A configurable electrical capacitance tomography system using a combining electrode strategy

被引:30
|
作者
Yang, Yunjie [1 ]
Peng, Lihui [1 ]
机构
[1] Tsinghua Univ, Dept Automat, Tsinghua Natl Lab Informat Sci & Technol, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-phase flow; capacitance sensor; electrical capacitance tomography; image reconstruction; IMAGE-RECONSTRUCTION ALGORITHM; DESIGN; ECT; SIMULATIONS; SENSORS; LIQUID;
D O I
10.1088/0957-0233/24/7/074005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Systematic investigation of a combining electrode strategy for electrical capacitance tomography (ECT) is carried out. A configurable digital and analogue mixed ECT system using a combining electrode strategy is presented. Compared to the traditional ECT system, the presented system can be configured flexibly as the traditional ECT sensor mode and the combining electrode mode by connecting a number of electrodes as a combined electrode. In particular, the combining electrode mode is increasing the number of capacitance measurement data and the amelioration of sensitivity distribution. An image reconstruction framework is proposed by configuring the presented ECT system as the corresponding sensor mode adaptive to the permittivity distribution to be reconstructed, which includes the traditional ECT sensor mode, the symmetric combining electrode mode, the asymmetric combining electrode mode and the mixed combining electrode mode. Both simulation and experimental results show that image reconstructions with better quality and robustness to measurement noise can be obtained under the proposed adaptive image reconstruction framework by using the presented configurable ECT system.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Excitation Strategy for Three-dimensional Electrical Capacitance Tomography Sensor
    Mao, Mingxu
    Ye, Jiamin
    Wang, Haigang
    Zhang, Jiaolong
    Yang, Wuqiang
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST) PROCEEDINGS, 2015, : 49 - 54
  • [42] A fast parallel measurement and data acquisition strategy for Electrical capacitance tomography
    Lu, G
    Peng, LH
    Zhang, BF
    CHINESE JOURNAL OF ELECTRONICS, 2004, 13 (04): : 732 - 734
  • [43] Grain Moisture Sensing Using Electrical Capacitance Tomography
    Yu, Ling
    Zhang, Maomao
    Yang, Dong
    Loescher, Luke
    Soleimani, Manuchehr
    IEEE SENSORS JOURNAL, 2024, 24 (02) : 2038 - 2048
  • [44] Analysis of chaos in fluidization using electrical capacitance tomography
    Delft Univ of Technology, Delft, Netherlands
    Meas Sci Technol, 3 (361-368):
  • [45] Liquid material identification by using electrical capacitance tomography
    Li, N.
    Yang, X. D.
    Gong, Y.
    MATERIALS RESEARCH INNOVATIONS, 2015, 19 : S195 - S198
  • [46] Electrical Capacitance Tomography Using Incomplete Measurement Set
    Cui, Ziqiang
    Xia, Zihan
    Wang, Huaxiang
    IEEE ACCESS, 2019, 7 (79555-79564) : 79555 - 79564
  • [47] ENGINE FLAME IMAGING USING ELECTRICAL CAPACITANCE TOMOGRAPHY
    HE, R
    XIE, CG
    WATERFALL, RC
    BECK, MS
    BECK, CM
    ELECTRONICS LETTERS, 1994, 30 (07) : 559 - 560
  • [48] Electrical Capacitance Tomography Sensor Using Internal Electrodes
    Cui, Ziqiang
    Xia, Zihan
    Wang, Huaxiang
    IEEE SENSORS JOURNAL, 2020, 20 (06) : 3207 - 3216
  • [49] Imaging irregular structures using electrical capacitance tomography
    Chen, Zhao
    Chen, Meng
    Wang, Jiangjiang
    Liu, Rongzheng
    Shao, Youlin
    Liu, Bing
    Tang, Yaping
    Liu, Malin
    Yang, Wuqiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (07)
  • [50] Analysis of chaos in fluidization using electrical capacitance tomography
    Kuhn, FT
    Schouten, JC
    Mudde, RF
    vandenBleek, CM
    Scarlett, B
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (03) : 361 - 368