Auto-masked 2D/3D image registration and its validation with clinical cone-beam computed tomography

被引:15
作者
Steininger, P. [1 ]
Neuner, M. [1 ]
Weichenberger, H. [1 ,2 ]
Sharp, G. C. [3 ]
Winey, B. [3 ]
Kametriser, G. [2 ]
Sedlmayer, F. [1 ,2 ]
Deutschmann, H. [1 ,2 ]
机构
[1] Paracelsus Med Univ, Inst Res & Dev Adv Radiat Technol radART, A-5020 Salzburg, Austria
[2] Paracelsus Med Univ, Univ Clin Radiotherapy & Radiooncol, A-5020 Salzburg, Austria
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
GUIDED RADIATION-THERAPY; 2D-3D REGISTRATION; DIGITAL TOMOSYNTHESIS; CT; RADIOTHERAPY; RECONSTRUCTION; IMPLEMENTATION; GUIDANCE; SYSTEMS;
D O I
10.1088/0031-9155/57/13/4277
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Image-guided alignment procedures in radiotherapy aim at minimizing discrepancies between the planned and the real patient setup. For that purpose, we developed a 2D/3D approach which rigidly registers a computed tomography (CT) with two x-rays by maximizing the agreement in pixel intensity between the x-rays and the corresponding reconstructed radiographs from the CT. Moreover, the algorithm selects regions of interest (masks) in the x-rays based on 3D segmentations from the pre-planning stage. For validation, orthogonal x-ray pairs from different viewing directions of 80 pelvic cone-beam CT (CBCT) raw data sets were used. The 2D/3D results were compared to corresponding standard 3D/3D CBCT-to-CT alignments. Outcome over 8400 2D/3D experiments showed that parametric errors in root mean square were <0.18 degrees (rotations) and <0.73 mm (translations), respectively, using rank correlation as intensity metric. This corresponds to a mean target registration error, related to the voxels of the lesser pelvis, of <2mm in 94.1% of the cases. From the results we conclude that 2D/3D registration based on sequentially acquired orthogonal x-rays of the pelvis is a viable alternative to CBCT-based approaches if rigid alignment on bony anatomy is sufficient, no volumetric intra-interventional data set is required and the expected error range fits the individual treatment prescription.
引用
收藏
页码:4277 / 4292
页数:16
相关论文
共 50 条
[31]   3D cone beam computed tomography reconstruction images in diagnosis of ameloblastomas of lower jaw: A case report and mini review [J].
Li, Dize ;
Yang, Zhiqiang ;
Chen, Tao ;
Guan, Chao ;
Wang, Feilong ;
Matz, Ethan L. ;
Zhang, Yuanyuan ;
Ji, Ping .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (01) :133-140
[32]   Dynamic 2D Ultrasound and 3D CT Image Registration of the Beating Heart [J].
Huang, Xishi ;
Moore, John ;
Guiraudon, Gerard ;
Jones, Douglas L. ;
Bainbridge, Daniel ;
Ren, Jing ;
Peters, Terry M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (08) :1179-1189
[33]   Fast and Robust 3D to 2D Image Registration by Backprojection of Gradient Covariances [J].
Spiclin, Ziga ;
Likar, Bostjan ;
Pernus, Franjo .
BIOMEDICAL IMAGE REGISTRATION (WBIR 2014), 2014, 8545 :124-133
[34]   A modified McKinnon-Bates (MKB) algorithm for improved 4D cone-beam computed tomography (CBCT) of the lung [J].
Star-Lack, Josh ;
Sun, Mingshan ;
Oelhafen, Markus ;
Berkus, Timo ;
Pavkovich, John ;
Brehm, Marcus ;
Arheit, Marcel ;
Paysan, Pascal ;
Wang, Adam ;
Munro, Peter ;
Seghers, Dieter ;
Carvalho, Luis Melo ;
Verbakel, W. F. A. R. .
MEDICAL PHYSICS, 2018, 45 (08) :3783-3799
[35]   Stochastic rank correlation: A robust merit function for 2D/3D registration of image data obtained at different energies [J].
Birkfellner, Wolfgang ;
Stock, Markus ;
Figl, Michael ;
Gendrin, Christelle ;
Hummel, Johann ;
Dong, Shuo ;
Kettenbach, Joachim ;
Georg, Dietmar ;
Bergmann, Helmar .
MEDICAL PHYSICS, 2009, 36 (08) :3420-3428
[36]   Respiratory triggered 4D cone-beam computed tomography: A novel method to reduce imaging dose [J].
Cooper, Benjamin J. ;
O'Brien, Ricky T. ;
Balik, Salim ;
Hugo, Geoffrey D. ;
Keall, Paul J. .
MEDICAL PHYSICS, 2013, 40 (04)
[37]   SNAFusion: Distilling 2D Axial Plane Diffusion Priors for Sparse-View 3D Cone-Beam CT Imaging [J].
Li, Xiaoyue ;
Cai, Tielong ;
Shang, Kai ;
Butala, Mark D. ;
Wang, Gaoang .
DEEP GENERATIVE MODELS, DGM4MICCAI 2024, 2025, 15224 :64-74
[38]   Validation for 2D/3D registration I: A new gold standard data set [J].
Pawiro, S. A. ;
Markelj, P. ;
Pernus, F. ;
Gendrin, C. ;
Figl, M. ;
Weber, C. ;
Kainberger, F. ;
Noebauer-Huhmann, I. ;
Bergmeister, H. ;
Stock, M. ;
Georg, D. ;
Bergmann, H. ;
Birkfellner, W. .
MEDICAL PHYSICS, 2011, 38 (03) :1481-1490
[39]   3D morphometric analysis of the human incudomallear complex using clinical cone-beam CT [J].
Soons, Joris A. M. ;
Danckaers, Femke ;
Keustermans, William ;
Huysmans, Toon ;
Sijbers, Jan ;
Casselman, Jan W. ;
Dirckx, Joris J. J. .
HEARING RESEARCH, 2016, 340 :79-88
[40]   A new gold-standard dataset for 2D/3D image registration evaluation [J].
Pawiro, Supriyanto ;
Markelj, Primoz ;
Gendrin, Christelle ;
Figl, Michael ;
Stock, Markus ;
Bloch, Christoph ;
Weber, Christoph ;
Unger, Ewald ;
Noebauer, Iris ;
Kainberger, Franz ;
Bergmeister, Helga ;
Georg, Dietmar ;
Bergmann, Helmar ;
Birkfellner, Wolfgang .
MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625