Determination of fetal heart rate from abdominal signals: evaluation of beat-to-beat accuracy in relation to the direct fetal electrocardiogram

被引:149
作者
Jezewski, Janusz [1 ]
Matonia, Adam [1 ]
Kupka, Tomasz [1 ]
Roj, Dawid [1 ]
Czabanski, Robert [2 ]
机构
[1] Inst Med Technol & Equipment, Dept Biomed Signal Proc, PL-41800 Zabrze, Poland
[2] Silesian Tech Univ, Inst Elect, PL-44100 Gliwice, Poland
来源
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK | 2012年 / 57卷 / 05期
关键词
abdominal signals; fetal electrocardiography; fetal heart rate; fetal monitoring; fetal scalp ECG; QRS DETECTION; TRANSABDOMINAL FETAL; DOPPLER ULTRASOUND; EXTRACTION; ECG; METHODOLOGY;
D O I
10.1515/bmt-2011-0130
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The main aim of our work was to assess the reliability of indirect abdominal electrocardiography as an alternative to the commonly used Doppler ultrasound monitoring technique. As a reference method, we used direct fetal electrocardiography. Direct and abdominal signals were acquired simultaneously, using dedicated instrumentation. The developed method of maternal signal suppression as well as fetal QRS complexes detection was presented. Recordings were collected during established labors, each consisted of four signals from the maternal abdomen and the reference signal acquired directly from the fetal head. After assessing the performance of the QRS detector, the accuracy of fetal heart rate measurement was evaluated. Additionally, to reduce the influence of inaccurately detected R-waves, some validation rules were proposed. The obtained results revealed that the indirect method is able to provide an accuracy sufficient for a reliable assessment of fetal heart rate variability. However, the method is very sensitive to recording conditions, influencing the quality of signals. Our investigations confirmed that abdominal electrocardiography, even in its current stage of development, offers an accuracy equal to or higher than an ultrasound method, at the same time providing some additional features.
引用
收藏
页码:383 / 394
页数:12
相关论文
共 36 条
[1]   Analysis of first-derivative based QRS detection algorithms [J].
Arzeno, Natalia M. ;
Deng, Zhi-De ;
Poon, Chi-Sang .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) :478-484
[2]   ABDOMINAL-LEAD FETAL ELECTROCARDIOGRAPHIC R-WAVE ENHANCEMENT FOR HEART-RATE DETERMINATION [J].
AZEVEDO, S ;
LONGINI, RL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (05) :255-260
[3]   COMPARISON OF SVD METHODS TO EXTRACT THE FETAL ELECTROCARDIOGRAM FROM CUTANEOUS ELECTRODE SIGNALS [J].
CALLAERTS, D ;
DEMOOR, B ;
VANDEWALLE, J ;
SANSEN, W ;
VANTRAPPEN, G ;
JANSSENS, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (03) :217-224
[4]   Clinically accurate fetal ECG parameters acquired from maternal abdominal sensors [J].
Clifford, Gari ;
Sameni, Reza ;
Ward, Jay ;
Robinson, Julian ;
Wolfberg, Adam J. .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2011, 205 (01) :47.e1-47.e5
[5]   Antenatal assessment using the FECG obtained via abdominal electrodes [J].
Crowe, JA ;
Woolfson, MS ;
HayesGill, BR ;
Peasgood, W ;
MohdAli, MA ;
Huang, Y ;
Herbert, J ;
Huang, XB ;
Harrison, A ;
Gibson, NM ;
Symonds, EM ;
Reed, N ;
Mohajer, M .
JOURNAL OF PERINATAL MEDICINE, 1996, 24 (01) :43-53
[6]   THE AUTONOMIC NERVOUS-SYSTEM AND FETAL HEART-RATE-VARIABILITY [J].
DALTON, KJ ;
DAWES, GS ;
PATRICK, JE .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1983, 146 (04) :456-462
[7]   A COMPARISON OF THE NOISE SENSITIVITY OF 9 QRS DETECTION ALGORITHMS [J].
FRIESEN, GM ;
JANNETT, TC ;
JADALLAH, MA ;
YATES, SL ;
QUINT, SR ;
NAGLE, HT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :85-98
[8]   Fetal electrocardiography: feasibility of long-term fetal heart rate recordings [J].
Graatsma, E. M. ;
Jacod, B. C. ;
van Egmond, L. A. J. ;
Mulder, E. J. H. ;
Visser, G. H. A. .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2009, 116 (02) :334-338
[9]  
Guerrero-Martinez J.F., 2006, 2006 COMPUTERS CARDI, P441
[10]   QUANTITATIVE INVESTIGATION OF QRS DETECTION RULES USING THE MIT/BIH ARRHYTHMIA DATABASE [J].
HAMILTON, PS ;
TOMPKINS, WJ .