Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading: A Three-Dimensional Finite Element Analysis

被引:28
作者
Oliveira, Helder [1 ]
Velasco, Aritza Brizuela [2 ]
Rios-Santos, Jose-Vicente [3 ]
Lasheras, Fernando Sanchez [4 ]
Lemos, Bernardo Ferreira [1 ]
Gil, Francisco Javier [5 ]
Carvalho, Alexandrine [1 ]
Herrero-Climent, Mariano [6 ]
机构
[1] Univ Fernando Pessoa, Fac Hlth Sci, P-4200150 Porto, Portugal
[2] Univ Oviedo, Dept Surg & Med Surg Specialties, Oviedo 33006, Spain
[3] Univ Seville, Sch Dent, Dept Periodontol, Seville 41009, Spain
[4] Univ Oviedo, Fac Sci, Math Dept, Oviedo 33007, Spain
[5] Univ Int Catalunya, Bioengn Inst Technol, Barcelona 08017, Spain
[6] Porto Dent Inst, P-4150518 Oporto, Portugal
关键词
dental implants; design; finite element analysis; strain distribution; stress distribution; bone quality; CONTROLLED CLINICAL-TRIAL; DENTAL IMPLANTS; OSSEOINTEGRATED IMPLANTS; EDENTULOUS PATIENTS; PRIMARY STABILITY; BONE-RESORPTION; EXTRACTION; IMMEDIATE; MICROMOTION; INTERFACE;
D O I
10.3390/ijerph17134738
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same length and diameter were used. The three-dimensional geometry of the bone was simulated with a cortical bone of three different thicknesses and two medullar bone densities: low density (150 Hounsfield units) and high density (850 Hounsfield units). A 30 degrees oblique load of 150 N was applied to the implant restoration. Displacement and stress (von Mises) results were obtained for bone and dental implants. The strain and stress distributions to the bone were higher for the tissue-level implant for all types of bone. The maximum principal strain and stress decreased with an increase in cortical bone thickness for both cancellous bone densities. The distribution of the load was concentrated at the coronal portion of the bone and implants. All implants showed a good distribution of forces for non-axial loads, with higher forces concentrated at the crestal region of the bone-implant interface. Decrease in medullar bone density negatively affects the strain and stress produced by the implants.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 48 条
  • [1] Effects of different implant surfaces and designs on marginal bone-level alterations: a review
    Abrahamsson, Ingemar
    Berglundh, Tord
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 : 207 - 215
  • [2] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [3] Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials
    Araki, Haruka
    Nakano, Tamaki
    Ono, Shinji
    Yatani, Hirofumi
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [4] Effect of platform switching on peri-implant bone: A 3D finite element analysis
    Aslam, Ayesha
    Hassan, Syed Hammad
    Aslam, Hammad Mudasser
    Khan, Danish Azeem
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (06) : 935 - 940
  • [5] Platform Switching for Marginal Bone Preservation Around Dental implants: A Systematic Review and Meta-Analysis
    Atieh, Momen A.
    Ibrahim, Hadeel M.
    Atieh, Ahmad H.
    [J]. JOURNAL OF PERIODONTOLOGY, 2010, 81 (10) : 1350 - 1366
  • [6] THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS
    Baggi, Luigi
    Cappelloni, Ilaria
    Di Girolamo, Michele
    Maceri, Franco
    Vairo, Giuseppe
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06) : 422 - 431
  • [7] Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog
    Barbier, L
    Vander Sloten, J
    Krzesinski, G
    Schepers, E
    Van Der Perre, G
    [J]. JOURNAL OF ORAL REHABILITATION, 1998, 25 (11) : 847 - 858
  • [8] Long-Term Outcome of One-Piece Implants. Part I: Implant Characteristics and Loading Protocols. A Systematic Literature Review with Meta-Analysis
    Barrachina-Diez, Jose M.
    Tashkandi, Esam
    Stampf, Susanne
    Att, Wael
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 503 - +
  • [9] Implant stability measurements for implants placed at the time of extraction: A cohort, prospective clinical trial
    Becker, W
    Sennerby, L
    Bedrossian, E
    Becker, BE
    Lucchini, JP
    [J]. JOURNAL OF PERIODONTOLOGY, 2005, 76 (03) : 391 - 397
  • [10] Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1