A novel muscle biopsy clamp yields accurate in vivo sarcomere length values

被引:21
作者
Ward, Samuel R. [1 ,2 ,3 ]
Takahashi, Mitsuhiko [2 ]
Winters, Taylor M. [2 ,4 ]
Kwan, Alan [2 ,4 ]
Lieber, Richard L. [2 ,4 ]
机构
[1] Vet Adm Med Ctr, Dept Radiol & Orthopaed Surg 9151, San Diego, CA 92161 USA
[2] Univ Calif San Diego, Dept Orthopaed Surg, San Diego, CA 92161 USA
[3] Univ Calif San Diego, Dept Radiol, San Diego, CA 92161 USA
[4] Univ Calif San Diego, Dept Bioengn, San Diego, CA 92161 USA
关键词
Laser diffraction; Muscle architecture; Muscle function; Sarcomere length; Muscle biopsy; MYOFASCIAL FORCE TRANSMISSION; SKELETAL-MUSCLE; DIFFRACTION PATTERNS; FROG SARTORIUS; HINDLIMB; CONTRACTION; POSITION; BEHAVIOR; TENSION; FIBERS;
D O I
10.1016/j.jbiomech.2008.10.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The measurement of in vivo Muscle sarcomere length facilitates the definition of in vivo muscle functional properties and comparison of muscle designs amongst functional muscle groups. In vivo sarcomere lengths are available for just a handful of human muscles, largely due to the technical challenges associated with their measurement. The purpose or this report was to develop and test a Muscle biopsy clamp that can quickly and accurately measure in Vivo Muscle sarcomere length. To test the device, muscle biopsies (n = 23) were removed from the tibialis anterior muscles of New Zealand White rabbits immediately after sarcomere length measurements were made using laser diffraction. The muscle biopsy contained within the clamp was immediately fixed in Formalin for subsequent sarcomere length measurement. Comparisons of clamp-based and diffraction-based sarcomere lengths demonstrated excellent agreement between the two techniques, especially when the biopsy was obtained at relatively long lengths (above 2.6 mu m). Given the intraoperative speed and simplicity of this technique and the relatively low-cost of the biopsy clamp, this method of measuring muscle sarcomere length should help investigators generate much-needed in vivo muscle structural and functional data. Published by Elsevier Ltd.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 22 条
  • [1] A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii
    Blemker, SS
    Pinsky, PM
    Delp, SL
    [J]. JOURNAL OF BIOMECHANICS, 2005, 38 (04) : 657 - 665
  • [2] Three-dimensional representation of complex muscle architectures and geometries
    Blemker, SS
    Delp, SL
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (05) : 661 - 673
  • [3] ARCHITECTURAL, HISTOCHEMICAL, AND CONTRACTILE CHARACTERISTICS OF A UNIQUE BIARTICULAR MUSCLE - THE CAT SEMI-TENDINOSUS
    BODINE, SC
    ROY, RR
    MEADOWS, DA
    ZERNICKE, RF
    SACKS, RD
    FOURNIER, M
    EDGERTON, VR
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 1982, 48 (01) : 192 - 201
  • [4] CLEWORTH DR, 1972, J PHYSIOL-LONDON, V227, P1
  • [5] RELIABILITY AND VALIDITY OF GONIOMETRIC MEASUREMENTS AT THE KNEE
    GOGIA, PP
    BRAATZ, JH
    ROSE, SJ
    NORTON, BJ
    [J]. PHYSICAL THERAPY, 1987, 67 (02): : 192 - 195
  • [6] FORCE-LENGTH RELATION OF INVIVO HUMAN RECTUS FEMORIS MUSCLES
    HERZOG, W
    TERKEURS, HEDJ
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1988, 411 (06): : 642 - 647
  • [7] MAXIMUM LENGTH FOR CONTRACTION IN VERTEBRATE STRIATED MUSCLE
    HUXLEY, AF
    PEACHEY, LD
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (01): : 150 - &
  • [8] SARCOMERE-LENGTH AND JOINT KINEMATICS DURING TORQUE PRODUCTION IN FROG HINDLIMB
    LIEBER, RL
    BOAKES, JL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (06): : C759 - C768
  • [9] IN-VIVO MEASUREMENT OF HUMAN WRIST EXTENSOR MUSCLE SARCOMERE-LENGTH CHANGES
    LIEBER, RL
    LOREN, GJ
    FRIDEN, J
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 1994, 71 (03) : 874 - 881
  • [10] SARCOMERE-LENGTH DETERMINATION USING LASER DIFFRACTION - EFFECT OF BEAM AND FIBER DIAMETER
    LIEBER, RL
    YEH, Y
    BASKIN, RJ
    [J]. BIOPHYSICAL JOURNAL, 1984, 45 (05) : 1007 - 1016