Effectiveness and safety of high-power and short-duration ablation for cavotricuspid isthmus ablation in atrial flutter

被引:8
|
作者
Kwon, Hee-Jin [1 ]
Lee, Seong Soo [1 ]
Park, Young Jun [2 ]
Park, Seung-Jung [1 ]
Park, Kyoung-Min [1 ]
Kim, June Soo [1 ]
On, Young Keun [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Heart Vasc & Stroke Inst, Dept Internal Med,Div Cardiol,Sch Med, 81 Irwon Ro, Seoul 06351, South Korea
[2] Yonsei Univ, Wonju Severance Christian Hosp, Dept Internal Med, Div Cardiol,Wonju Coll Med, Wonju, South Korea
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2020年 / 43卷 / 09期
关键词
cavotricuspid isthmus ablation; high-power short-duration; typical atrial flutter; RADIOFREQUENCY CATHETER ABLATION; PULMONARY VEIN ISOLATION; IRRIGATED-TIP; FIBRILLATION; ANATOMY;
D O I
10.1111/pace.14019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Despite many studies on new tools and strategies for cavotricuspid isthmus (CTI) ablation, there is an unmet need to improve the CTI ablation procedure. Recently, high-power short-duration (HPSD) ablation has been widely used for pulmonary vein (PV) isolation in atrial fibrillation. We evaluated the effectiveness and safety of HPSD for CTI ablation in atrial flutter (AFL). Methods Eighty-four patients who underwent CTI ablation with or without simultaneous PV isolation between January 2018 and February 2019 were enrolled in this prospective cohort study. We compared procedural characteristics, periprocedural complications, and recurrence of atrial tachyarrhythmia (ATa) between the HPSD group (50 W for 15 s) and conventional group (30 W for 60 s). Results A total of 84 patients were divided into the HPSD (n = 42) and conventional (n = 42) groups. Bidirectional CTI block was achieved in all patients and 95% achieved bidirectional block after the first-line ablation in both groups. Although there was no difference in the total number of ablation lines between the two groups (1.17 +/- 0.7 vs 1.38 +/- 0.8,P = .067), HPSD ablation significantly reduced total ablation time compared to the conventional group (236.0 +/- 85.6 vs 534.2 +/- 235.2 s,P .001). One pericardial tamponade was reported in the HPSD group. During the mean follow-up of 9.3 +/- 4.8 months, CTI-dependent AFL recurrence occurred in one patient in the HPSD group. Recurrence of ATa developed in 14 patients with no significant difference between the groups. Conclusion Our study demonstrates that HPSD CTI ablation is safe and can shorten procedure time.
引用
收藏
页码:941 / 946
页数:6
相关论文
共 50 条
  • [1] High-Power Short-Duration Ablation of Paroxysmal and Persistent Atrial Fibrillation
    Hoyos, Carolina
    Matos, Carlos D.
    Miranda-Arboleda, Andres F.
    Patino, Carlos
    Hincapie, Daniela
    Osorio, Jose
    Zei, Paul C.
    Romero, Jorge E.
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (12)
  • [2] High-power, short-duration ablation for atrial fibrillation: Pros and cons
    Knotts, Robert J.
    Barbhaiya, Chirag R.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2021, 66 : 86 - 91
  • [3] High-power short-duration ablation of atrial fibrillation: A contemporary review
    Naniwadekar, Aditi
    Dukkipati, Srinivas R.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (03): : 528 - 540
  • [4] Cavotricuspid isthmus ablation by means of very high power, short-duration, temperature-controlled lesions
    Schillaci, Vincenzo
    Strisciuglio, Teresa
    Stabile, Giuseppe
    Salito, Armando
    Arestia, Alberto
    Agresta, Alessia
    Shopova, Gergana
    De Simone, Antonio
    Solimene, Francesco
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (01) : 97 - 102
  • [5] Efficacy and Safety of High-Power Short-Duration Radiofrequency Catheter Ablation of Atrial Fibrillation
    Park, Je-Wook
    Yang, Song-Yi
    Kim, Min
    Yu, Hee Tae
    Kim, Tae-Hoon
    Uhm, Jae-Sun
    Joung, Boyoung
    Lee, Moon-Hyoung
    Pak, Hui-Nam
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [6] The evolution of high-power short-duration atrial fibrillation ablation: "The long slog"
    Winkle, Roger A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (02) : 342 - 344
  • [7] Comparison of traditional radiofrequency ablation and high-power short-duration ablation in the treatment of atrial tachyarrhythmias
    Yakushev, A., V
    Paratsii, O. Z.
    ZAPOROZHYE MEDICAL JOURNAL, 2022, 24 (04) : 385 - 389
  • [8] HPSD ablation for AF high-power short-duration RF ablation for atrial fibrillation: A review
    Winkle, Roger A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (10) : 2813 - 2823
  • [9] With Great Power Comes Great Responsibility: Defining the Safety of High-Power Short-Duration Atrial Ablation
    Sauer, William H.
    Tzou, Wendy S.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (06)
  • [10] Comparison of Effectiveness and Safety between High-Power Short-Duration Ablation and Conventional Ablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis
    Jin, Shuyu
    Fu, Lu
    Jiang, Junrong
    Ye, Xingdong
    Liu, Huiyi
    Chen, Yanlin
    Pu, Sijia
    Wu, Shulin
    Xue, Yumei
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2022, 2022