Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants

被引:43
|
作者
Harb, Samarah, V [1 ]
Bassous, Nicole J. [2 ]
de Souza, Thiago A. C. [1 ]
Trentin, Andressa [1 ]
Pulcinelli, Sandra H. [1 ]
Santilli, Celso, V [1 ]
Webster, Thomas J. [2 ]
Lobo, Anderson O. [3 ]
Hammer, Peter [1 ]
机构
[1] Sao Paulo State Univ, Inst Chem, UNESP, BR-14800060 Araraquara, SP, Brazil
[2] Northeastern Univ, Dept Chem Engn, Boston, MA 02115 USA
[3] Fed Univ Piaui UFPI, Dept Mat Engn, Interdisciplinary Lab Adv Mat LIMAV, BR-64049550 Teresina, PI, Brazil
基金
巴西圣保罗研究基金会;
关键词
Organic-inorganic hybrid; Nanocomposite coating; Corrosion protection; Bioactive coating; Ti6Al4V alloy; IN-VITRO BIOCOMPATIBILITY; SURFACE-MODIFIED TI6AL4V; SOL-GEL; PMMA/TIO2; NANOCOMPOSITES; IMPROVED OSTEOBLAST; TITANIUM SURFACES; STAINLESS-STEEL; HYBRID; ADHESION; ALLOY;
D O I
10.1016/j.msec.2020.111149
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Organic-inorganic hybrid coatings deposited on different types of metallic alloys have shown outstanding anticorrosive performance. The incorporation of osteoconductive additives such as hydroxyapatite (HA) and beta-tricalcium phosphate (beta-TCP) into organic-inorganic hybrid coatings is promising to improve the osseointe-gration and corrosion resistance of Ti6Al4V alloys, which are the most widely used metallic orthopedic and dental implant materials today. Therefore, this study evaluated the capability of poly(methyl methacrylate) (PMMA)-TiO2 and PMMA-ZrO2 hybrid coatings modified with HA and beta-TCP to act as bioactive and corrosion protection coatings for Ti6Al4V alloys. In terms of cell growth and mineralization, osteoblast viability, Ca+2 deposition and alkaline phosphatase assays revealed a significant improvement for the HA and beta-TCP modified coatings, compared to the bare alloy. This can be explained by an increase in nanoscale roughness and associated higher surface free energy, which lead to enhanced protein adsorption to promote osteoblast attachment and functions on the coatings. The effect of HA and beta-TCP additives on the anticorrosive efficiency was studied by electrochemical impedance spectroscopy (EIS) in a simulated body fluid (SBF) solution. The coatings presented a low-frequency impedance modulus of up to 430 G Omega cm(2) , 5 decades higher than the bare Ti6Al4V alloy. These findings provide clear evidence of the beneficial role of HA and beta-TCP modified hybrid coatings, improving both the biocompatibility and corrosion resistance of the Ti6Al4V alloy.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Bioactive response of PMMA coating obtained by electrospinning on ISO5832-9 and Ti6Al4V biomaterials
    Camargo, Eliziane R.
    Serafim, Bruno M.
    da Cruz, Anderson F.
    Soares, Paulo
    de Oliveira, Carolina C.
    Saul, Cyro K.
    Marino, Claudia E. B.
    SURFACE & COATINGS TECHNOLOGY, 2021, 412
  • [22] Corrosion behavior and biocompatibility of nanostructured TiO2 film on Ti6Al4V
    Karpagavalli, Ramji
    Zhou, Anhong
    Chellamuthu, Prithiviraj
    Nguyen, Kytai
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 83A (04) : 1087 - 1095
  • [23] Dipcoating of poly (ε-caprolactone)/hydroxyapatite composite coating on Ti6Al4V for enhanced corrosion protection
    Yusoff, Mohd Faiz Mohd
    Kadir, Mohammed Rafiq Abdul
    Iqbal, Nida
    Hassan, Mas Ayu
    Hussain, Rafaqat
    SURFACE & COATINGS TECHNOLOGY, 2014, 245 : 102 - 107
  • [24] Surface Modification of TiO2 Nanotubes with Bioactive Molecules to Improve the Osteocompatibility of Ti6Al4V based Bone Implants
    Saha, S.
    TISSUE ENGINEERING PART A, 2017, 23 : S54 - S54
  • [25] Chitosal/hydroxyapatite composite coatings on porous Ti6Al4V titanium implants: in vitro and in vivo studies
    Zhang, Ting
    Zhang, Xinwei
    Mao, Mengyun
    Li, Jiayi
    Wei, Ting
    Sun, Huiqiang
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2020, 50 (06): : 392 - 405
  • [26] Strontium doped hydroxyapatite biomimetic coatings on Ti6Al4V plates
    Avci, Muhammed
    Yilmaz, Bengi
    Tezcaner, Aysen
    Evis, Zafer
    CERAMICS INTERNATIONAL, 2017, 43 (12) : 9431 - 9436
  • [27] FEM assisted evaluation of PMMA and Ti6Al4V as materials for cranioplasty resulting mechanical behaviour and the neurocranial protection
    Tsouknidas, Alexander
    Maropoulos, Stergios
    Savvakis, Savvas
    Michailidis, Nikolaos
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2011, 21 (03) : 139 - 147
  • [28] Scratch resistance and electrochemical corrosion behavior of hydroxyapatite coatings on Ti6Al4V in simulated physiological media
    T. Roland
    H. Pelletier
    J. Krier
    Journal of Applied Electrochemistry, 2013, 43 : 53 - 63
  • [29] Scratch resistance and electrochemical corrosion behavior of hydroxyapatite coatings on Ti6Al4V in simulated physiological media
    Roland, T.
    Pelletier, H.
    Krier, J.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2013, 43 (01) : 53 - 63
  • [30] Blood Compatibility of ZrO2 Particle Reinforced PEEK Coatings on Ti6Al4V Substrates
    Song, Jian
    Liao, Zhenhua
    Shi, Hongyu
    Xiang, Dingding
    Xu, Lin
    Liu, Yuhong
    Mu, Xiaohong
    Liu, Weiqiang
    POLYMERS, 2017, 9 (11)