Multiwavelength technique for open-path measurements of the concentrations of atmospheric constituents

被引:1
|
作者
Liudchik, A. M. [1 ]
机构
[1] Belarusian State Univ, Natl Sci Res Ctr Monitoring Ozonosphere, Minsk 220108, BELARUS
关键词
open-path measurement system; absolute measurement system; measurement errors;
D O I
10.1007/s10812-012-9626-y
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A multiwavelength technique for open-path spectrophotometric measurements of the concentrations of the principal constituents of the atmosphere is presented. It uses a standard least squares procedure to minimize deviations of the calculated optical thickness of the working path from the measured value. The novel feature of this technique is that the effects of various sources of error on the computational results are interpreted as the difference in spectra of the probe radiation propagating along the working path and a comparison path. This difference yields a systematic error that is independent of the actual concentrations. The advantage of the multiwavelength technique is that an increased number of measurement wavelengths significantly reduces the effect of the various sources of error on the results.
引用
收藏
页码:477 / 483
页数:7
相关论文
共 50 条
  • [41] Deviations in evapotranspiration measurements between enclosed- and open-path eddy covariance systems
    Kang, Minseok
    Cho, Sungsik
    Kim, Su-Jin
    Kim, Eunsook
    Kang, Mingu
    HYDROLOGICAL SCIENCES JOURNAL, 2025,
  • [42] Rapid, optical measurement of the atmospheric pressure on a fast research aircraft using open-path TDLAS
    Buchholz, B.
    Afchine, A.
    Ebert, V.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (11) : 3653 - 3666
  • [43] Application of the shifting method as a technique to correct for the background in quantitative analysis by open-path FTIR
    Giese-Bogdan, Stefanie
    Levine, Steven P.
    Molt, Karl
    Journal of the Air and Waste Management Association, 1999, 49 (02): : 114 - 124
  • [44] Open-Path High Sensitivity Atmospheric Ammonia Sensing with a 9 μm Quantum Cascade Laser
    Miller, David J.
    Zondlo, Mark A.
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [45] Compact and portable open-path sensor for simultaneous measurements of atmospheric N2O and CO using a quantum cascade laser
    Tao, Lei
    Sun, Kang
    Khan, M. Amir
    Miller, David J.
    Zondlo, Mark A.
    OPTICS EXPRESS, 2012, 20 (27): : 28106 - 28118
  • [46] Application of the shifting method as a technique to correct for the background in quantitative analysis by open-path FTIR
    Giese-Bogdan, S
    Levine, SP
    Molt, K
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (02): : 114 - 124
  • [47] Open-path eddy covariance measurements of ammonia fluxes from a beef cattle feedlot
    Sun, Kang
    Tao, Lei
    Miller, David J.
    Zondlo, Mark A.
    Shonkwiler, Kira B.
    Nash, Christina
    Ham, Jay M.
    AGRICULTURAL AND FOREST METEOROLOGY, 2015, 213 : 193 - 202
  • [48] Rejection criteria for open-path Fourier transform infrared spectrometry during continuous atmospheric monitoring
    Shao, Limin
    Pollard, Matthew J.
    Griffiths, Peter R.
    Westermann, Dale T.
    Bjorneberg, David L.
    VIBRATIONAL SPECTROSCOPY, 2007, 43 (01) : 78 - 85
  • [49] Measurements of Stable Isotopes in Atmospheric CO2 and H2O by Open-Path Fourier Transform Infrared Spectrometry
    Wang Wei
    Liu Wen-qing
    Zhang Tian-shu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (08) : 2017 - 2023
  • [50] Open-path Fourier transform infrared spectroscopy
    Tucker, MD
    Shaffer, RE
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 1999, 3 (02): : 67 - 68