The relationship between measurement method and corneal structure on apparent intraocular pressure in glaucoma and ocular hypertension

被引:9
作者
Nessim, Maged [1 ]
Mollan, Susan P. [2 ]
Wolffsohn, James S. [3 ]
Laiquzzaman, Mohammad [4 ]
Sivakumar, Subramaniam [4 ]
Hartley, Stephanie [1 ]
Shah, Sunil [1 ,3 ,4 ]
机构
[1] City Hosp, Birmingham & Midland Eye Ctr, Birmingham B18 7QH, W Midlands, England
[2] Univ Hosp Birmingham NHS Trust, Queen Elizabeth Hosp, Dept Ophthalmol, Birmingham B15 2WB, W Midlands, England
[3] Aston Univ, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, England
[4] Heart England NHS Fdn Trust, Solihull Hosp, Birmingham B91 2JL, W Midlands, England
关键词
Cornea; Intraocular pressure; Glaucoma; open angle; Ocular hypertension; Ocular tonometry; GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; OPEN-ANGLE GLAUCOMA; NORMAL-TENSION GLAUCOMA; RESPONSE ANALYZER; BIOMECHANICAL PROPERTIES; NONCONTACT TONOMETRY; THICKNESS; HYSTERESIS; REDUCTION;
D O I
10.1016/j.clae.2012.11.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyse the relationship between measured intraocular pressure (IOP) and central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF) in ocular hypertension (OHT), primary open-angle (POAG) and normal tension glaucoma (NTG) eyes using multiple tonometry devices. Methods: Right eyes of patients diagnosed with OHT (n=47), normal tension glaucoma (n=17) and POAG (n=50) were assessed, IOP was measured in random order with four devices: Goldmann applanation tonometry (GAT); Pascal(R) dynamic contour tonometer (DCT); Reichert(R) ocular response analyser (ORA); and Tono-Pen(R) XL. CCT was then measured using a hand-held ultrasonic pachymeter. CH and CRF were derived from the air pressure to corneal reflectance relationship of the ORA data. Results: Compared to the GAT, the Tonopen and ORA Goldmann equivalent (IOPg) and corneal compensated (IOPcc) measured higher IOP readings (F=19.351, p<0.001), particularly in NTG (F=12.604, p<0.001). DCT was closest to Goldmann IOP and had the lowest variance. CCT was significantly different (F=8.305, p<0.001) between the 3 conditions as was CH (F=6.854, p=0.002) and CRF (F=19.653, p<0.001). IOPcc measures were not affected by CCT. The DCT was generally not affected by corneal biomechanical factors. Conclusion: This study suggests that as the true pressure of the eye cannot be determined non-invasively, measurements from any tonometer should be interpreted with care, particularly when alterations in the corneal tissue are suspected. (C) 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 61
页数:5
相关论文
共 50 条
  • [41] Efficacy and safety of brimonidine and dorzolamide for intraocular pressure lowering in glaucoma and ocular hypertension
    Katz, L. Jay
    Simmons, Steven T.
    Craven, E. Randy
    CURRENT MEDICAL RESEARCH AND OPINION, 2007, 23 (12) : 2971 - 2983
  • [42] Acetylsalicylic acid does not reduce the intraocular pressure variation in ocular hypertension or glaucoma
    Lindén, C
    Alm, A
    EXPERIMENTAL EYE RESEARCH, 2000, 70 (03) : 281 - 283
  • [43] Comparison of Biomechanically Corrected Intraocular Pressure Obtained by Corvis ST and Goldmann Applanation Tonometry in Patients With Open-angle Glaucoma and Ocular Hypertension
    Ye, Yiming
    Yang, Yangfan
    Fan, Yanmei
    Lan, Min
    Yu, Keming
    Yu, Minbin
    JOURNAL OF GLAUCOMA, 2019, 28 (10) : 922 - 928
  • [44] Mean intraocular pressure and progression based on corneal thickness in patients with ocular hypertension
    A G P Konstas
    M T Irkec
    M A Teus
    B Cvenkel
    Y S Astakhov
    E D Sharpe
    G Hollo
    N Mylopoulos
    B Bozkurt
    C Pizzamiglio
    V V Potyomkin
    A M Alemu
    Q J Nasser
    J A Stewart
    W C Stewart
    Eye, 2009, 23 : 73 - 78
  • [45] Assessment of Corneal Biomechanical Properties in Normal Tension Glaucoma and Comparison With Open-angle Glaucoma, Ocular Hypertension, and Normal Eyes
    Grise-Dulac, Alice
    Saad, Alain
    Abitbol, Olivia
    Febbraro, Jean-Luc
    Azan, Elodie
    Moulin-Tyrode, Christine
    Gatinel, Damien
    JOURNAL OF GLAUCOMA, 2012, 21 (07) : 486 - 489
  • [46] A silent interplay between elevated intraocular pressure, glaucoma, and hypertension
    Sato, Tatsuya
    Umetsu, Araya
    Tanaka, Marenao
    Ohguro, Hiroshi
    Furuhashi, Masato
    HYPERTENSION RESEARCH, 2025, 48 (03) : 1208 - 1210
  • [47] Effect of diabetes mellitus on corneal biomechanics and measurement of intraocular pressure
    Scheler, Annabelle
    Spoerl, Eberhard
    Boehm, Andreas G.
    ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e447 - e451
  • [48] Corneal Biomechanical Properties of various types of glaucoma and their impact on measurement of intraocular pressure
    Zhang, Yang
    Bian, Ailing
    Hang, Qijun
    Li, Luee
    Zhang, Shunhua
    Cheng, Gangwei
    Zhou, Qi
    OPHTHALMIC RESEARCH, 2023, 66 (01) : 749 - 756
  • [49] Relationship between novel intraocular pressure measurement from Corvis ST and central corneal thickness and corneal hysteresis
    Matsuura, Masato
    Murata, Hiroshi
    Fujino, Yuri
    Yanagisawa, Mieko
    Nakao, Yoshitaka
    Tokumo, Kana
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (04) : 563 - 568
  • [50] Assessment of the Ocular Response Analyzer as a Tool for Intraocular Pressure Measurement
    Elsheikh, Ahmed
    Alhasso, Daad
    Kotecha, Aachal
    Garway-Heath, David
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (08):