High heat flux Langmuir probe array for the DIII-D divertor plates

被引:60
作者
Watkins, J. G. [1 ]
Taussig, D. [2 ]
Boivin, R. L. [2 ]
Mahdavi, M. A. [2 ]
Nygren, R. E. [1 ]
机构
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
[2] Gen Atom Co, San Diego, CA 92186 USA
关键词
ceramics; cryopumping; divertors; graphite; heat conduction; Langmuir probes; plasma toroidal confinement; plasma transport processes; Tokamak devices;
D O I
10.1063/1.2982423
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two modular arrays of Langmuir probes designed to handle a heat flux of up to 25 MW/m(2) for 10 s exposures have been installed in the lower divertor target plates of the DIII-D tokamak. The 20 pyrolytic graphite probe tips have more than three times higher thermal conductivity and 16 times larger mass than the original DIII-D isotropic graphite probes. The probe tips have a fixed 12.5 degrees surface angle to distribute the heat flux more uniformly than the previous 6 mm diameter domed collectors and a symmetric "rooftop" design to allow operation with reversed toroidal magnetic field. A large spring-loaded contact area improves heat conduction from each probe tip through a ceramic insulator into a cooled graphite divertor floor tile. The probe tips, brazed to molybdenum foil to ensure good electrical contact, are mounted in a ceramic tray for electrical isolation and reliable cable connections. The new probes are located 1.5 cm radially apart in a staggered arrangement near the entrance to the lower divertor pumping baffle and are linearly spaced 3 cm apart on the shelf above the in-vessel cryopump. Typical target plate profiles of J(sat), T(e), and V(f) with 4 mm spatial resolution are shown.
引用
收藏
页数:4
相关论文
共 19 条
  • [11] MONK RJ, 1996, JETIR9602 EFDA
  • [12] Experimental divertor physics
    Pitcher, CS
    Stangeby, PC
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 1997, 39 (06) : 779 - 930
  • [13] LARGE PROBES IN TOKAMAK SCRAPE-OFF PLASMAS - THE COLLISIONLESS SCRAPE-OFF LAYER - OPERATION IN THE SHADOW OF LIMITERS OR DIVERTOR PLATES
    STANGEBY, PC
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1985, 18 (08) : 1547 - 1559
  • [14] ERRORS IN MEASURING ELECTRON TEMPERATURES USING A SINGLE LANGMUIR PROBE IN A MAGNETIC-FIELD
    TAGLE, JA
    STANGEBY, PC
    ERENTS, SK
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 1987, 29 (03) : 297 - 301
  • [15] TAUSSIG D, P 22 IEEE NPSS S FUS
  • [16] A general theory of the plasma of an arc
    Tonks, L
    Langmuir, I
    [J]. PHYSICAL REVIEW, 1929, 34 (06): : 0876 - 0922
  • [17] Fast reciprocating Langmuir probe for the DIII-D divertor
    Watkins, JG
    Hunter, J
    Tafoya, B
    Ulrickson, M
    Watson, RD
    Moyer, RA
    Cuthbertson, JW
    Gunner, G
    Lehmer, R
    Luong, P
    Hill, DN
    Mascaro, M
    Robinson, JI
    Snider, R
    Stambaugh, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01) : 373 - 376
  • [18] Reciprocating and fixed probe measurements of density and temperature in the DIII-D divertor
    Watkins, JG
    Moyer, RA
    Cuthbertson, JW
    Buchenauer, DA
    Carlstrom, TN
    Hill, DN
    Ulrickson, M
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1997, 241 : 645 - 649
  • [19] A FAST SCANNING PROBE FOR DIII-D
    WATKINS, JG
    SALMONSON, J
    MOYER, R
    DOERNER, R
    LEHMER, R
    SCHMITZ, L
    HILL, DN
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) : 4728 - 4730