In Silico Investigation of SNR and Dermis Sensitivity for Optimum Dual-Channel Near-Infrared Glucose Sensor Designs for Different Skin Colors

被引:7
作者
Althobaiti, Murad [1 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Engn, Biomed Engn Dept, Dammam 31441, Saudi Arabia
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 10期
关键词
bioinstrumentation; dual-channel; glucose; near-infrared; NIR technology; sensors; SIMULATION;
D O I
10.3390/bios12100805
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diabetes is a serious health condition that requires patients to regularly monitor their blood glucose level, making the development of practical, compact, and non-invasive techniques essential. Optical glucose sensors-and, specifically, NIR sensors-have the advantages of being non-invasive, compact, inexpensive, and user-friendly devices. However, these sensors have low accuracy and are yet to be adopted by healthcare providers. In our previous work, we introduced a non-invasive dual-channel technique for NIR sensors, in which a long channel is utilized to measure the glucose level in the inner skin (dermis) layer, while a short channel is used to measure the noise signal of the superficial skin (epidermis) layer. In this work, we investigated the use of dual-NIR channels for patients with different skin colors (i.e., having different melanin concentrations). We also adopted a Monte Carlo simulation model that takes into consideration the differences between different skin layers, in terms of blood content, water content, melanin concentration in the epidermis layer, and skin optical proprieties. On the basis of the signal-to-noise ratio, as well as the sensitivities of both the epidermis and dermis layers, we suggest the selection of wavelengths and source-to-detector separation for optimal NIR channels under different skin melanin concentrations. This work facilitates the improved design of a compact and non-invasive NIR glucose sensor that can be utilized by patients with different skin colors.
引用
收藏
页数:10
相关论文
共 41 条
  • [1] Abd Salam N. A. B., 2016, J TELECOMMUNICATION, V8, P59
  • [2] Continuous Glucose Monitoring: A Brief Review for Primary Care Practitioners
    Ajjan, Ramzi
    Slattery, David
    Wright, Eugene
    [J]. ADVANCES IN THERAPY, 2019, 36 (03) : 579 - 596
  • [3] A Review of Non-Invasive Optical Systems for Continuous Blood Glucose Monitoring
    Alsunaidi, Bushra
    Althobaiti, Murad
    Tamal, Mahbubunnabi
    Albaker, Waleed
    Al-Naib, Ibraheem
    [J]. SENSORS, 2021, 21 (20)
  • [4] Optimization of Dual-Channel Near-Infrared Non-Invasive Glucose Level Measurement Sensors Based On Monte-Carlo Simulations
    Althobaiti, Murad
    Al-Naib, Ibraheem
    [J]. IEEE PHOTONICS JOURNAL, 2021, 13 (03):
  • [5] Recent Developments in Instrumentation of Functional Near-Infrared Spectroscopy Systems
    Althobaiti, Murad
    Al-Naib, Ibraheem
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (18):
  • [6] An Automated Preprocessing Method for Diffuse Optical Tomography to Improve Breast Cancer Diagnosis
    Althobaiti, Murad
    Vavadi, Hamed
    Zhu, Quing
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2018, 17 : 1 - 12
  • [7] How short is short? Optimum source-detector distance for short-separation channels in functional near-infrared spectroscopy
    Brigadoi, Sabrina
    Cooper, Robert J.
    [J]. NEUROPHOTONICS, 2015, 2 (02)
  • [8] In-silico investigation towards the non-invasive optical detection of blood lactate
    Chatterjee, Subhasri
    Budidha, Karthik
    Qassem, Meha
    Kyriacou, Panicos A.
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Investigating the origin of photoplethysmography using a multiwavelength Monte Carlo model
    Chatterjee, Subhasri
    Budidha, Karthik
    Kyriacou, Panayiotis A.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2020, 41 (08)
  • [10] Recent advances in electrochemical glucose biosensors: a review
    Chen, Chao
    Xie, Qingji
    Yang, Dawei
    Xiao, Hualing
    Fu, Yingchun
    Tan, Yueming
    Yao, Shouzhuo
    [J]. RSC ADVANCES, 2013, 3 (14): : 4473 - 4491