Colorimetric detection of volatile organic compounds for shelf-life monitoring of milk

被引:53
作者
Ziyaina, Mohamed [1 ,2 ]
Rasco, Barbara [1 ]
Coffey, Todd [3 ]
Unlu, Gulhan [1 ,5 ,6 ]
Sablani, Shyam S. [4 ]
机构
[1] Washington State Univ, Sch Food Sci, Pullman, WA 99164 USA
[2] Univ Zawia, Anim Sci, Zawia 00218, Libya
[3] Washington State Univ, Dept Math & Stat, Pullman, WA 99164 USA
[4] Washington State Univ, Dept Biol Syst Engn, Pullman, WA 99164 USA
[5] Univ Idaho, Sch Food Sci, 875 Perimeter Dr, Moscow, ID 83844 USA
[6] Univ Idaho, Dept Biol Engn, 875 Perimeter Dr, Moscow, ID 83844 USA
基金
美国食品与农业研究所;
关键词
Nanoparticles; Sensor; Schiff reagent; Shelf life; Silicon dioxide; Spoilage bacteria; PASTEURIZED MILK; METABOLITE PRODUCTION; SILVER NANOPARTICLES; REFRIGERATED STORAGE; SPOILAGE; MICROORGANISMS; COMBINATION; BEHAVIOR; QUALITY; SENSORS;
D O I
10.1016/j.foodcont.2019.01.018
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Colorimetric nanosensors for monitoring food quality and shelf life providea an exciting development with obvious economic benefits. In this study, a colorimetric sensor based on silicon dioxide (SiO2 ) nanoparticles and Schiff s reagent to detect volatile organic compounds (VOCs) generated by the growth of spoilage bacteria in pasteurized whole milk stored at 7, 13, 15, and 19 degrees C was developed. Volatile organic compounds formed from microbial growth were detected using solid-phase microextraction (SPME) and gas chromatography. Volatile organic compounds levels were correlated with microbial growth (aerobic plate counts) and color change throughout the shelf-life period. Color changes due to VOCs generated by spoilage bacteria were detected at all storage temperatures except 7 degrees C. Nanosensor response correlated well with microbial growth in milk. Milk spoilage occurred at 32, 60, and 84 h at 19, 15, and 13 degrees C, respectively and could be detected colorimetrically. Color change, recorded as total color difference (Delta E) for the nanosensor, correlated well with aerobic plate counts (5.0-7.0 log(10) CFU/mL) in milk (R-2 = 0.81-0.96). This colorimetric sensor could be incorporated into food packaging to predict remaining shelf-life benefitting consumers as well as manufacturers and retailers and reducing food loss.
引用
收藏
页码:220 / 226
页数:7
相关论文
共 48 条
[1]  
[Anonymous], 2004, Standard Methods for the Examination of Dairy Products
[2]   Raw or heated cow milk consumption: Review of risks and benefits [J].
Claeys, Wendie L. ;
Cardoen, Sabine ;
Daube, Georges ;
De Block, Jan ;
Dewettinck, Koen ;
Dierick, Katelijne ;
De Zutter, Lieven ;
Huyghebaert, Andre ;
Imberechts, Hein ;
Thiange, Pierre ;
Vandenplas, Yvan ;
Herman, Lieve .
FOOD CONTROL, 2013, 31 (01) :251-262
[3]  
CRAVEN HM, 1992, AUST J DAIRY TECHNOL, V47, P46
[4]  
CROMIE SJ, 1991, AUST J DAIRY TECHNOL, V46, P101
[5]   Chemical/biochemical detection of spoilage [J].
Dainty, RH .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1996, 33 (01) :19-33
[6]   Characterization of chocolate milk spoilage patterns [J].
Douglas, SA ;
Gray, MJ ;
Crandall, AD ;
Boor, KJ .
JOURNAL OF FOOD PROTECTION, 2000, 63 (04) :516-521
[7]  
Eskin M, 2012, BIOCH FOODS
[8]   Characterization of pasteurized fluid milk shelf-life attributes [J].
Fromm, HI ;
Boor, KJ .
JOURNAL OF FOOD SCIENCE, 2004, 69 (08) :M207-M214
[9]  
Gemechu T, 2015, ISABB J Food Agric Sci, V5, P7, DOI [10.5897/ISABBJFAS2014.0017, DOI 10.5897/ISABBJFAS2014.0017]
[10]  
Greenwood, 2003, PRACTICAL FOOD MICRO