The relationship between measurement method and corneal structure on apparent intraocular pressure in glaucoma and ocular hypertension

被引:9
|
作者
Nessim, Maged [1 ]
Mollan, Susan P. [2 ]
Wolffsohn, James S. [3 ]
Laiquzzaman, Mohammad [4 ]
Sivakumar, Subramaniam [4 ]
Hartley, Stephanie [1 ]
Shah, Sunil [1 ,3 ,4 ]
机构
[1] City Hosp, Birmingham & Midland Eye Ctr, Birmingham B18 7QH, W Midlands, England
[2] Univ Hosp Birmingham NHS Trust, Queen Elizabeth Hosp, Dept Ophthalmol, Birmingham B15 2WB, W Midlands, England
[3] Aston Univ, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, England
[4] Heart England NHS Fdn Trust, Solihull Hosp, Birmingham B91 2JL, W Midlands, England
关键词
Cornea; Intraocular pressure; Glaucoma; open angle; Ocular hypertension; Ocular tonometry; GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; OPEN-ANGLE GLAUCOMA; NORMAL-TENSION GLAUCOMA; RESPONSE ANALYZER; BIOMECHANICAL PROPERTIES; NONCONTACT TONOMETRY; THICKNESS; HYSTERESIS; REDUCTION;
D O I
10.1016/j.clae.2012.11.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyse the relationship between measured intraocular pressure (IOP) and central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF) in ocular hypertension (OHT), primary open-angle (POAG) and normal tension glaucoma (NTG) eyes using multiple tonometry devices. Methods: Right eyes of patients diagnosed with OHT (n=47), normal tension glaucoma (n=17) and POAG (n=50) were assessed, IOP was measured in random order with four devices: Goldmann applanation tonometry (GAT); Pascal(R) dynamic contour tonometer (DCT); Reichert(R) ocular response analyser (ORA); and Tono-Pen(R) XL. CCT was then measured using a hand-held ultrasonic pachymeter. CH and CRF were derived from the air pressure to corneal reflectance relationship of the ORA data. Results: Compared to the GAT, the Tonopen and ORA Goldmann equivalent (IOPg) and corneal compensated (IOPcc) measured higher IOP readings (F=19.351, p<0.001), particularly in NTG (F=12.604, p<0.001). DCT was closest to Goldmann IOP and had the lowest variance. CCT was significantly different (F=8.305, p<0.001) between the 3 conditions as was CH (F=6.854, p=0.002) and CRF (F=19.653, p<0.001). IOPcc measures were not affected by CCT. The DCT was generally not affected by corneal biomechanical factors. Conclusion: This study suggests that as the true pressure of the eye cannot be determined non-invasively, measurements from any tonometer should be interpreted with care, particularly when alterations in the corneal tissue are suspected. (C) 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 61
页数:5
相关论文
共 50 条
  • [1] ICare Pro: Age Dependent Effect of Central Corneal Thickness on Intraocular Pressure in Glaucoma and Ocular Hypertension Patients
    Hohberger, Bettina
    Sommerfeld, Carlos
    Lucio, Marianna
    Bergua, Antonio
    CURRENT EYE RESEARCH, 2020, 45 (06) : 668 - 674
  • [2] Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls
    Vinciguerra, Riccardo
    Rehman, Salwah
    Vallabh, Neeru A.
    Batterbury, Mark
    Czanner, Gabriela
    Choudhary, Anshoo
    Cheeseman, Robert
    Elsheikh, Ahmed
    Willoughby, Colin E.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (01) : 121 - 126
  • [3] Relationship between intraocular pressure and parameters of obesity in ocular hypertension
    Ahn, Min Won
    Lee, Ji Woong
    Shin, Jong Hoon
    Lee, Jong Soo
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (05) : 794 - 800
  • [4] Central corneal thickness and intraocular pressure in ocular hypertension
    Consuelo Gutierrez
    Jose R. V. Casaponsa
    Francisco Munoz
    Gema Rebolleda
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 463 - 463
  • [5] Corneal Biomechanics for Ocular Hypertension, Primary Open-Angle Glaucoma, and Amyloidotic Glaucoma: A Comparative Study by Corvis ST
    Silva, Nisa
    Ferreira, Andre
    Baptista, Pedro Manuel
    Figueiredo, Ana
    Reis, Rita
    Sampaio, Isabel
    Beirao, Joao
    Vinciguerra, Riccardo
    Meneres, Pedro
    Meneres, Maria Joao
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 71 - 83
  • [6] Relationship between intraocular pressure and parameters of obesity in ocular hypertension
    Min Won Ahn
    Ji Woong Lee
    Jong Hoon Shin
    Jong Soo Lee
    International Journal of Ophthalmology, 2020, (05) : 794 - 800
  • [7] Intraocular pressure measurement after corneal transplantation
    Bezerra, Bernardo de Padua Soares
    Chan, Elsie
    Chakrabarti, Rahul
    Vajpayee, Rasik B.
    SURVEY OF OPHTHALMOLOGY, 2019, 64 (05) : 639 - 646
  • [8] Corneal Hysteresis, Corneal Resistance Factor, and Intraocular Pressure Measurement in Patients with Scleroderma Using the Reichert Ocular Response Analyzer
    Emre, Sinan
    Kayikcioglu, Oezcan
    Ates, Halil
    Cinar, Esat
    Inceoglu, Nehir
    Yargucu, Figen
    Pirildar, Timur
    Oksel, Fahrettin
    CORNEA, 2010, 29 (06) : 628 - 631
  • [9] Assessment of the Ocular Response Analyzer as an Instrument for Measurement of Intraocular Pressure and Corneal Biomechanics
    Elsheikh, Ahmed
    Joda, Akram
    Abass, Ahmed
    Garway-Heath, David
    CURRENT EYE RESEARCH, 2015, 40 (11) : 1111 - 1119
  • [10] Investigational and experimental drugs for intraocular pressure reduction in ocular hypertension and glaucoma
    Lusthaus, Jed Asher
    Goldberg, Ivan
    EXPERT OPINION ON INVESTIGATIONAL DRUGS, 2016, 25 (10) : 1201 - 1208