Effectiveness and safety of high-power and short-duration ablation for cavotricuspid isthmus ablation in atrial flutter

被引:8
|
作者
Kwon, Hee-Jin [1 ]
Lee, Seong Soo [1 ]
Park, Young Jun [2 ]
Park, Seung-Jung [1 ]
Park, Kyoung-Min [1 ]
Kim, June Soo [1 ]
On, Young Keun [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Heart Vasc & Stroke Inst, Dept Internal Med,Div Cardiol,Sch Med, 81 Irwon Ro, Seoul 06351, South Korea
[2] Yonsei Univ, Wonju Severance Christian Hosp, Dept Internal Med, Div Cardiol,Wonju Coll Med, Wonju, South Korea
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2020年 / 43卷 / 09期
关键词
cavotricuspid isthmus ablation; high-power short-duration; typical atrial flutter; RADIOFREQUENCY CATHETER ABLATION; PULMONARY VEIN ISOLATION; IRRIGATED-TIP; FIBRILLATION; ANATOMY;
D O I
10.1111/pace.14019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Despite many studies on new tools and strategies for cavotricuspid isthmus (CTI) ablation, there is an unmet need to improve the CTI ablation procedure. Recently, high-power short-duration (HPSD) ablation has been widely used for pulmonary vein (PV) isolation in atrial fibrillation. We evaluated the effectiveness and safety of HPSD for CTI ablation in atrial flutter (AFL). Methods Eighty-four patients who underwent CTI ablation with or without simultaneous PV isolation between January 2018 and February 2019 were enrolled in this prospective cohort study. We compared procedural characteristics, periprocedural complications, and recurrence of atrial tachyarrhythmia (ATa) between the HPSD group (50 W for 15 s) and conventional group (30 W for 60 s). Results A total of 84 patients were divided into the HPSD (n = 42) and conventional (n = 42) groups. Bidirectional CTI block was achieved in all patients and 95% achieved bidirectional block after the first-line ablation in both groups. Although there was no difference in the total number of ablation lines between the two groups (1.17 +/- 0.7 vs 1.38 +/- 0.8,P = .067), HPSD ablation significantly reduced total ablation time compared to the conventional group (236.0 +/- 85.6 vs 534.2 +/- 235.2 s,P .001). One pericardial tamponade was reported in the HPSD group. During the mean follow-up of 9.3 +/- 4.8 months, CTI-dependent AFL recurrence occurred in one patient in the HPSD group. Recurrence of ATa developed in 14 patients with no significant difference between the groups. Conclusion Our study demonstrates that HPSD CTI ablation is safe and can shorten procedure time.
引用
收藏
页码:941 / 946
页数:6
相关论文
共 50 条
  • [21] Selecting High-Power Short-Duration Radiofrequency Ablation How High Is High?
    Lee, Adam C.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (12) : 2584 - 2586
  • [22] Update on high-power short-duration ablation for pulmonary vein isolation
    Qiu, Jie
    Wang, Yan
    Wang, Dao W.
    Hu, Mei
    Chen, Guangzhi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (09) : 2499 - 2508
  • [23] High-power short-duration versus low-power long-duration ablation guided by the ablation index
    Sousa, Pedro A.
    Puga, Luis
    Barra, Sergio
    Adao, Luis
    Primo, Joao
    Khoueiry, Ziad
    Lebreiro, Ana
    Fonseca, Paulo
    Pereira, Mariana
    Lagrange, Philippe
    D'Avila, Andre
    Oliveiros, Barbara
    Elvas, Luis
    Goncalves, Lino
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 370 : 209 - 214
  • [24] Ablation index-guided high-power vs. moderate-power cavotricuspid isthmus ablation
    Chikata, Akio
    Kato, Takeshi
    Usuda, Kazuo
    Fujita, Shuhei
    Maruyama, Michiro
    Otowa, Kanichi
    Usuda, Keisuke
    Kusayama, Takashi
    Tsuda, Toyonobu
    Hayashi, Kenshi
    Takamura, Masayuki
    HEART AND VESSELS, 2023, 38 (01) : 90 - 95
  • [25] Safety and effectiveness of very-high-power, short-duration ablation in patients with atrial fibrillation: Preliminary results
    Mitrzak, Karolina
    Peller, Michal
    Krzowski, Bartosz
    Maciejewski, Cezary
    Balsam, Pawel
    Marchel, Michal
    Grabowski, Marcin
    Lodzinski, Piotr
    CARDIOLOGY JOURNAL, 2022,
  • [26] Safety and effectiveness of very-high-power, short-duration ablation in patients with atrial fibrillation: Preliminary results
    Mitrzak, Karolina
    Peller, Michal
    Krzowski, Bartosz
    Maciejewski, Cezary
    Balsam, Pawel
    Marchel, Michal
    Grabowski, Marcin
    Lodzinski, Piotr
    CARDIOLOGY JOURNAL, 2024, 31 (04) : 603 - 611
  • [27] Catheter selection for ablation of the cavotricuspid isthmus for treatment of typical atrial flutter
    Da Costa, Antoine
    Jamon, Yann
    Romeyer-Bouchard, Cecile
    Thevenin, Jerome
    Messier, Marc
    Isaaz, Karl
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 17 (02) : 93 - 101
  • [28] Catheter selection for ablation of the cavotricuspid isthmus for treatment of typical atrial flutter
    Antoine Da Costa
    Yann Jamon
    Cécile Romeyer-Bouchard
    Jérôme Thévenin
    Marc Messier
    Karl Isaaz
    Journal of Interventional Cardiac Electrophysiology, 2006, 17 : 93 - 101
  • [29] Identification of cavotricuspid isthmus voltage patterns in typical atrial flutter ablation
    Ribes, Francisco
    Ferrero-de-Loma-Osorio, Angel
    Sanchez-Gomez, Juan Miguel
    Bondanza, Lourdes
    Martinez-Brotons, Angel
    Ruiz-Granell, Ricardo
    JOURNAL OF ARRHYTHMIA, 2024, 40 (01) : 191 - 194
  • [30] The effect of first step right atrial mapping (FRAM) on ablation duration and fluoroscopy exposure during cavotricuspid isthmus ablation of atrial flutter
    Guan, Fu
    Saguner, Ardan M.
    Breitenstein, Alexander
    Wang, Mia
    Molitor, Nadine
    Brunckhorst, Corinna
    Wolber, Thomas
    Duru, Firat
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10