Detection of Mass Increase in a Fan Impeller With a Frequency Converter

被引:5
|
作者
Tamminen, Jussi [1 ]
Ahonen, Tero [1 ]
Ahola, Jero [1 ]
Niemela, Markku [1 ]
Tahvanainen, Arto [1 ]
Potinkara, Ari [1 ]
机构
[1] Lappeenranta Univ Technol, Inst Energy Technol, FI-53851 Lappeenranta, Finland
关键词
Diagnostics; fans; system identification; variable-speed drives (VSDs); ventilation; INDUCTION-MOTOR DRIVES; DIRECT TORQUE CONTROL; SENSORLESS CONTROL; SPEED; IDENTIFICATION; OBSERVERS; MACHINES; INPUT;
D O I
10.1109/TIE.2012.2207657
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Fan systems are often responsible for the ventilation of contaminated air, such as exhaust gases. Contaminants can build up on the fan impeller eventually causing a mechanical imbalance, which may lead to the fan breakdown and shutdown of production processes. Usually, the contamination buildup can be detected by visual inspection or from increased vibrations caused by the imbalance on the fan impeller. If the contamination buildup could be detected before the imbalance occurs, the unscheduled maintenance or even the failure of the fan system could be avoided. In this paper, a novelmethod is presented that can be used to detect the contamination buildup on the fan impeller. The method uses the capability of the frequency converter controlling the fan motor to estimate the rotational speed of the motor and the capability to control the motor torque. The presented method is validated by laboratory measurements.
引用
收藏
页码:3968 / 3975
页数:8
相关论文
共 50 条
  • [21] THEORETICAL BASIS OF EFFICIENT PARAMETERS OF THE IMPELLER OF A JET RADIAL FAN
    PARAKHONSKII, EV
    SOVIET MINING SCIENCE USSR, 1983, 19 (03): : 236 - 240
  • [22] Optimization for Impeller Parameters of Small Forward Curved Centrifugal Fan
    Chen J.
    Shi H.
    Zhao Y.
    Xi B.
    Geng D.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2022, 49 (12): : 75 - 82
  • [23] ARBITRARY SURFACE FLANK MILLING OF FAN, COMPRESSOR, AND IMPELLER BLADES
    WU, CY
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1995, 117 (03): : 534 - 539
  • [24] Stress analysis of centrifugal fan impeller by finite element method
    Bhat, M.G.
    Bhope, D.V.
    Journal of the Institution of Engineers (India), Part ME: Mechanical Engineering Division, 1990, 70 (pt 6):
  • [25] CHALLENGES IN THE DESIGN OF A NEW CENTRIFUGAL FAN WITH VARIABLE IMPELLER GEOMETRY
    Odyjas, Piotr
    Wieckowski, Jedrzej
    Pietrusiak, Damian
    Moczko, Przemyslaw
    ACTA MECHANICA ET AUTOMATICA, 2023, 17 (01) : 16 - 27
  • [26] OPTIMIZATION OF A CENTRIFUGAL FAN IMPELLER USING KRIGING SIMULATED ANNEALING
    Cadirci, Sertac
    Selenbas, Bugra
    Gunes, Hasan
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 6, PTS A AND B, 2012, : 991 - 997
  • [27] A study of impeller-diffuser-volute interaction in a centrifugal fan
    Meakhail, T
    Park, SO
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 84 - 90
  • [28] FLOW IN A CENTRIFUGAL FAN IMPELLER AT OFF-DESIGN CONDITIONS
    WRIGHT, T
    TZOU, KTS
    MADHAVAN, S
    MECHANICAL ENGINEERING, 1984, 106 (07) : 89 - 89
  • [29] FLOW IN A CENTRIFUGAL FAN IMPELLER AT OFF-DESIGN CONDITIONS
    WRIGHT, T
    TZOU, KTS
    MADHAVAN, S
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1984, 106 (04): : 913 - 919
  • [30] The influence of housing on the internal flow of a cross flow fan impeller
    Ciocanea, Adrian
    Marin, Alexandru
    Buretea, Dorin Laurentiu