Late onset perinatal sepsis in the neonatology intensive care unit - risk factors

被引:0
作者
Dobric, Hana [1 ]
Milas, Vesna [1 ]
Milas, Kresimir [1 ]
机构
[1] Clin Hosp Ctr Osijek, Dept Neonatol, Osijek, Croatia
关键词
low-birth-weight pre-term infants; nosocomial infections; risk factors; umbilical venous catheters; NICU; PICC; mechanical ventilation; high-flow nasal cannula; FLOW NASAL CANNULA; NOSOCOMIAL INFECTIONS; SUPPORT;
D O I
10.22514/SV112.062016.12
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The lowest-birth-weight premature is very susceptible for nosocomial infections. These infants require the most invasive therapeutic interventions and the longest exposure to environment conductive for microbial colonization. Incidence of nosocomial infection and risk factors in premature has been compared over two years, 2010 and 2015. We examined the effects of common procedures on the incidence of nosocomial sepsis. Birth weight, distribution of pathogens and the therapeutically procedures had been analysed. We tried to find strategies to minimise the risks for acquiring sepsis. Hospital documentation from neonatal intensive care unit (NICU) has been analysed retrospectively during two different years in the University Hospital Osijek. Incidence of nosocomial sepsis among hospitalised premature has been 8.9% in 2010, and 4.8% in 2015. The highest rate of affected infants weighed below 1,500 g in both periods. Statistically significance in these two periods has been found in the percentage of pre-term infants with umbilical vein catheter (UVC), and in the number of pre-term on invasive mechanical ventilation. The most common pathogen in 2010 was methicillin-resistant Staphylococcus epidermidis (MRSE), and in 2015 coagulase negative Staphylococci (CONS). The percentage of Candida parapsylosis was higher in 2015. Lowering the incidence of late-onset sepsis has been accomplished by using peripherally inserted central catheters (PICCs) and non-invasive mechanical ventilation. Invasive procedures must be avoided as much as possible.
引用
收藏
页码:57 / 60
页数:4
相关论文
共 26 条
  • [21] Reduced intubation rates for infants after introduction of high-flow nasal prong oxygen delivery
    Schibler, A.
    Pham, T. M. T.
    Dunster, K. R.
    Foster, K.
    Barlow, A.
    Gibbons, K.
    Hough, J. L.
    [J]. INTENSIVE CARE MEDICINE, 2011, 37 (05) : 847 - 852
  • [22] Stoll JB, 2002, LATE ONSET SEPSIS VE, V110
  • [23] The impact of hospital-acquired bloodstream infections
    Wenzel, RP
    Edmond, MB
    [J]. EMERGING INFECTIOUS DISEASES, 2001, 7 (02) : 174 - 177
  • [24] Use of High-Flow Nasal Cannula Support in the Emergency Department Reduces the Need for Intubation in Pediatric Acute Respiratory Insufficiency
    Wing, Robyn
    James, Catherine
    Maranda, Louise S.
    Armsby, Carrie C.
    [J]. PEDIATRIC EMERGENCY CARE, 2012, 28 (11) : 1117 - 1123
  • [25] Yang Ling-Rong, 2013, Zhongguo Dang Dai Er Ke Za Zhi, V15, P112
  • [26] Heated, Humidified High-Flow Nasal Cannula Versus Nasal CPAP for Respiratory Support in Neonates
    Yoder, Bradley A.
    Stoddard, Ronald A.
    Li, Ma
    King, Jerald
    Dirnberger, Daniel R.
    Abbasi, Soraya
    [J]. PEDIATRICS, 2013, 131 (05) : E1482 - E1490