Auto-masked 2D/3D image registration and its validation with clinical cone-beam computed tomography

被引:15
作者
Steininger, P. [1 ]
Neuner, M. [1 ]
Weichenberger, H. [1 ,2 ]
Sharp, G. C. [3 ]
Winey, B. [3 ]
Kametriser, G. [2 ]
Sedlmayer, F. [1 ,2 ]
Deutschmann, H. [1 ,2 ]
机构
[1] Paracelsus Med Univ, Inst Res & Dev Adv Radiat Technol radART, A-5020 Salzburg, Austria
[2] Paracelsus Med Univ, Univ Clin Radiotherapy & Radiooncol, A-5020 Salzburg, Austria
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
GUIDED RADIATION-THERAPY; 2D-3D REGISTRATION; DIGITAL TOMOSYNTHESIS; CT; RADIOTHERAPY; RECONSTRUCTION; IMPLEMENTATION; GUIDANCE; SYSTEMS;
D O I
10.1088/0031-9155/57/13/4277
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Image-guided alignment procedures in radiotherapy aim at minimizing discrepancies between the planned and the real patient setup. For that purpose, we developed a 2D/3D approach which rigidly registers a computed tomography (CT) with two x-rays by maximizing the agreement in pixel intensity between the x-rays and the corresponding reconstructed radiographs from the CT. Moreover, the algorithm selects regions of interest (masks) in the x-rays based on 3D segmentations from the pre-planning stage. For validation, orthogonal x-ray pairs from different viewing directions of 80 pelvic cone-beam CT (CBCT) raw data sets were used. The 2D/3D results were compared to corresponding standard 3D/3D CBCT-to-CT alignments. Outcome over 8400 2D/3D experiments showed that parametric errors in root mean square were <0.18 degrees (rotations) and <0.73 mm (translations), respectively, using rank correlation as intensity metric. This corresponds to a mean target registration error, related to the voxels of the lesser pelvis, of <2mm in 94.1% of the cases. From the results we conclude that 2D/3D registration based on sequentially acquired orthogonal x-rays of the pelvis is a viable alternative to CBCT-based approaches if rigid alignment on bony anatomy is sufficient, no volumetric intra-interventional data set is required and the expected error range fits the individual treatment prescription.
引用
收藏
页码:4277 / 4292
页数:16
相关论文
共 50 条
  • [21] An Innovative Approach to Reduce Streaking Artifacts in FDK Based 3D Cone-beam Tomography
    Bhowmik, Ujjal Kumar
    Sudeepth, Araveti Venkata
    Adhami, Reza R.
    [J]. IEEE SOUTHEASTCON 2011: BUILDING GLOBAL ENGINEERS, 2011, : 359 - 364
  • [22] Evaluation of similarity measures for 3D/2D image registration
    Skerl, Darko
    Likar, Bostjan
    Pernus, Franjo
    [J]. MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [23] 2D radiographs, cone-beam computed tomography and 3D CBCT-based planning software in access cavity preparation: A single blinded randomised controlled in vitro study
    Christofzik, David W.
    Glandorf, Patrick
    Conrad, Jonas
    El-Sayed, Karim M. Fawzy
    Groessner-Schreiber, Birte
    Doerfer, Christof E.
    [J]. AUSTRALIAN ENDODONTIC JOURNAL, 2022, 48 (02) : 283 - 296
  • [24] A novel evaluation model of image registration for cone-beam computed tomography guided lung cancer radiotherapy
    Liu, Yimei
    Chen, Meining
    Fang, Jianlan
    Xiao, Liangjie
    Liu, Songran
    Li, Qiwen
    Qiu, Bo
    Huang, Runda
    Zhang, Jun
    Peng, Yinglin
    [J]. THORACIC CANCER, 2024, 15 (17) : 1333 - 1342
  • [25] Twin robotic x-ray system for 2D radiographic and 3D cone-beam CT imaging
    Fieselmann, Andreas
    Steinbrener, Jan
    Jerebko, Anna K.
    Voigt, Johannes M.
    Scholz, Rosemarie
    Ritschl, Ludwig
    Mertelmeier, Thomas
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [26] Evaluation of Computed Tomography to Ultrasound 2D Image Registration for Atrial Fibrillation Treatment
    Sandoval, Zulma L.
    Dillenseger, Jean-Louis
    [J]. 2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 245 - 248
  • [27] 5D respiratory motion model based image reconstruction algorithm for 4D cone-beam computed tomography
    Liu, Jiulong
    Zhang, Xue
    Zhang, Xiaoqun
    Zhao, Hongkai
    Gao, Yu
    Thomas, David
    Low, Daniel A.
    Gao, Hao
    [J]. INVERSE PROBLEMS, 2015, 31 (11)
  • [28] Motion-aware temporal regularization for improved 4D cone-beam computed tomography
    Mory, Cyril
    Janssens, Guillaume
    Rit, Simon
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (18) : 6856 - 6877
  • [29] Influence of imaging source and panel position uncertainties on the accuracy of 2D/3D image registration of cranial images
    Warmerdam, Guy
    Steininger, Philipp
    Neuner, Markus
    Sharp, Gregory
    Winey, Brian
    [J]. MEDICAL PHYSICS, 2012, 39 (09) : 5547 - 5556
  • [30] Intraoperative 3D imaging with cone-beam computed tomography leads to revision of pedicle screws in dorsal instrumentation: a retrospective analysis
    Zimmermann, Felix
    Kohl, Katharina
    Privalov, Maxim
    Franke, Jochen
    Vetter, Sven Y.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)