Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance

被引:10
|
作者
Huang, Yen-Cho [1 ]
Yeh, Chien-Yi [2 ]
Yeh, Jih-Hsiang [1 ]
Lo, Ching-Jung [2 ]
Tsai, Ping-Fang [2 ]
Hung, Chih-Hung [2 ]
Tsai, Chieh-Sheng [1 ]
Chen, Chen-Yuan [2 ]
机构
[1] Chang Gung Mem Hosp, Dept Radiat Oncol, Keelung Branch, Keelung 20445, Taiwan
[2] Chang Gung Mem Hosp, Dept Radiat Oncol, Linkou Branch, Tao Yuan, Taoyuan County, Taiwan
关键词
IMAT; EPID; RapidArc; Quality assurance; VMAT; DOSE-RESPONSE CHARACTERISTICS; FIXED FIELD IMRT; MODULATED ARC; CORRECTION ALGORITHM; GLAAS ALGORITHM; DOSIMETRY; RADIOTHERAPY; DELIVERY; RAPIDARC; THERAPY;
D O I
10.1016/j.meddos.2012.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Volumetric-modulated arc therapy (VMAT) is a novel extension of the intensity-modulated radiation therapy (IMRT) technique, which has brought challenges to dose verification. To perform VMAT pretreatment quality assurance, an electronic portal imaging device (EPID) can be applied. This study's aim was to evaluate EPID performance for VMAT dose verification. First, dosimetric characteristics of EPID were investigated. Then 10 selected VMAT dose plans were measured by EPID with the rotational method. The overall variation of EPID dosimetric characteristics was within 1.4% for VMAT. The film system serving as a conventional tool for verification showed good agreement both with EPID measurements ([94.1 +/- 1.5]% with 3 mm/3% criteria) and treatment planning system (TPS) calculations ([97.4 +/- 2.8]% with 3 mm/3% criteria). In addition, EPID measurements for VMAT presented good agreement with TPS calculations ([99.1 +/- 0.6]% with 3 mm/3% criteria). The EPID system performed the robustness of potential error findings in TPS calculations and the delivery system. This study demonstrated that an EPID system can be used as a reliable and efficient quality assurance tool for VMAT dose verification. (c) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [31] Determination of the electronic portal imaging device pixel-sensitivity-map for quality assurance applications. Part 1: Comparison of methods
    Barnes, Michael Paul
    Sun, Baozhou
    Oborn, Brad Michael
    Lamichhane, Bishnu
    Szwec, Stuart
    Schmidt, Matthew
    Cai, Bin
    Menk, Frederick
    Greer, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (06):
  • [32] Quality assurance of MLC leaf position accuracy and relative dose effect at the MLC abutment region using an electronic portal imaging device
    Sumida, Iori
    Yamaguchi, Hajime
    Kizaki, Hisao
    Koizumi, Masahiko
    Ogata, Toshiyuki
    Takahashi, Yutaka
    Yoshioka, Yasuo
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (05) : 798 - 806
  • [33] Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics
    Gopal, Arun
    Samant, Sanjiv S.
    MEDICAL PHYSICS, 2009, 36 (06) : 2006 - 2015
  • [34] Performance of a linear accelerator couch positioning quality control task using an electronic portal imaging device
    Afzalifar, A.
    Mowlavi, A. A.
    Mohammadi, M.
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (02) : 195 - 200
  • [35] Performance of a linear accelerator couch positioning quality control task using an electronic portal imaging device
    A. Afzalifar
    A. A. Mowlavi
    M. Mohammadi
    Radiological Physics and Technology, 2020, 13 : 195 - 200
  • [36] Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance
    Lim, Sangwook
    Ma, Sun Young
    Jeung, Tae Sig
    Yi, Byong Yong
    Lee, Sang Hoon
    Lee, Suk
    Cho, Sam Ju
    Choi, Jinho
    MEDICAL DOSIMETRY, 2012, 37 (03) : 296 - 304
  • [37] Determination of the electronic portal imaging device pixel-sensitivity-map for quality assurance applications. Part 2: Photon beam dependence
    Barnes, Michael Paul
    Sun, Baozhou
    Oborn, Brad Michael
    Lamichhane, Bishnu
    Szwec, Stuart
    Schmidt, Matthew
    Cai, Bin
    Menk, Frederick
    Greer, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (06):
  • [38] Evaluation of prediction and classification performances in different machine learning models for patient-specific quality assurance of head-and-neck VMAT plans
    Kusunoki, Terufumi
    Hatanaka, Shogo
    Hariu, Masatsugu
    Kusano, Yohsuke
    Yoshida, Daisaku
    Katoh, Hiroyuki
    Shimbo, Munefumi
    Takahashi, Takeo
    MEDICAL PHYSICS, 2022, 49 (01) : 727 - 741
  • [39] Verification of compensator thicknesses using a fluoroscopic electronic portal imaging device
    Pasma, KL
    Kroonwijk, M
    van Dieren, EB
    Visser, AG
    Heijmen, BJM
    MEDICAL PHYSICS, 1999, 26 (08) : 1524 - 1529
  • [40] Reliability analysis of an Electronic Portal Imaging Device (EPID) of a linear accelerator
    Gouveia, Clesia
    Sobral, Jose
    2023 IEEE 7TH PORTUGUESE MEETING ON BIOENGINEERING, ENBENG, 2023, : 52 - 55