PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011)
|
2011年
关键词:
Cooling;
Active thermal control;
Reliability;
Power cycling;
Regulation;
D O I:
暂无
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
This work proposes a cooling strategy which responds to changes both in the power dissipation and in the base-plate or heat-sink temperature of power devices and modifies the system thermal impedance accordingly. That allows to reduce both the amplitude of power cycles (i.e., active cycles, due to self-heating effects) and of thermal cycles (i.e., passive cycles, due to changes in ambient temperature), yielding lesser thermo-mechanical stresses and improved system performance and reliability. This paper considers the particular case of forced-convection air-cooling and provides proof-of-concept experimental demonstration of the approach. Though not yet optimised, the potentiality of the proposed cooling strategy is well demonstrated.