Correlation between cord blood, perinatal BNP values and echocardiographic parameters in healthy Italian newborns

被引:17
|
作者
Mannarino, Savina [2 ]
Ciardelli, Laura [1 ]
Garofoli, Francesca [1 ]
Perotti, Gianfranco [3 ]
Mongini, Elisa [4 ]
Damiano, Simona [4 ]
Tinelli, Carmine [5 ]
Cerbo, Rosa Maria [3 ]
Rondini, Giorgio [4 ]
Stronati, Mauro [3 ]
机构
[1] Fdn IRCCS Policlin San Matteo, Lab Immunol Neonatale, Res Labs, I-27100 Pavia, Italy
[2] Fdn IRCCS Policlin San Matteo, Dept Paediat, I-27100 Pavia, Italy
[3] Fdn IRCCS Policlin San Matteo, Neonatal Intens Care Unit, I-27100 Pavia, Italy
[4] Fdn IRCCS Policlin San Matteo, Neonatol Unit, I-27100 Pavia, Italy
[5] Fdn IRCCS Policlin San Matteo, Biometr Unit, I-27100 Pavia, Italy
关键词
BNP; Newborns; Echocardiography; Cord blood; BRAIN NATRIURETIC PEPTIDE; VOLUME OVERLOAD; HEART-FAILURE; PLASMA-LEVELS; CHILDREN; INFANTS; DIAGNOSIS;
D O I
10.1016/j.earlhumdev.2008.05.008
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
We evaluated the correlation between brain natriuretic peptide (BNP) in umbilical cord blood after normal pregnancy, in blood samples of twenty-nine Italian healthy newborns and paired echocardiographic parameters. Plasma BNP was evaluated in UCB (T0) and in blood on day 3 (T1), 30 (T2) of life. Echocardiographic parameters were recorded at T1 and T2. Median of BNP concentrations in cord blood was 8.6 pg/ml. Median BNP concentrations on T1 was 59.2 pg/ml, on T2 was 8.7 pg/ml. Significantly higher BNP concentrations were reported on T1 than T0 and T2 (p<0.0001), while no significant difference resulted between TO and T2. Plasma BNP at T2 was significantly correlated with mVTI (p=0.006), E wave (p=0.004), LA (p=0.047), LVPW (p=0.004), M (p=0.025). No correlation was found with SF% and E/A. Our results confirm that in healthy and term neonates the cord blood BNP concentrations are low. On T1 BNP values are high with wide ranges because of physiological adjustment to postnatal circulation. When echocardiographic parameters are in normal ranges, BNP concentrations return to low levels on day 30. In healthy newborns left ventricular fitting, LA size and M seem to influence BNP levels rather than left ventricular systolic and diastolic function. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:13 / 17
页数:5
相关论文
共 50 条
  • [1] Correlation between BNP Levels and Doppler Echocardiographic Parameters of Left Ventricle Filling Pressure in Patients with Chagasic Cardiomyopathy
    Oliveira, Braulio M. R.
    Botoni, Fernando A.
    Ribeiro, Antonio L. P.
    Pinto, Airandes S.
    Reis, Adelina M.
    Nunes, Maria do Carmo P.
    Rocha, Manoel O. C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (05): : 521 - 527
  • [2] Correlation between echocardiographic findings and biochemical markers in term newborns with moderate to severe perinatal asphyxia
    Vasiljevic, Milena
    Nesic, Dejan
    Krasic, Stasa
    Ninic, Sanja
    Prijic, Sergej
    Asanin, Milika
    Stankovic, Sanja
    Cerovic, Ivana
    Milicevic, Srboljub
    Knezevic-Rangelov, Sanja
    Vukomanovic, Vladislav
    ARCHIVES OF BIOLOGICAL SCIENCES, 2021, 73 (02) : 175 - 183
  • [3] Blood pressure values in healthy term newborns at a tertiary health facility in Enugu, Nigeria
    Nwokoye, I. C.
    Uleanya, N. D.
    Ibeziako, N. S.
    Ikefuna, A. N.
    Eze, J. C.
    Ibe, J. C.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2015, 18 (05) : 584 - 588
  • [4] Reference values of leukocyte and lymphocytes populations in umbilical cord and capillary blood in healthy Mexican newborns
    Scheffer-Mendoza, S.
    Espinosa-Padilla, S. E.
    Lopez-Herrera, G.
    Mujica-Guzman, F.
    Lopez-Padilla, M. G.
    Berron-Ruiz, L.
    ALLERGOLOGIA ET IMMUNOPATHOLOGIA, 2020, 48 (03) : 295 - 305
  • [5] Correlation between cord blood bilirubin level and incidence of hyperbilirubinemia in term newborns
    Satrya, Rudy
    Effendi, Sjarif Hidayat
    Gurnida, Dida Alchtnad
    PAEDIATRICA INDONESIANA, 2009, 49 (06) : 349 - 354
  • [6] Doppler echocardiographic assessment of pulmonary blood flow in healthy newborns
    Gournay, V
    Cambonie, G
    Rozé, JC
    ACTA PAEDIATRICA, 1998, 87 (04) : 419 - 423
  • [7] The influence of cord blood renalase and advanced oxidation protein products (AOPPs) on perinatal and anthropometric parameters of newborns of mothers with gestational hypertension
    Czubilinska-Lada, Justyna
    Badenski, Andrzej
    Swietochowska, Elzbieta
    Nowak-Borzecka, Lucyna
    Sadownik, Beata
    Behrendt, Jakub
    Szczepanska, Maria
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 31 (09): : 973 - 979
  • [8] Prediction of perinatal asphyxia with nucleated red blood cells in cord blood of newborns
    Ghosh, B
    Mittal, S
    Kumar, S
    Dadhwal, V
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2003, 81 (03) : 267 - 271
  • [9] Are Cord Blood Bilirubin Values Trustable to Predict the Forthcoming Significant Hyperbilirubinemia Requiring Treatment in Healthy Term Newborns?
    Bijari, Bahareh Bahman
    Jamali, Zahra
    Niknafs, Pedram
    Norouzi, Elaheh
    Mosayi, Hamid
    Mohit, Maryam
    Baneshi, Mohammad Reza
    Shahriari, Zahra
    Amiresmaeili, Habibeh
    IRANIAN JOURNAL OF PEDIATRICS, 2019, 29 (04)
  • [10] Cord blood lipid profile in healthy newborns: A prospective single-center study
    Pac-Kozuchowska, Elzbieta
    Rakus-Kwiatosz, Anna
    Krawiec, Paulina
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 27 (03): : 343 - 349