Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance

被引:10
|
作者
Huang, Yen-Cho [1 ]
Yeh, Chien-Yi [2 ]
Yeh, Jih-Hsiang [1 ]
Lo, Ching-Jung [2 ]
Tsai, Ping-Fang [2 ]
Hung, Chih-Hung [2 ]
Tsai, Chieh-Sheng [1 ]
Chen, Chen-Yuan [2 ]
机构
[1] Chang Gung Mem Hosp, Dept Radiat Oncol, Keelung Branch, Keelung 20445, Taiwan
[2] Chang Gung Mem Hosp, Dept Radiat Oncol, Linkou Branch, Tao Yuan, Taoyuan County, Taiwan
关键词
IMAT; EPID; RapidArc; Quality assurance; VMAT; DOSE-RESPONSE CHARACTERISTICS; FIXED FIELD IMRT; MODULATED ARC; CORRECTION ALGORITHM; GLAAS ALGORITHM; DOSIMETRY; RADIOTHERAPY; DELIVERY; RAPIDARC; THERAPY;
D O I
10.1016/j.meddos.2012.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Volumetric-modulated arc therapy (VMAT) is a novel extension of the intensity-modulated radiation therapy (IMRT) technique, which has brought challenges to dose verification. To perform VMAT pretreatment quality assurance, an electronic portal imaging device (EPID) can be applied. This study's aim was to evaluate EPID performance for VMAT dose verification. First, dosimetric characteristics of EPID were investigated. Then 10 selected VMAT dose plans were measured by EPID with the rotational method. The overall variation of EPID dosimetric characteristics was within 1.4% for VMAT. The film system serving as a conventional tool for verification showed good agreement both with EPID measurements ([94.1 +/- 1.5]% with 3 mm/3% criteria) and treatment planning system (TPS) calculations ([97.4 +/- 2.8]% with 3 mm/3% criteria). In addition, EPID measurements for VMAT presented good agreement with TPS calculations ([99.1 +/- 0.6]% with 3 mm/3% criteria). The EPID system performed the robustness of potential error findings in TPS calculations and the delivery system. This study demonstrated that an EPID system can be used as a reliable and efficient quality assurance tool for VMAT dose verification. (c) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [41] Transmission dosimetry with a liquid-filled electronic portal imaging device
    Essers, M
    Boellaard, R
    vanHerk, M
    Lanson, H
    Mijnheer, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (04): : 931 - 941
  • [42] Development and testing of an improved dosimetry system using a backscatter shielded electronic portal imaging device
    King, Brian W.
    Morf, Daniel
    Greer, Peter B.
    MEDICAL PHYSICS, 2012, 39 (05) : 2839 - 2847
  • [43] Quality assurance of gating response times for surface guided motion management treatment delivery using an electronic portal imaging detector
    Barfield, Gary
    Burton, Edward William
    Stoddart, Jonathan
    Metwaly, Mohamed
    Cawley, Martin Gerard
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [44] Image Quality and Information Parameters of Electronic Portal Imaging Devices
    Tzomakas, Marios K.
    Peppa, Vasiliki
    Alexiou, Antigoni
    Karakatsanis, Georgios
    Episkopakis, Anastasios
    Michail, Christos
    Valais, Ioannis
    Fountos, George
    Kalyvas, Nektarios
    Kandarakis, Ioannis S.
    APPLIED SCIENCES-BASEL, 2024, 14 (22):
  • [45] Initial Clinical Experience with Electronic Portal Imaging Device-Based In Vivo Dosimetry for Radiotherapy in Gynecological Cancers
    Yedekci, Yagiz
    Yuce Sari, Sezin
    Gultekin, Melis
    Yildiz, Ferah
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (04): : 446 - 452
  • [46] Retrospective analysis of portal dosimetry pre-treatment quality assurance of intracranial SRS/SRT VMAT treatment plans
    Osei, Ernest
    Graves, Sarah
    Darko, Johnson
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (04) : 540 - 552
  • [47] A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography
    Njeh, Christopher F.
    Caroprese, Blas
    Desai, Pushkar
    RADIATION ONCOLOGY, 2012, 7
  • [48] A test tool for the visual verification of light and radiation fields using film or an electronic portal imaging device
    Dunscombe, P
    Humphreys, S
    Leszczynski, K
    MEDICAL PHYSICS, 1999, 26 (02) : 239 - 243
  • [49] Electronic Portal Imaging Device Dosimetry for IMRT: a Review on Commercially Available Solutions
    Bawazeer, Omemh
    Herath, Sisira
    Sarasanandarajah, Siva
    Deb, Pradip
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 553 - 556
  • [50] Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging
    Zwan, Benjamin J.
    Barnes, Michael P.
    Hindmarsh, Jonathan
    Lim, Seng B.
    Lovelock, Dale M.
    Fuangrod, Todsaporn
    O'Connor, Daryl J.
    Keall, Paul J.
    Greer, Peter B.
    MEDICAL PHYSICS, 2017, 44 (08) : 3909 - 3922