Variability of physicochemical properties of an epoxy resin sealer taken from different parts of the same tube

被引:32
作者
Baldi, J. V. [1 ]
Bernardes, R. A. [1 ]
Duarte, M. A. H. [1 ]
Ordinola-Zapata, R. [1 ]
Cavenago, B. C. [1 ]
Moraes, J. C. S. [2 ,3 ]
de Moraes, I. G. [1 ]
机构
[1] Univ Sao Paulo, Bauru Dent Sch, Dept Operat Dent Dent Mat & Endodont, Bauru, Brazil
[2] Sao Paulo State Univ, Dept Phys, Sao Paulo, Brazil
[3] Sao Paulo State Univ, Dept Chem, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
AH Plus; degree of conversion; physicochemical properties; radiopacity; root canal sealer; ROOT-CANAL SEALERS; ENDODONTIC SEALERS; AH PLUS; INFRARED SPECTROSCOPY; DIGITAL RADIOGRAPHY; PHYSICAL-PROPERTIES; FILLING MATERIALS; FLOW-RATE; RADIOPACITY; CONVERSION;
D O I
10.1111/j.1365-2591.2012.02049.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Baldi JV, Bernardes RA, Duarte MAH, Ordinola-Zapata R, Cavenago BC, Moraes JCS, de Moraes IG. Variability of physicochemical properties of an epoxy resin sealer taken from different parts of the same tube. International Endodontic Journal,similar to 45, 915920, 2012. Abstract Aim To analyse several physicochemical properties of AH Plus (Dentsply DeTrey, Konstanz, Germany), including setting time, flow, radiopacity and the degree of conversion (DC); and to correlate the results with the source of the material: from the beginning, middle or end of the tubes in which they were supplied. Methodology Three experimental groups were established for each property investigated. Group 1 corresponded to material taken from the beginning of tubes A and B; Group 2 corresponded to material taken from the middle of each tube; and group 3 corresponded to that from the end of each tube. The setting time, flow and radiopacity were studied according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. DC was determined from infrared spectra, which were recorded at 1-h intervals for the first 6 h; then, at 2-h intervals for the next 14 h; then, at 24 and 30 h. Data were analysed statistically by analysis of variance (anova), TukeyKramer, KruskalWallis and Dunn tests, with a significance level of 5%. Results Group 1 had a significantly longer setting time (2303 +/- 1058 min) (P < 0.05). Group 3 had the lowest flowability (30.0 +/- 0.7 mm) and the highest radiopacity (14.85 +/- 1.8 mm Al) (P < 0.05). No differences were found for the DC test (P > 0.05). Conclusion The results suggest that segregation occurs between the organic and inorganic components of AH Plus sealer, thereby changing the setting time, flow and radiopacity.
引用
收藏
页码:915 / 920
页数:6
相关论文
共 30 条
[1]   Filling of artificial lateral canals and microleakage and flow of five endodontic sealers [J].
Almeida, J. F. A. ;
Gomes, B. P. F. A. ;
Ferraz, C. C. R. ;
Souza-Filho, F. J. ;
Zaia, A. A. .
INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (09) :692-699
[2]  
American Dental Association, 2000, SPEC 57 END FILL MAT
[3]   Evaluation of the flow rate of 3 endodontic sealers: Sealer 26, AH Plus, and MTA Obtura [J].
Bernardes, Ricardo Affonso ;
Campelo, Adriana de Amorim ;
Junior, Dario Silva S. ;
Pereira, Luciana O. ;
Duarte, Marco Antonio H. ;
Moraes, Ivaldo G. ;
Bramante, Clovis M. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 109 (01) :E41-E43
[4]   Influence of the powder/liquid ratio on the properties of zinc oxide-eugenol-based root canal sealers [J].
Camps, J ;
Pommel, L ;
Bukiet, F ;
About, I .
DENTAL MATERIALS, 2004, 20 (10) :915-923
[5]   Radiopacity of root filling materials using digital radiography [J].
Carvalho-Junior, J. R. ;
Correr-Sobrinho, L. ;
Correr, A. B. ;
Sinhoreti, M. A. C. ;
Consani, S. ;
Sousa-Neto, M. D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (07) :514-520
[6]  
Dentsply, 2005, AH PLUS ROOT CAN SEA
[7]   FOURIER-TRANSFORM INFRARED-ANALYSIS OF DEGREE OF POLYMERIZATION IN UNFILLED RESINS - METHODS COMPARISON [J].
FERRACANE, JL ;
GREENER, EH .
JOURNAL OF DENTAL RESEARCH, 1984, 63 (08) :1093-1095
[8]   Evaluation of physicochemical properties of four root canal sealers [J].
Flores, D. S. H. ;
Rached-Junior, F. J. A. ;
Versiani, M. A. ;
Guedes, D. F. C. ;
Sousa-Neto, M. D. ;
Pecora, J. D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (02) :126-135
[9]   Laboratory evaluation of the physicochemical properties of a new root canal sealer based on Copaifera multijuga oil-resin [J].
Garrido, A. D. B. ;
Lia, R. C. C. ;
Franca, S. C. ;
da Silva, J. F. ;
Astolfi-Filho, S. ;
Sousa-Neto, M. D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (04) :283-291
[10]   Evaluation of the radiopacity of different root canal sealers [J].
Gorduysus, Melahat ;
Avcu, Nihal .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (03) :E135-E140