Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode

被引:61
作者
Kumar, A. Anil [1 ]
Swamy, B. E. Kumara [2 ]
Rani, T. Shobha [1 ]
Ganesh, P. S. [2 ]
Raj, Y. Paul [1 ]
机构
[1] Dravidian Univ, Dept Chem, Kuppam 517425, Andhra Pradesh, India
[2] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shimoga 577451, Karnataka, India
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2019年 / 98卷
关键词
Catechol (CC); Hydroquinone (HQ); Glassy carbon electrode (GCE); Electropolymerization; Cyclic voltammetry (CV); SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; REDUCED GRAPHENE OXIDE; PASTE ELECTRODE; SIMULTANEOUS ELECTROANALYSIS; IONIC LIQUID; FILM; NANOTUBES; BEHAVIOR; SENSOR; POLYMERIZATION;
D O I
10.1016/j.msec.2018.12.055
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The electrochemical study of Catechol (CC) was studied in presence of Hydroquinone (HQ) using poly(murexide) modified glassy carbon electrode (MGCE) by cyclic voltammetric study. The modified electrode exhibited good affirmative response towards the electro chemical oxidation of CC in presence of HQ in 0.2 M phosphate buffer solution at the physiological of pH 7.4. The influence of scan rate, concentration and pH parameters were examined with the cyclic voltammetric method. The modified electrode showed good selectivity and sensitivity with an advantage of interference study and free determination of selected analytes in this experiment. Finally a simple, sensitive and selective method was developed for the determination of dihydroxybenzene isomeric compounds.
引用
收藏
页码:746 / 752
页数:7
相关论文
共 52 条
[1]   Honeycomb Carbon: A Review of Graphene [J].
Allen, Matthew J. ;
Tung, Vincent C. ;
Kaner, Richard B. .
CHEMICAL REVIEWS, 2010, 110 (01) :132-145
[2]   The Simultaneous Electrochemical Detection of Catechol and Hydroquinone with [Cu(Sal-β-Ala)(3,5-DMPz)2]/SWCNTs/GCE [J].
Alshahrani, Lina Abdullah ;
Li, Xi ;
Luo, Hui ;
Yang, Linlin ;
Wang, Mengmeng ;
Yan, Songling ;
Liu, Peng ;
Yang, Yuqin ;
Li, Quanhua .
SENSORS, 2014, 14 (12) :22274-22284
[3]   Carbon nanoparticle-chitosan composite electrode with anion, cation, and neutral binding sites: Dihydroxybenzene selectivity [J].
Amiri, Mandana ;
Ghaffari, Shahnaz ;
Bezaatpour, Abolfazl ;
Marken, Frank .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 162 (01) :194-200
[4]   Non-enzymatic voltammetric glucose sensor made of ternary NiO/Fe3O4-SH/para-amino hippuric acid nanocomposite [J].
Baghayeri, Mehdi ;
Amiri, Amirhassan ;
Alizadeh, Zahra ;
Veisi, Hojat ;
Hasheminejad, Ehteram .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 810 :69-77
[5]   Strongly fluorescent cysteamine-coated copper nanoclusters as a fluorescent probe for determination of picric acid [J].
Bao, Zhijun ;
Zhang, Kui ;
Jian, Jingyi ;
Hu, Ziwei ;
Yuan, Kaisong ;
Shao, Huikai ;
Peng, Kun ;
Jiang, Zhengjin ;
Zapien, Juan Antonio ;
Yan, Yehan ;
Zhang, Cheng ;
Zhou, Haibo .
MICROCHIMICA ACTA, 2018, 185 (11)
[6]  
Bard A., 2004, ELECTROCHEMICAL METH, Vvol. 677
[7]   Graphene-based materials in electrochemistry [J].
Chen, Da ;
Tang, Longhua ;
Li, Jinghong .
CHEMICAL SOCIETY REVIEWS, 2010, 39 (08) :3157-3180
[8]   On the electrochemistry of dopamine in aqueous solution. Part I: The role of [SDS] on the voltammetric behavior of dopamine on a carbon paste electrode [J].
Corona-Avendano, Silvia ;
Alarcon-Angeles, Georgina ;
Ramirez-Silva, Maria Teresa ;
Rosquete-Pina, Giselle ;
Romero-Romo, Mario ;
Palomar-Pardave, Manuel .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 609 (01) :17-26
[9]   Mesoporous cobalto-cobaltic oxide modified glassy carbon electrode for simultaneous detection of hydroquinone and catechol [J].
Cui, Shiqiang ;
Li, Li ;
Ding, Yaping ;
Zhang, Jiangjiang .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 782 :225-232
[10]   Simultaneous determination of phenol isomers in binary mixtures by differential pulse voltammetry using carbon fibre electrode and neural network with pruning as a multivariate calibration tool [J].
de Carvalho, RM ;
Mello, C ;
Kubota, LT .
ANALYTICA CHIMICA ACTA, 2000, 420 (01) :109-121