Liquid AP-UV-MALDI Enables Stable Ion Yields of Multiply Charged Peptide and Protein Ions for Sensitive Analysis by Mass Spectrometry

被引:62
作者
Cramer, Rainer [1 ,3 ]
Pirkl, Alexander [2 ,3 ]
Hillenkamp, Franz [3 ]
Dreisewerd, Klaus [2 ,3 ]
机构
[1] Univ Reading, Dept Chem, Reading RG6 6AD, Berks, England
[2] Univ Munster, Inst Hyg, D-48149 Munster, Germany
[3] Univ Munster, Inst Med Phys & Biophys, D-48149 Munster, Germany
关键词
AP-MALDI; liquid matrices; mass spectrometry; multiply charged peptides; ASSISTED-LASER-DESORPTION/IONIZATION; ELECTROSPRAY-IONIZATION; VACUUM MALDI; DESORPTION; TRAP;
D O I
10.1002/anie.201208628
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
All charged up: High and prolonged yields of multiply charged peptide and protein ions can be formed in MALDI mass spectrometry using liquid UV-MALDI matrices and a heated ion-transfer tube. The key features are low laser energies of 1-10 μJ, resulting in fluences of less than 200 to 2000 J m-2 and low sample ablation, high sensitivity, and continuous ion generation over tens of thousands of laser shots. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
引用
收藏
页码:2364 / 2367
页数:4
相关论文
共 24 条
[1]   Liquid ultraviolet matrix-assisted laser desorption/ionization mass spectrometry for automated proteomic analysis [J].
Cramer, R ;
Corless, S .
PROTEOMICS, 2005, 5 (02) :360-370
[2]  
Cramer R, 2000, RAPID COMMUN MASS SP, V14, P53
[3]   The nature of collision-induced dissociation processes of doubly protonated peptides: comparative study for the future use of matrix-assisted laser desorption/ionization on a hybrid quadrupole time-of-flight mass spectrometer in proteomics [J].
Cramer, R ;
Corless, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (22) :2058-2066
[4]   Detection of microorganisms in blood specimens using matrix-assisted laser desorption ionization time-of-flight mass spectrometry: a review [J].
Drancourt, M. .
CLINICAL MICROBIOLOGY AND INFECTION, 2010, 16 (11) :1620-1625
[5]   Hybrid mass spectrometers for tandem mass Spectrometry [J].
Glish, Gary L. ;
Burinsky, David J. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (02) :161-172
[6]   Laserspray Ionization Imaging of Multiply Charged Ions Using a Commercial Vacuum MALDI Ion Source [J].
Inutan, Ellen D. ;
Wager-Miller, James ;
Mackie, Ken ;
Trimpin, Sarah .
ANALYTICAL CHEMISTRY, 2012, 84 (21) :9079-9084
[7]   MATRIX-ASSISTED ULTRAVIOLET-LASER DESORPTION OF NONVOLATILE COMPOUNDS [J].
KARAS, M ;
BACHMANN, D ;
BAHR, U ;
HILLENKAMP, F .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 78 :53-68
[8]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[9]   Generation of highly charged peptide and protein ions by atmospheric pressure matrix-assisted infrared laser desorption/ionization ion trap mass spectrometry [J].
Koenig, Simone ;
Kollas, Oliver ;
Dreisewerd, Klaus .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5484-5488
[10]  
Konermann L, 1998, RAPID COMMUN MASS SP, V12, P435, DOI 10.1002/(SICI)1097-0231(19980430)12:8<435::AID-RCM181>3.0.CO