Highly selective and sensitive voltammetric sensor based on modified multiwall carbon nanotube paste electrode for simultaneous determination of ascorbic acid, acetaminophen and tryptophan

被引:99
作者
Keyvanfard, Mohsen [1 ]
Shakeri, Razieh [2 ]
Karimi-Maleh, Hassan [1 ]
Alizad, Khadijeh [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Majlesi Branch, Esfahan, Iran
[2] Islamic Azad Univ, Dept Chem, Shahreza Branch, Shahreza, Iran
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2013年 / 33卷 / 02期
关键词
Ascorbic acid; Acetaminophen; Tryptophan; 3,4-Dihydroxycinnamic acid; Voltammetry; Multiwall carbon nanotubes; LIQUID-CHROMATOGRAPHIC DETERMINATION; HEAVY-METAL IONS; SPECTROPHOTOMETRIC DETERMINATION; FLOW-INJECTION; URIC-ACID; AMPEROMETRIC DETERMINATION; ENVIRONMENTAL-SAMPLES; DEHYDROASCORBIC ACID; L-CYSTEINE; OXIDATION;
D O I
10.1016/j.msec.2012.11.005
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A carbon-paste electrode modified with multiwall carbon nanotubes (MWCNTs) was used for the sensitive and selective voltammetric determination of ascorbic acid (AA) in the presence of 3,4-dihydroxycinnamic acid (3,4-DHCA) as mediator. The mediated oxidation of AA at the modified electrode was investigated by cyclic voltammeny (CV), chronoamperommetry and electrochemical impedance spectroscopy (EIS). Also, the values of catalytic rate constant (k), and diffusion coefficient (D) for AA were calculated. Using square wave voltammetty (SWV), a highly selective and simultaneous determination of AA, acetaminophen (AC) and tryptophan (Trp) has been explored at the modified electrode. The modified electrode displayed strong function for resolving the overlapping voltammetric responses of AA, AC and Trp into three well-defined voltammetric peaks. In the mixture containing AA, AC and Trp, the three compounds can well separate from each other with potential differences of 200, 330 and 530 mV between AA and AC, AC and Trp and AA and Trp, respectively, which was large enough to determine AA, AC and Trp individually and simultaneously. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:811 / 816
页数:6
相关论文
共 70 条
[21]   Application of derivative-differential UV spectrophotometry and ratio derivative spectrophotometric determination of mephenoxalone and acetaminophen in combined tablet preparation [J].
Erk, N .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (02) :429-437
[22]   Study on electrochemical behavior of tryptophan at a glassy carbon electrode modified with multi-walled carbon nanotubes embedded cerium hexacyanoferrate [J].
Fang, Bin ;
Wei, Yan ;
Li, Maoguo ;
Wang, Guangfeng ;
Zhang, Wei .
TALANTA, 2007, 72 (04) :1302-1306
[23]  
Galus Z., 1976, FUNDUMENTALS ELECTRO
[24]   Determination of ascorbic acid in a mixture of ascorbic acid and uric acid at a chemically modified electrode [J].
Gao, ZQ ;
Siow, KS ;
Ng, A ;
Zhang, YM .
ANALYTICA CHIMICA ACTA, 1997, 343 (1-2) :49-57
[25]   Flow injection spectrophotometric or conductometric determination of ascorbic acid in a vitamin C tablet using permanganate or ammonia [J].
Grudpan, K ;
Kamfoo, K ;
Jakmunee, J .
TALANTA, 1999, 49 (05) :1023-1026
[26]   Spectrophotometric determination of ascorbic acid using copper(II)-neocuproine reagent in beverages and pharmaceuticals [J].
Güçlü, K ;
Sözgen, K ;
Tütem, E ;
Özyürek, M ;
Apak, R .
TALANTA, 2005, 65 (05) :1226-1232
[27]   OXIDATION OF HYDRAZINE ON PLATINUM IN ACID SOLUTION [J].
HARRISON, JA ;
KHAN, ZA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 28 (01) :131-&
[28]  
Keyvanfard M., 2012, J SOLID STATE ELECTR
[29]  
Kochen Walter., 1994, L-Tryptophan: Current Prospects in Medicine and Drug Safety
[30]  
Krzysztof J. R., 2001, ARCH BIOCHEM BIOPHYS, V427, P16