Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance

被引:10
|
作者
Huang, Yen-Cho [1 ]
Yeh, Chien-Yi [2 ]
Yeh, Jih-Hsiang [1 ]
Lo, Ching-Jung [2 ]
Tsai, Ping-Fang [2 ]
Hung, Chih-Hung [2 ]
Tsai, Chieh-Sheng [1 ]
Chen, Chen-Yuan [2 ]
机构
[1] Chang Gung Mem Hosp, Dept Radiat Oncol, Keelung Branch, Keelung 20445, Taiwan
[2] Chang Gung Mem Hosp, Dept Radiat Oncol, Linkou Branch, Tao Yuan, Taoyuan County, Taiwan
关键词
IMAT; EPID; RapidArc; Quality assurance; VMAT; DOSE-RESPONSE CHARACTERISTICS; FIXED FIELD IMRT; MODULATED ARC; CORRECTION ALGORITHM; GLAAS ALGORITHM; DOSIMETRY; RADIOTHERAPY; DELIVERY; RAPIDARC; THERAPY;
D O I
10.1016/j.meddos.2012.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Volumetric-modulated arc therapy (VMAT) is a novel extension of the intensity-modulated radiation therapy (IMRT) technique, which has brought challenges to dose verification. To perform VMAT pretreatment quality assurance, an electronic portal imaging device (EPID) can be applied. This study's aim was to evaluate EPID performance for VMAT dose verification. First, dosimetric characteristics of EPID were investigated. Then 10 selected VMAT dose plans were measured by EPID with the rotational method. The overall variation of EPID dosimetric characteristics was within 1.4% for VMAT. The film system serving as a conventional tool for verification showed good agreement both with EPID measurements ([94.1 +/- 1.5]% with 3 mm/3% criteria) and treatment planning system (TPS) calculations ([97.4 +/- 2.8]% with 3 mm/3% criteria). In addition, EPID measurements for VMAT presented good agreement with TPS calculations ([99.1 +/- 0.6]% with 3 mm/3% criteria). The EPID system performed the robustness of potential error findings in TPS calculations and the delivery system. This study demonstrated that an EPID system can be used as a reliable and efficient quality assurance tool for VMAT dose verification. (c) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [21] Validation of Three-dimensional Electronic Portal Imaging Device-based PerFRACTION™ Software for Patient-Specific Quality Assurance
    Sait, A. Aziz
    Figueredo, Jason
    Jones, Glenn W.
    Jones, Kai
    McGowan, Thomas
    Kapatoes, Jeff
    Ramaseshan, Ramani
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (01) : 16 - 20
  • [22] Small field measurements using electronic portal imaging device
    Sait, A. Aziz
    Yoganathan, S. A.
    Jones, Glenn W.
    Patel, Tusar
    Rastogi, Nikhil
    Pandey, S. P.
    Mani, Sunil
    Boopathy, Raghavendiran
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (05):
  • [23] The effect of respiratory motion on electronic portal imaging device dosimetry
    Fielding, Andrew L.
    Mendieta, Jessica Benitez
    Maxwell, Sarah
    Jones, Catherine
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (03): : 45 - 55
  • [24] Survey of patient-specific quality assurance practice for IMRT and VMAT
    Chan, Gordon H.
    Chin, Lee C. L.
    Abdellatif, Ady
    Bissonnette, Jean-Pierre
    Buckley, Lesley
    Comsa, Daria
    Granville, Dal
    King, Jenna
    Rapley, Patrick L.
    Vandermeer, Aaron
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 155 - 164
  • [25] Modeling the temporal-spatial nature of the readout of an electronic portal imaging device (EPID)
    Abbasian, Parandoush
    McCowan, Peter M.
    Rickey, Daniel W.
    Van Uytven, Eric
    McCurdy, Boyd M. C.
    MEDICAL PHYSICS, 2020, 47 (10) : 5301 - 5311
  • [26] Electronic Portal Imaging Device in Pre-Treatment Patient-Specific Quality Assurance of volumetric-modulated arc therapy delivery
    Lau, M. L.
    Abdullah, R.
    Jayamani, J.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [27] Incorrect dosimetric leaf separation in IMRT and VMAT treatment planning: Clinical impact and correlation with pretreatment quality assurance
    Sjolin, Maria
    Edmund, Jens Morgenthaler
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (07): : 918 - 925
  • [28] Dosimetric characteristics of a liquid-filled electronic portal imaging device
    Essers, M
    Hoogervorst, BR
    vanHerk, M
    Lanson, H
    Mijnheer, BJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1265 - 1272
  • [29] Clinical Feasibility of Using an Electronic Portal Imaging Device for Position Verification during Conventional Radiotherapy
    Shen, Yuxiaotong
    Zhang, Jie
    Ge, Yun
    Chen, Ying
    Li, Haiwei
    Sun, Wei
    Ji, Mingxi
    Wei, Quanbo
    Cai, Jing
    Li, Bing
    2016 IEEE 10TH INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE AND ENGINEERING (NANOMED), 2016, : 99 - 103
  • [30] Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software
    Held, Mareike
    Cheung, Joey
    Andujar, Angelica Perez
    Husson, Francois
    Morin, Olivier
    CUREUS, 2018, 10 (02):