Cyclic fatigue of Reciproc and WaveOne reciprocating instruments

被引:163
作者
Plotino, G. [1 ]
Grande, N. M. [1 ]
Testarelli, L. [1 ]
Gambarini, G. [1 ]
机构
[1] Univ Roma La Sapienza, Dept Endodont, I-00197 Rome, Italy
关键词
cyclic fatigue; nickel-titanium; reciprocation; NITI ROTARY INSTRUMENTS; NICKEL-TITANIUM FILES; SHAPING ABILITY; RESISTANCE; FRACTURE; CANALS; K3;
D O I
10.1111/j.1365-2591.2012.02015.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Plotino G, Grande NM, Testarelli L, Gambarini G. Cyclic fatigue of Reciproc and WaveOne reciprocating instruments. International Endodontic Journal, 45, 614618, 2012. Abstract Aim To evaluate the cyclic fatigue resistance of Reciproc (R) and WaveOne (R) instruments in simulated root canals. Methodology Two groups of 15 NiTi endodontic instruments of identical tip size of 0.25 mm were tested, group A; Reciproc (R) R25 and group B: WaveOne (R) primary. Cyclic fatigue testing was performed in a stainless steel artificial canal manufactured by reproducing the instruments size and taper. A simulated root canal with a 60 degrees angle of curvature and 5-mm radius of curvature was constructed for both the instruments tested. The centre of the curvature was 5 mm from the tip of the instrument and the curved segment of the canal was approximately 5 mm in length. The Reciproc (R) instruments were activated using the preset programme specific for the Reciproc (R) instruments, whilst the WaveOne (R) instruments were activated using the preset programme specific for the WaveOne (R) instruments. All instruments were rotated until fracture occurred and the time to fracture (TtF) and the length of the fractured tip were recorded and registered. Means and standard deviations of TtF and fragment length were calculated for each system and data were subjected to Students t-test (P < 0.05). Results A statistically significant difference (P < 0.05) was noted between Reciproc (R) and WaveOne (R) instruments. Reciproc (R) R25 instruments were associated with a significant increase in the mean time to fracture when compared with primary WaveOne (R) instruments (130.8 +/- 18.4 vs. 97.8 +/- 15.9 s). There was no significant difference (P > 0.05) in the mean length of the fractured fragments between the instruments. Conclusions Reciproc (R) instruments were associated with a significantly higher cyclic fatigue resistance than WaveOne (R) instruments.
引用
收藏
页码:614 / 618
页数:5
相关论文
共 50 条
  • [31] Surface nanoscale profile of WaveOne, WaveOne Gold, Reciproc, and Reciproc blue, before and after root canal preparation
    AlRahabi, A. Mothanna K.
    Atta, Raghied M.
    [J]. ODONTOLOGY, 2019, 107 (04) : 500 - 506
  • [32] Fatigue Life of Reciproc and Mtwo Instruments Subjected to Static and Dynamic Tests
    Lopes, Helio P.
    Elias, Carlos N.
    Vieira, Marcia V. B.
    Siqueira, Jose F., Jr.
    Mangelli, Marcelo
    Lopes, Weber S. P.
    Vieira, Victor T. L.
    Alves, Flavio R. F.
    Oliveira, Julio C. M.
    Soares, Thaiane G.
    [J]. JOURNAL OF ENDODONTICS, 2013, 39 (05) : 693 - 696
  • [33] Torsional and bending resistance of WaveOne Gold, Reciproc and Twisted File Adaptive instruments
    Elsaka, S. E.
    Elnaghy, A. M.
    Badr, A. E.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (11) : 1077 - 1083
  • [34] Cyclic Fatigue Resistance of 3 Different Nickel-Titanium Reciprocating Instruments in Artificial Canals
    Higuera, Oscar
    Plotino, Gianluca
    Tocci, Luigi
    Carrillo, Gabriela
    Gambarini, Gianluca
    Jaramillo, David E.
    [J]. JOURNAL OF ENDODONTICS, 2015, 41 (06) : 913 - 915
  • [35] Cyclic Fatigue Resistance of Multiused Reciproc Blue Instruments during Retreatment Procedure
    Serefoglu, Burcu
    Kurt, Seniha Micoogullan
    Kaval, Mehmet Emin
    Guneri, Pelin
    Demirci, Gozde Kandemir
    Caliskan, Mehmet Kemal
    [J]. JOURNAL OF ENDODONTICS, 2020, 46 (02) : 277 - 282
  • [36] Does the type of endodontic access influence in the cyclic fatigue resistance of reciprocating instruments?
    Nogueira Leal Silva, Emmanuel Joao
    Attademo, Rafael Santos
    Dutra da Silva, Marcia Cristina
    Pinto, Karem Paula
    Antunes, Henrique dos Santos
    Leal Vieira, Victor Talarico
    [J]. CLINICAL ORAL INVESTIGATIONS, 2021, 25 (06) : 3691 - 3698
  • [37] Is the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments?
    Kiefner, P.
    Ban, M.
    De-Deus, G.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (05) : 430 - 436
  • [38] Wear and Metallographic Analysis of WaveOne and Reciproc NiTi Instruments Before and After Three Uses in Root Canals
    Pirani, Chiara
    Paolucci, Alessandro
    Ruggeri, Oddone
    Bossu, Maurizio
    Polimeni, Antonella
    Gatto, Maria Rosaria Antonella
    Gandolfi, Maria Giovanna
    Prati, Carlo
    [J]. SCANNING, 2014, 36 (05) : 517 - 525
  • [39] Cyclic fatigue of protaper instruments
    Pereira Lopes, Helio
    Lima Moreira, Edson Jorge
    Nelson Elias, Carlos
    Andriola de Almeida, Renata
    Schultz Neves, Monica
    [J]. JOURNAL OF ENDODONTICS, 2007, 33 (01) : 55 - 57
  • [40] Cyclic fatigue resistance of R-Pilot, WaveOne Gold Glider, and ProGlider glide path instruments
    Cangül Keskin
    Uğur İnan
    Murat Demiral
    Ali Keleş
    [J]. Clinical Oral Investigations, 2018, 22 : 3007 - 3012