Viability assessment and utilization of declined donor kidneys with rhabdomyolysis using ex vivo normothermic perfusion without preimplantation biopsy

被引:2
|
作者
Pearson, Robert [1 ]
Asher, John [1 ]
Jackson, Andrew [1 ]
Mark, Patrick B. [1 ]
Shumeyko, Vlad [1 ]
Clancy, Marc J. [1 ]
机构
[1] Queen Elizabeth Univ Hosp, Glasgow, Lanark, Scotland
关键词
DECEASED DONORS; TRANSPLANTATION; INJURY; SURVIVAL; OUTCOMES;
D O I
10.1111/ajt.16329
中图分类号
R61 [外科手术学];
学科分类号
摘要
The role of ex vivo normothermic perfusion (EVNP) in both organ viability assessment and reconditioning is increasingly being demonstrated. We report the use of this emerging technology to facilitate the transplantation of a pair of donor kidneys with severe acute kidney injury (AKI) secondary to rhabdomyolysis. Donor creatinine was 10.18 mg/dl with protein (30 mg/dl) present in urinalysis. Both kidneys were declined by all other transplantation units and subsequently accepted by our unit. The first kidney was perfused with red cell-based perfusate at 37 degrees C for 75 min, mean renal blood flow was 110 ml/min/100 g and produced 85 ml of urine. Having demonstrated favorable macroscopic appearance and urine output, the kidney was transplanted into a 61-year-old peritoneal dialysis dependent without complication. Given the reassuring information from the first kidney provided by EVNP, the second kidney was not perfused with EVNP and was directly implanted to a 64-year-old patient. The first kidney achieved primary function and the second functioned well after delayed graft function. Recipient eGFR have stabilized at 88.5 and 55.3, respectively (ml/min/1.73 m(2)), at 2 months posttransplant.
引用
收藏
页码:1317 / 1321
页数:5
相关论文
共 50 条
  • [31] Use of Ex Vivo Normothermic Perfusion for Quality Assessment of Discarded Human Donor Pancreases
    Barlow, A. D.
    Hamed, M. O.
    Mallon, D. H.
    Brais, R. J.
    Gribble, F. M.
    Scott, M. A.
    Howat, W. J.
    Bradley, J. A.
    Bolton, E. M.
    Pettigrew, G. J.
    Hosgood, S. A.
    Nicholson, M. L.
    Saeb-Parsy, K.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2015, 15 (09) : 2475 - 2482
  • [32] Successful Ex-Vivo Normothermic Machine Perfusion and Viability Testing of Discarded Human Donor Livers
    op den Dries, S.
    Karimian, N.
    Sutton, M.
    Westerkamp, A.
    Nijsten, M.
    Gouw, A.
    Wiersema-Buist, J.
    Lisman, T.
    Leuvenink, H.
    Porte, R.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2013, 13 : 519 - 519
  • [33] Successful ex-vivo normothermic machine perfusion and viability testing of discarded human donor livers
    den Dries, Sanna Op
    Karimian, Negin
    Sutton, Michael E.
    Westerkamp, Andrie
    Nijsten, Maarten
    Gouw, Annette S.
    Wiersema-Buist, Janneke
    Lisman, Ton
    Leuvenink, Henri G.
    Porte, Robert J.
    HEPATOLOGY, 2012, 56 (06) : 1527 - 1527
  • [34] SUCCESSFUL EX-VIVO NORMOTHERMIC MACHINE PERFUSION AND VIABILITY TESTING OF DISCARDED HUMAN DONOR LIVERS
    Op den Dries, Sanna
    Karimian, Negin
    Sutton, Michael E.
    Westerkamp, Andrie C.
    Nijsten, Maarten W. N.
    Gouw, Annet S. H.
    Wiersema-Buist, Janneke
    Lisman, Ton
    Leuvenink, Henri G. D.
    Porte, Robert J.
    TRANSPLANT INTERNATIONAL, 2013, 26 : 337 - 337
  • [35] The use of ex-vivo normothermic perfusion for the resuscitation and assessment of human kidneys discarded because of inadequate in situ perfusion
    Hosgood, Sarah A.
    Barlow, A. D.
    Dormer, J.
    Nicholson, M. L.
    JOURNAL OF TRANSLATIONAL MEDICINE, 2015, 13
  • [36] QUALITY ASSESSMENT OF DISCARDED HUMAN KIDNEYS: A COMPARISON OF HYPOTHERMIC MACHINE PERFUSION AND EX-VIVO NORMOTHERMIC PERFUSION TECHNIQUES
    Hosgood, S.
    Nicholson, M.
    TRANSPLANT INTERNATIONAL, 2016, 29 : 14 - 14
  • [37] FUNCTIONAL MRI ASSESSMENT DURING EX VIVO NORMOTHERMIC PERFUSION: THE FIRST EXPERIENCE WITH DISCARDED HUMAN KIDNEYS
    Hamelink, Tim
    Lantinga, Veerle A.
    Schutter, Rianne
    Ogurlu, Baran
    Potze, Jan Hendrik
    Leuvenink, Henri
    Borra, Ronald
    Moers, Cyril
    TRANSPLANT INTERNATIONAL, 2021, 34 : 272 - 272
  • [38] Quality assessment of discarded human kidneys: a comparison of hypothermic machine perfusion and ex-vivo normothermic perfusion techniques
    Hosgood, S.
    Barlow, A.
    Nicholson, M.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 26 - 26
  • [39] The use of ex-vivo normothermic perfusion for the resuscitation and assessment of human kidneys discarded because of inadequate in situ perfusion
    Sarah A. Hosgood
    A. D. Barlow
    J. Dormer
    M. L. Nicholson
    Journal of Translational Medicine, 13
  • [40] 26-hour Storage of a Declined Liver Before Successful Transplantation Using Ex Vivo Normothermic Perfusion
    Watson, Christopher J. E.
    Kosmoliaptsis, Lucy V. Randle Vasilis
    Gibbs, Paul
    Allison, Michael
    Butler, Andrew J.
    ANNALS OF SURGERY, 2017, 265 (01) : E1 - E2