, Cosima
    Gebker, Rolf
    Weber, Stefan
    Fleck, Eckart
    Kriatselis, Charalampos
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (02) : 181 - 188
  • [50] Application value of myocardial work technology by non-invasive echocardiography in evaluating left ventricular function in patients with chronic heart failure
    Li, Yanan
    Zheng, Qiang
    Cui, Cunying
    Liu, Yuanyuan
    Hu, Yanbin
    Huang, Danqing
    Wang, Ying
    Liu, Jun
    Liu, Lin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 244 - 256