Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants

被引:43
|
作者
Harb, Samarah, V [1 ]
Bassous, Nicole J. [2 ]
de Souza, Thiago A. C. [1 ]
Trentin, Andressa [1 ]
Pulcinelli, Sandra H. [1 ]
Santilli, Celso, V [1 ]
Webster, Thomas J. [2 ]
Lobo, Anderson O. [3 ]
Hammer, Peter [1 ]
机构
[1] Sao Paulo State Univ, Inst Chem, UNESP, BR-14800060 Araraquara, SP, Brazil
[2] Northeastern Univ, Dept Chem Engn, Boston, MA 02115 USA
[3] Fed Univ Piaui UFPI, Dept Mat Engn, Interdisciplinary Lab Adv Mat LIMAV, BR-64049550 Teresina, PI, Brazil
基金
巴西圣保罗研究基金会;
关键词
Organic-inorganic hybrid; Nanocomposite coating; Corrosion protection; Bioactive coating; Ti6Al4V alloy; IN-VITRO BIOCOMPATIBILITY; SURFACE-MODIFIED TI6AL4V; SOL-GEL; PMMA/TIO2; NANOCOMPOSITES; IMPROVED OSTEOBLAST; TITANIUM SURFACES; STAINLESS-STEEL; HYBRID; ADHESION; ALLOY;
D O I
10.1016/j.msec.2020.111149
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Organic-inorganic hybrid coatings deposited on different types of metallic alloys have shown outstanding anticorrosive performance. The incorporation of osteoconductive additives such as hydroxyapatite (HA) and beta-tricalcium phosphate (beta-TCP) into organic-inorganic hybrid coatings is promising to improve the osseointe-gration and corrosion resistance of Ti6Al4V alloys, which are the most widely used metallic orthopedic and dental implant materials today. Therefore, this study evaluated the capability of poly(methyl methacrylate) (PMMA)-TiO2 and PMMA-ZrO2 hybrid coatings modified with HA and beta-TCP to act as bioactive and corrosion protection coatings for Ti6Al4V alloys. In terms of cell growth and mineralization, osteoblast viability, Ca+2 deposition and alkaline phosphatase assays revealed a significant improvement for the HA and beta-TCP modified coatings, compared to the bare alloy. This can be explained by an increase in nanoscale roughness and associated higher surface free energy, which lead to enhanced protein adsorption to promote osteoblast attachment and functions on the coatings. The effect of HA and beta-TCP additives on the anticorrosive efficiency was studied by electrochemical impedance spectroscopy (EIS) in a simulated body fluid (SBF) solution. The coatings presented a low-frequency impedance modulus of up to 430 G Omega cm(2) , 5 decades higher than the bare Ti6Al4V alloy. These findings provide clear evidence of the beneficial role of HA and beta-TCP modified hybrid coatings, improving both the biocompatibility and corrosion resistance of the Ti6Al4V alloy.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Effect of ZrO2 particle on the performance of micro-arc oxidation coatings on Ti6Al4V
    Li, Hong
    Sun, Yezi
    Zhang, Jin
    APPLIED SURFACE SCIENCE, 2015, 342 : 183 - 190
  • [42] The structure and corrosion resistance of the surface modified Ti6Al4V alloy
    Stypula, Barbara
    Janus, Marta
    OCHRONA PRZED KOROZJA, 2009, 52 (11): : 548 - 550
  • [43] In vitro assessment of the biological response of Ti6Al4V implants coated with hydroxyapatite microdomains
    Salvador Clavell, R.
    Martin de Llano, J. J.
    Carda, C.
    Gomez Ribelles, J. L.
    Valles-Lluch, A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2016, 104 (11) : 2723 - 2729
  • [44] In-Situ Synthesis and Characterization of Chitosan/Hydroxyapatite Nanocomposite Coatings to Improve the Bioactive Properties of Ti6Al4V Substrates
    Ansari, Zahra
    Kalantar, Mahdi
    Soriente, Alessandra
    Fasolino, Ines
    Kharaziha, Mahshid
    Ambrosio, Luigi
    Raucci, Maria Grazia
    MATERIALS, 2020, 13 (17)
  • [45] High temperature oxidation behavior of TiO2 + ZrO2 composite ceramic coatings prepared by microarc oxidation on Ti6Al4V alloy
    Wang, Chao
    Hao, Jianmin
    Xing, Yazhe
    Guo, Chaofei
    Chen, Hong
    SURFACE & COATINGS TECHNOLOGY, 2015, 261 : 201 - 207
  • [46] Synthesis and Characterization of PMMA-ZrO2 (SiO2, TiO2, Al2O3) Organic-Inorganic Hybrid Materials
    Jiang Kuiyang
    Zhang Jun
    Gui Linlin
    ACTA PHYSICO-CHIMICA SINICA, 1997, 13 (05) : 407 - 412
  • [47] The Effect of Coating Thickness on Corrosion Resistance of Hydroxyapatite Coated Ti6Al4V and 316L SS Implants
    Aksakal, B.
    Gavgali, M.
    Dikici, B.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2010, 19 (06) : 894 - 899
  • [48] The Effect of Coating Thickness on Corrosion Resistance of Hydroxyapatite Coated Ti6Al4V and 316L SS Implants
    B. Aksakal
    M. Gavgali
    B. Dikici
    Journal of Materials Engineering and Performance, 2010, 19 : 894 - 899
  • [49] Characterization of TiO2 nanotube formation on additively manufactured Ti6Al4V surfaces for medical implants
    Goli, Majid
    Shahrebabaki, Kimia Eslami
    Mehrnoush, Sharareh
    Labbaf, Sheyda
    JOURNAL OF MATERIALS RESEARCH, 2025, : 622 - 636
  • [50] Corrosion and Oxidation Protection of Ti6Al4V Alloy by an Inorganic Metal Modified Silicate Composite Coating
    Wang, Cheng
    Zhu, Shenglong
    Wang, Fuhui
    PRICM 7, PTS 1-3, 2010, 654-656 : 1952 - 1955