Techniques for temperature monitoring during laser-induced thermotherapy: An overview

被引:176
作者
Saccomandi, Paola [1 ]
Schena, Emiliano [1 ]
Silvestri, Sergio [1 ]
机构
[1] Univ Campus Biomed Roma, Ctr Integrated Res, Unit Measurements & Biomed Instrumentat, I-00128 Rome, Italy
关键词
CT thermometry; fibre-optic sensors; laser ablation; MRI thermometry; thermotherapy; INDUCED INTERSTITIAL THERMOTHERAPY; EX-VIVO; COMPUTED-TOMOGRAPHY; NONINVASIVE THERMOMETRY; MEASUREMENT ARTIFACTS; TISSUE TEMPERATURE; FREQUENCY-SHIFT; ABLATION; LIVER; FEASIBILITY;
D O I
10.3109/02656736.2013.832411
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Laser-induced thermotherapy (LITT) is a hyperthermic procedure recently employed to treat cancer in several organs. The amount of coagulated tissue depends on the temperature distribution around the applicator, which plays a crucial role for an optimal outcome: the removal of the whole neoplastic tissue, whilst preventing damage to the surrounding healthy tissue. Although feedback concerning tissue temperature could be useful to drive the physician in the adjustment of laser settings and treatment duration, LITT is usually performed without real-time monitoring of tissue temperature. During recent decades, many thermometric techniques have been developed to be used during thermal therapies. This paper provides an overview of techniques and sensors employed for temperature measurement during tissue hyperthermia, focusing on LITT, and an investigation of their performances in this application. The paper focuses on the most promising and widespread temperature monitoring techniques, splitting them into two groups: the former includes invasive techniques based on the use of thermocouples and fibre-optic sensors; the second analyses non-invasive methods, i.e. magnetic resonance imaging-, computerised tomography-and ultrasound-based thermometry. Background information on measuring principle, medical applications, advantages and weaknesses of each method are provided and discussed.
引用
收藏
页码:609 / 619
页数:11
相关论文
共 82 条
  • [1] [Anonymous], 2019, Diagnostic Ultrasound, Physics and Equipment
  • [2] EFFECTS OF SURFACE IRRIGATION ON THE THERMAL RESPONSE OF TISSUE DURING LASER IRRADIATION
    ANVARI, B
    MOTAMEDI, M
    TORRES, JH
    RASTEGAR, S
    ORIHUELA, E
    [J]. LASERS IN SURGERY AND MEDICINE, 1994, 14 (04) : 386 - 395
  • [3] Bazrafshan B, 1984, LASER MED SCI, V31, P161
  • [4] RELAXATION EFFECTS IN NUCLEAR MAGNETIC RESONANCE ABSORPTION
    BLOEMBERGEN, N
    PURCELL, EM
    POUND, RV
    [J]. PHYSICAL REVIEW, 1948, 73 (07): : 679 - 712
  • [5] Bowen T., 1979, Ultrasonic Tissue Characterisation II, P57
  • [6] PROBE FOR MEASURING TEMPERATURE IN RADIO-FREQUENCY-HEATED MATERIAL
    BOWMAN, RR
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1976, 24 (01) : 43 - 45
  • [7] CT-based temperature monitoring during hepatic RF ablation: Feasibility in an animal model
    Bruners, Philipp
    Pandeya, Ganga D.
    Levit, Elena
    Roesch, Eva
    Penzkofer, Tobias
    Isfort, Peter
    Schmidt, Bernhardt
    Greuter, Marcel J. W.
    Oudkerk, Matthijs
    Schmitz-Rode, Thomas
    Kuhl, Christiane K.
    Mahnken, Andreas H.
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2012, 28 (01) : 55 - 61
  • [8] Multi-slice computed tomography: A tool for non-invasive temperature measurement?
    Bruners, Philipp
    Levit, Elena
    Penzkofer, Tobias
    Isfort, Peter
    Ocklenburg, Christina
    Schmidt, Bernhardt
    Schmitz-Rode, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2010, 26 (04) : 359 - 365
  • [9] TEMPERATURE-DEPENDENCE OF COMPUTED-TOMOGRAPHY ATTENUATION VALUES
    BYDDER, GM
    KREEL, L
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (04) : 506 - 510
  • [10] THIN-FILM TEMPERATURE SENSORS FOR BIOLOGICAL MEASUREMENTS
    CAIN, CP
    WELCH, AJ
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1974, BM21 (05) : 421 - 423