A Flexible Ultrasound Scanning System for Minimally Invasive Spinal Surgery Navigation

被引:12
作者
Zhang, Jingyu [1 ]
Wang, Yunjiang [1 ]
Liu, Tianjian [2 ]
Yang, Keji [3 ]
Jin, Haoran [4 ]
机构
[1] Zhejiang Univ, Dept Mech Engn, Hangzhou 310012, Peoples R China
[2] Zhejiang Univ, Affiliated Hosp 2, Dept Neurosurg, Sch Med, Hangzhou 310009, Peoples R China
[3] Zhejiang Univ, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310012, Peoples R China
[4] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore, Singapore
来源
IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS | 2021年 / 3卷 / 02期
基金
中国国家自然科学基金;
关键词
Decoupled control strategy; flexible fixture; force controller; trajectory planning; phantom experiment; PREVALENCE; RADIATION; FORCE; ROBOT;
D O I
10.1109/TMRB.2021.3075750
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Minimally invasive surgery has become the primary treatment of spine disease. It depends on high-precision medical image as guidance. Ultrasound imaging is expected to replace X-ray fluoroscopy as a golden standard scheme of minimally invasive spinal surgeries. Researchers make effort to develop ultrasound imaging for the process of navigation, taking its distinctive advantages of user-friendly and radiation-free. However, it is greatly affected by the contact force and incident angle of the probe, which depends a lot on experienced sonographers. To this end, a flexible ultrasound scanning system (FUSS) is proposed to automatically image the human spine. In mechanics, a flexible fixture, fixed on the end joint of robotic arm, is designed to ensure the ultrasound probe to be pressed against the dorsal skin. Besides, decoupled control strategy is presented which decouples trajectory planning task and force control task into separate joint space. By this means, the possibility of accidental damage could be minimized Phantom experiments were carried out to validate the hysteresis characteristic of flexible fixture, the capacity to resisting impact, the performance of control system and the quality of reconstruction image. These results show that our system has high safety performance and could keep the probe force stable within the range of 1 N to obtain better reconstruction image than freehand scanning. In summary, it has a great potential on navigation of spine surgery.
引用
收藏
页码:426 / 435
页数:10
相关论文
共 50 条
  • [1] The Use of Intraoperative CT and Navigation for the Treatment of Spinal Deformity in Open and Minimally Invasive Surgery
    O'Brien, Joseph R.
    SPINE, 2017, 42 (07) : S28 - S29
  • [2] A Flexible and Fully Autonomous Breast Ultrasound Scanning System
    Tan, Jiyong
    Li, Bing
    Li, Yuanwei
    Li, Bin
    Chen, Xinxing
    Wu, Jiayi
    Luo, Baoming
    Leng, Yuquan
    Rong, Yiming
    Fu, Chenglong
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2023, 20 (03) : 1920 - 1933
  • [3] Characterization of a 6 DOF Acoustic-Inertial Navigation System for Minimally-Invasive Surgery
    Rapp, Philipp
    Haegele, Lena
    Sawodny, Oliver
    Tarin, Cristina
    2014 13TH INTERNATIONAL CONFERENCE ON CONTROL AUTOMATION ROBOTICS & VISION (ICARCV), 2014, : 1823 - 1828
  • [4] Minimally Invasive Surgery for Thoracolumbar Spinal Fractures in Patients With Ankylosing Spondylitis
    Wanman, Johan
    Burmeister, Fabian
    Thorell, David
    Kyrk, Tobias
    Blixt, Simon
    Gerdhem, Paul
    Mukka, Sebastian
    Bobinski, Lukas
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2023, 17 (04) : 1 - 8
  • [5] Self-Adaptive Ultrasound Scanning System for Imaging Human Spine
    Zhang, Jingyu
    Liu, Tianjian
    Wang, Yunjiang
    Jiang, Weiwei
    Yang, Keji
    Jin, Haoran
    Zhu, Yongjian
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (01) : 570 - 581
  • [6] An External Force Sensing System for Minimally Invasive Robotic Surgery
    Fontanelli, Giuseppe Andrea
    Buonocore, Luca Rosario
    Ficuciello, Fanny
    Villani, Luigi
    Siciliano, Bruno
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2020, 25 (03) : 1543 - 1554
  • [7] Robotics in minimally invasive surgery
    Grimbergen, CA
    Jaspers, JEN
    2004 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN & CYBERNETICS, VOLS 1-7, 2004, : 2486 - 2491
  • [8] Mechanical Design and Control Method of a Hollow Modular Joint for Minimally Invasive Spinal Surgery
    Song, Guoli
    Hou, Che
    Zhao, Yiwen
    Zhao, Xingang
    Han, Jianda
    INTERNATIONAL JOURNAL OF HUMANOID ROBOTICS, 2018, 15 (04)
  • [9] Design of robot control system for minimally invasive surgery of knee joint
    Shen, Haiming
    PROCEEDINGS OF 2018 IEEE 3RD ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC 2018), 2018, : 2583 - 2586
  • [10] Minimally invasive iridocorneal angle surgery
    Jordan, J. F.
    OPHTHALMOLOGE, 2012, 109 (07): : 713 - 723