Auto-masked 2D/3D image registration and its validation with clinical cone-beam computed tomography

被引:15
作者
Steininger, P. [1 ]
Neuner, M. [1 ]
Weichenberger, H. [1 ,2 ]
Sharp, G. C. [3 ]
Winey, B. [3 ]
Kametriser, G. [2 ]
Sedlmayer, F. [1 ,2 ]
Deutschmann, H. [1 ,2 ]
机构
[1] Paracelsus Med Univ, Inst Res & Dev Adv Radiat Technol radART, A-5020 Salzburg, Austria
[2] Paracelsus Med Univ, Univ Clin Radiotherapy & Radiooncol, A-5020 Salzburg, Austria
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
GUIDED RADIATION-THERAPY; 2D-3D REGISTRATION; DIGITAL TOMOSYNTHESIS; CT; RADIOTHERAPY; RECONSTRUCTION; IMPLEMENTATION; GUIDANCE; SYSTEMS;
D O I
10.1088/0031-9155/57/13/4277
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Image-guided alignment procedures in radiotherapy aim at minimizing discrepancies between the planned and the real patient setup. For that purpose, we developed a 2D/3D approach which rigidly registers a computed tomography (CT) with two x-rays by maximizing the agreement in pixel intensity between the x-rays and the corresponding reconstructed radiographs from the CT. Moreover, the algorithm selects regions of interest (masks) in the x-rays based on 3D segmentations from the pre-planning stage. For validation, orthogonal x-ray pairs from different viewing directions of 80 pelvic cone-beam CT (CBCT) raw data sets were used. The 2D/3D results were compared to corresponding standard 3D/3D CBCT-to-CT alignments. Outcome over 8400 2D/3D experiments showed that parametric errors in root mean square were <0.18 degrees (rotations) and <0.73 mm (translations), respectively, using rank correlation as intensity metric. This corresponds to a mean target registration error, related to the voxels of the lesser pelvis, of <2mm in 94.1% of the cases. From the results we conclude that 2D/3D registration based on sequentially acquired orthogonal x-rays of the pelvis is a viable alternative to CBCT-based approaches if rigid alignment on bony anatomy is sufficient, no volumetric intra-interventional data set is required and the expected error range fits the individual treatment prescription.
引用
收藏
页码:4277 / 4292
页数:16
相关论文
共 50 条
  • [11] Artifact Reduction in 3D and 4D Cone-Beam Computed Tomography Images With Deep Learning: A Review
    Amirian, Mohammadreza
    Barco, Daniel
    Herzig, Ivo
    Schilling, Frank-Peter
    IEEE ACCESS, 2024, 12 : 10281 - 10295
  • [12] Quantifying the accuracy of deformable image registration for cone-beam computed tomography with a physical phantom
    Wu, Richard Y.
    Liu, Amy Y.
    Williamson, Tyler D.
    Yang, Jinzhong
    Wisdom, Paul G.
    Zhu, Xiaorong R.
    Frank, Steven J.
    Fuller, Clifton D.
    Gunn, Gary B.
    Gao, Song
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 92 - 100
  • [13] 3D exemplar-based random walks for tooth segmentation from cone-beam computed tomography images
    Pei, Yuru
    Ai, Xingsheng
    Zha, Hongbin
    Xu, Tianmin
    Ma, Gengyu
    MEDICAL PHYSICS, 2016, 43 (09) : 5040 - 5050
  • [14] Estimation of Rectal Dose Using Daily Megavoltage Cone-Beam Computed Tomography and Deformable Image Registration
    Akino, Yuichi
    Yoshioka, Yasuo
    Fukuda, Shoichi
    Maruoka, Shintaroh
    Takahashi, Yutaka
    Yagi, Masashi
    Mizuno, Hirokazu
    Isohashi, Fumiaki
    Ogawa, Kazuhiko
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (03): : 602 - 608
  • [15] Self-calibration of cone-beam CT geometry using 3D-2D image registration
    Ouadah, S.
    Stayman, J. W.
    Gang, G. J.
    Ehtiati, T.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07) : 2613 - 2632
  • [16] Accuracy of 3D Reconstructions Based on Cone Beam Computed Tomography
    Maret, D.
    Molinier, F.
    Braga, J.
    Peters, O. A.
    Telmon, N.
    Treil, J.
    Inglese, J. M.
    Cossie, A.
    Kahn, J. L.
    Sixou, M.
    JOURNAL OF DENTAL RESEARCH, 2010, 89 (12) : 1465 - 1469
  • [17] An unsupervised 2D-3D deformable registration network (2D3D-RegNet) for cone-beam CT estimation
    Zhang, You
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07)
  • [18] 3D cone-beam tomosynthesis provides axial imaging of the spine with lower radiation compared to computed tomography
    Upasani, Vidyadhar V.
    Bandaralage, Harsha
    Farnsworth, Christine L.
    SPINE DEFORMITY, 2021, 9 (01) : 41 - 49
  • [19] Cone-beam computed tomography evaluation of the pterygomaxillary fissure and pterygopalatine fossa using 3D rendering programs
    Icen, Murat
    Orhan, Kaan
    SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (05) : 513 - 522
  • [20] Going from 3D/3D to 2D/3D registration for noncoplanar setup verification in intracranial single-isocenter multiple-target hypofractionated stereotactic radiotherapy: comparison between kilo-voltage/mega-voltage image pairs and noncoplanar cone-beam computed tomography
    Lai, Jialu
    Liu, Shoupeng
    Liu, Jia
    Fu, Maoyue
    Jiang, Maoqiong
    Li, An
    Li, Bin
    Li, Xinke
    Cheng, Xiaqin
    Zhou, Lin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (12) : 8094 - +