Simple near-infrared time-correlated single photon counting instrument with a pulsed diode laser and avalanche photodiode for time-resolved measurements in scanning applications

被引:16
作者
Zhang, YL
Soper, SA [1 ]
Middendorf, LR
Wurm, JA
Erdmann, R
Wahl, M
机构
[1] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
[2] LI COR Inc, Lincoln, NE 68504 USA
[3] PicoQuant GmbH, D-12484 Berlin, Germany
关键词
near-IR; TCSPC; diode laser; avalanche photodiode; fluorescence lifetime; scanning lifetime instrument;
D O I
10.1366/0003702991947018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A simple apparatus for time-correlated single photon counting (TCSPC) measurements in the near-infrared (near-IR) region for scanning-type applications has been constructed and examined. The apparatus consisted of five major components including a pulsed diode laser source (lasing wavelength = 780 nm; repetition rate = 80 MHz; power = 5 mW; pulse width = 150 ps), an integrated microscope, a large-photoactive-area avalanche photodiode (APD), a TCSPC PC-board including the electronics, and a Windows-based software package for accumulating the fluorescence decay profiles. The instrument response function (IRF) of this assembly was found to be 460 ps, which is adequate for measuring lifetimes with tau(f) greater than or equal to 500 ps, Due to the small size of the device, it also allowed implementation into scanning experiments where lifetimes were measured. To demonstrate this capability, we scanned a three-well microscope slide containing a near-IR dye. The decay profile of the near-IR dye, aluminum 2,3-naphthalocyanine, was collected and analyzed to obtain its lifetime, which was found to be 2.73 ns, in close agreement with the literature value for this particular dye. In addition, a three-dimensional plot showing the decay profiles (time vs. photocounts) and scan position of aluminum 2,3-naphthalocyanine fluorescence was acquired by scanning the microscope head over this three-well glass slide. In the scanning mode, the IRFs as well as the decays of the dyes were found to be very stable. The device demonstrated a concentration detection sensitivity of 0.44 nM; however, the dynamic range was limited due to the slow time constant (passive quenching) associated with the APD.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 34 条
[1]  
[Anonymous], 1983, EXCITED STATE LIFETI
[3]   Near-infrared tetra-substituted aluminum 2,3-naphthalocyanine dyes for optical fiber applications [J].
Casay, GA ;
Narayanan, N ;
Evans, L ;
Czuppon, T ;
Patonay, G .
TALANTA, 1996, 43 (11) :1997-2005
[4]   ONLINE FLUORESCENCE LIFETIME DETECTION FOR CHROMATOGRAPHIC PEAK RESOLUTION [J].
COBB, WT ;
MCGOWN, LB .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :186-189
[5]   ACTIVE-QUENCHING AND GATING CIRCUITS FOR SINGLE-PHOTON AVALANCHE-DIODES (SPADS) [J].
COVA, S ;
LONGONI, A ;
RIPAMONTI, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) :599-601
[6]  
COVA S, 1995, P SPIE INT SOC OPT E, V2388
[7]   MEASUREMENT OF FLUORESCENCE LIFETIMES DURING LIQUID-CHROMATOGRAPHY [J].
DESILETS, DJ ;
KISSINGER, PT ;
LYTLE, FE .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1830-1834
[8]  
ERDMANN R, 1995, P SOC PHOTO-OPT INS, V2388, P330, DOI 10.1117/12.208493
[9]  
ERDMANN R, 1996, P SPIE A, V2680, P17
[10]   BINARY SOLVENT EFFECTS IN CAPILLARY ZONE ELECTROPHORESIS WITH ULTRASENSITIVE NEAR-IR FLUORESCENCE DETECTION OF RELATED TRICARBOCYANINE DYES AND DYE-LABELED AMINO-ACIDS [J].
FLANAGAN, JH ;
LEGENDRE, BL ;
HAMMER, RP ;
SOPER, SA .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :341-347