Direct quantification of aromatic hydrocarbons in geochemical fluids with a mid-infrared attenuated total reflection sensor

被引:34
作者
Pejcic, Bobby [1 ]
Boyd, Leigh [2 ]
Myers, Matthew [1 ]
Ross, Andrew [1 ]
Raichlin, Yosef [3 ]
Katzir, Abraham [3 ]
Lu, Rui [4 ,5 ]
Mizaikoff, Boris [4 ]
机构
[1] CSIRO, Earth Sci & Resource Engn, Wealth Oceans Flagship, Kensington, WA 6151, Australia
[2] Natl Measurement Inst, Perth, WA 6151, Australia
[3] Tel Aviv Univ, Sch Phys & Astron, IL-69978 Tel Aviv, Israel
[4] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[5] Univ Sci & Technol China, Dept Chem, Hefei 230026, Peoples R China
关键词
CRYSTAL MICROBALANCE SENSOR; VOLATILE ORGANIC-COMPOUNDS; MARINE-ENVIRONMENT; INFRARED DETECTION; CHLORINATED HYDROCARBONS; AQUEOUS-SOLUTIONS; CHEMICAL SENSOR; WAVE-GUIDES; CRUDE OILS; WATER;
D O I
10.1016/j.orggeochem.2012.11.011
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
An improved analytical method for directly and rapidly quantifying various monocyclic and polycyclic aromatic molecules in oil-water mixtures has been developed. This study reports on the application of a sensor based on attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) for determining the concentration of a number of volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs) in water. The mid-infrared (MIR) sensor consists of a zinc selenide (ZnSe) waveguide with the surface modified by a thin poly(isobutylene) (PIB) coating. The sensitivity was investigated at different polymer film thicknesses and molecular weights. The analytical performance of the sensor was validated in the laboratory against a standard analytical technique for analyzing petroleum based samples. We have shown that the sensor may accurately quantify the benzene, toluene, ethylbenzene, xylenes and naphthalene (BTEXN) concentration in an oil-water mixture. The ATR-FTIR method overcomes the limitations associated with sampling/sample preparation and has the advantage that it may easily discriminate between meta-and para-xylene, which is difficult with conventional analytical techniques (i.e., GC). In addition, this technology may potentially be deployed in the field for geochemical mapping and to monitor in situ the concentration profile of a number of hydrocarbons in geological formations (e.g., petroleum systems). To demonstrate this, a miniaturized prototype of an ATR-IR sensor system taking advantage of planar-tapered silver halide fibers has been developed and tested. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 51 条
  • [41] Infrared detection of chlorinated hydrocarbons in water at ppb levels of concentrations
    Roy, G
    Mielczarski, JA
    [J]. WATER RESEARCH, 2002, 36 (07) : 1902 - 1908
  • [42] INFRARED OPTICAL-PROPERTIES OF POLYCRYSTALLINE SILVER-HALIDE FIBERS
    SAAR, A
    MOSER, F
    AKSELROD, S
    KATZIR, A
    [J]. APPLIED PHYSICS LETTERS, 1986, 49 (06) : 305 - 307
  • [43] Effect of plasticizers on a PVC sensing phase for evaluation of water contamination by aromatic hydrocarbons and fuels using infrared spectroscopy
    Santana Silva, Andrea Monteiro
    Pimentel, Maria Fernanda
    Raimundo, Ivo M., Jr.
    Almeida, Yeda M. B.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (01): : 222 - 230
  • [44] Alteration of crude oils from the Troll area by biodegradation: Analysis of oil and water samples
    Skaare, B. Barman
    Wilkes, H.
    Vieth, A.
    Rein, E.
    Barth, T.
    [J]. ORGANIC GEOCHEMISTRY, 2007, 38 (11) : 1865 - 1883
  • [45] Improved approaches to ecotoxicity testing of petroleum products
    Tsvetnenko, Y
    Evans, L
    [J]. MARINE POLLUTION BULLETIN, 2002, 45 (1-12) : 148 - 156
  • [46] Water monitoring system for oil contamination using polymer-coated quartz crystal microbalance chemical sensor
    Ueyama, S
    Hijikata, K
    Hirotsuji, J
    [J]. WATER SCIENCE AND TECHNOLOGY, 2002, 45 (4-5) : 175 - 180
  • [47] Ultra-sensitive mid-infrared evanescent field sensors combining thin-film strip waveguides with quantum cascade lasers
    Wang, Xiaofeng
    Kim, Seong-Soo
    Rossbach, Robert
    Jetter, Michael
    Michler, Peter
    Mizaikoff, Boris
    [J]. ANALYST, 2012, 137 (10) : 2322 - 2327
  • [48] Membrane-introduced infrared spectroscopic chemical sensing method for the detection of volatile organic compounds in aqueous solutions
    Yang, J
    Ramesh, A
    [J]. ANALYST, 2005, 130 (03) : 397 - 403
  • [49] Development of an SPME/ATR-IR chemical sensor for detection of phenol type compounds in aqueous solutions
    Yang, J
    Cheng, ML
    [J]. ANALYST, 2001, 126 (06) : 881 - 886
  • [50] External cavity widely tunable quantum cascade laser based hollow waveguide gas sensors for multianalyte detection
    Young, C.
    Kim, S. -S.
    Luzinova, Y.
    Weida, M.
    Arnone, D.
    Takeuchi, E.
    Day, T.
    Mizaikoff, B.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01): : 24 - 28