Flow injection spectrophotometric or conductometric determination of ascorbic acid in a vitamin C tablet using permanganate or ammonia

被引:56
作者
Grudpan, K [1 ]
Kamfoo, K [1 ]
Jakmunee, J [1 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Chiang Mai 50200, Thailand
关键词
ascorbic acid; vitamin C; flow injection; spectrophotometry; conductometry; permanganate; ammonia;
D O I
10.1016/S0039-9140(99)00047-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two simple flow injection (FI) procedures for the determination of ascorbic acid content in a vitamin C tablet are proposed: spectrophotometric involving injection into a stream of acidic potassium permanganate solution and monitoring its color change due to the redox reaction; Fl conductometry based on the neutralization of ascorbic acid injected into a flowing ammonia solution yielding a change in conductivity. The procedures have been applied to the analysis of locally commercial vitamin C tablet samples. A through-put of at least 90 injections h(-1) can be achieved. The relative standard deviation was found to be 2.5% (for a 50 mg vitamin C tablet; n = 7) for both. Results obtained by either procedure agree with a standard titrimetric method. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1023 / 1026
页数:4
相关论文
共 15 条
[1]   IODIMETRIC DETERMINATION OF IODATE, BROMATE, HYPOCHLORITE, ASCORBIC-ACID AND THIOUREA USING FLOW-INJECTION AMPEROMETRY [J].
ABDALLA, MA ;
ALSWAIDAN, HM .
ANALYST, 1989, 114 (05) :583-586
[2]   DETERMINATION OF ASCORBIC-ACID IN PHARMACEUTICALS AND URINE BY REVERSE FLOW-INJECTION [J].
ALBERO, MI ;
GARCIA, MS ;
SANCHEZPEDRENO, C ;
RODRIGUEZ, J .
ANALYST, 1992, 117 (10) :1635-1638
[3]   DETERMINATION OF ASCORBIC-ACID BY FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION [J].
ALWARTHAN, AA .
ANALYST, 1993, 118 (06) :639-642
[4]  
[Anonymous], 1993, BRIT PHARMACOPOEIA
[5]   DETERMINATION OF ASCORBIC-ACID IN SOFT DRINKS AND FRUIT JUICES .1. BACKGROUND CORRECTION FOR DIRECT ULTRAVIOLET SPECTROPHOTOMETRY [J].
FUNG, YS ;
LUK, SF .
ANALYST, 1985, 110 (02) :201-204
[6]   DETERMINATION OF L-ASCORBIC-ACID IN FRUIT AND VEGETABLE JUICES BY FLOW-INJECTION WITH IMMOBILIZED ASCORBATE OXIDASE [J].
GREENWAY, GM ;
ONGOMO, P .
ANALYST, 1990, 115 (10) :1297-1299
[7]   FLOW-INJECTION ANALYSIS USING AN AQUARIUM AIR PUMP [J].
GRUDPAN, K ;
TAYLOR, C ;
SITTER, H ;
KELLER, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (10-11) :882-884
[8]   Flow injection conductimetric or spectrophotometric analysis for acidity in fruit juice [J].
Grudpan, K ;
Sritharathikhun, P ;
Jakmunee, J .
ANALYTICA CHIMICA ACTA, 1998, 363 (2-3) :199-202
[9]   RADIOMETRIC DETECTORS FOR FLOW-INJECTION ANALYSIS [J].
GRUDPAN, K ;
NACAPRICHA, D ;
WATTANAKANJANA, Y .
ANALYTICA CHIMICA ACTA, 1991, 246 (02) :325-328
[10]   Flow-injection spectrophotometric determination of calcium using murexide as a color agent [J].
Grudpan, K ;
Jakmunee, J ;
Vaneesorn, Y ;
Watanesk, S ;
Maung, UA ;
Sooksamiti, P .
TALANTA, 1998, 46 (06) :1245-1257