3,4-Methylenedioxymethylamphetamine detection using a microcantilever-based biosensor

被引:14
|
作者
Tseng, You-Chen [1 ]
Chang, Jeng-Shian [1 ]
Lin, Shiming [1 ,2 ]
Chao, Sheng D. [1 ]
Liu, Chih-Hao [1 ]
机构
[1] Natl Taiwan Univ, Inst Appl Mech, Taipei 106, Taiwan
[2] Natl Taiwan Univ, Coll Med, Ctr Optoelect Biomed, Taipei 100, Taiwan
关键词
3,4-Methylenedioxymethylamphetamine; Microcantilever-based biosensor; Self-assembled monolayer; Anti-MDMA antibody; SENSITIVITY; MDMA; AMPHETAMINE; BINDING; ECSTASY; STRESS; ASSAYS; MODE; RAT;
D O I
10.1016/j.sna.2012.05.036
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a biomolecular layer with highly specific binding that enables determination of low concentrations of 3,4-methylenedioxymethylamphetamine (MDMA) by the immobilization of antibodies. This study examined the interactions of anti-MDMA antibodies with MDMA using a microcantilever-based biosensor. The detection platform is based on the immobilization of affinity monoclonal antibodies onto a sensing surface using a cysteamine-based self-assembled monolayer. Anti-MDMA antibodies conjugated with various concentrations of MDMA were bound to the sensing surface. The intermolecular interaction was observed by monitoring the simultaneous signals (bending deflection and resonant frequency shift) of microcantilevers in phosphate buffered saline (PBS). We demonstrated that anti-MDMA antibodies can respond specifically to their natural ligand, MDMA. Results revealed that the microcantilever-based biosensor can be used to characterize MDMA response profiles of anti-MDMA and provide rich data for immunoassays. In addition to providing a clearer understanding of the biological mechanisms of protein binding, such a biosensor also holds great potential in numerous other fields, such as drug detection, biomedicine, and environmental protection. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:163 / 167
页数:5
相关论文
共 50 条
  • [1] Microcantilever-based biosensor for detection of various biomolecules
    Yoo, Kyung-Ah
    Na, Kwang-Ho
    Joung, Seung-Ryong
    Nahm, Baek-Hie
    Kang, C.J.
    Kim, Yong-Sang
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2006, 45 (1 B): : 515 - 518
  • [2] ACCIDENTAL INGESTION OF ECSTASY (3,4-METHYLENEDIOXYMETHYLAMPHETAMINE)
    RUSSELL, ARB
    SCHWARTZ, RH
    DAWLING, S
    ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (09) : 1114 - 1115
  • [3] Microcantilever-based biosensor for detection of various biomolecules
    Yoo, KA
    Na, KH
    Joung, SR
    Nahm, BH
    Kang, CJ
    Kim, YS
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (1B): : 515 - 518
  • [4] Hyponatremia associated with 3,4-methylenedioxymethylamphetamine ("ecstasy") abuse
    Budisavljevic, MN
    Stewart, L
    Sahn, SA
    Ploth, DW
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2003, 326 (02): : 89 - 93
  • [5] Isotopic characterisation of 3,4-methylenedioxyamphetamine and 3,4-methylenedioxymethylamphetamine (ecstasy)
    Carter, JF
    Titterton, EL
    Murray, M
    Sleeman, R
    ANALYST, 2002, 127 (06) : 830 - 833
  • [6] Fabrication and characteristics of microcantilever-based biosensor for detection of the protein-ligand binding
    Yoo, Kyung-Ah
    Kim, Jun-Hyuk
    Nahm, B. H.
    Kang, C. J.
    Kim, Yong-Sang
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON NANOSCIENCE AND TECHNOLOGY, 2007, 61 : 1308 - 1311
  • [7] DETECTION OF Lactobacillus plantarum 299V USING MICROCANTILEVER-BASED BIOSENSOR WITH DYNAMIC FORCE MICROSCOPY
    Mendoza-Madrigal, A. G.
    Chanona-Perez, J. J.
    Mendez-Mendez, J. V.
    Paacios-Gonzaez, E.
    Calderon-Dominguez, G.
    Hernandez-Sanchez, H.
    REVISTA MEXICANA DE INGENIERIA QUIMICA, 2013, 12 (03): : 379 - 389
  • [8] The pathology of the ring-substituted amphetamine analogue 3,4-methylenedioxymethylamphetamine (MDMA, 'Ecstasy')
    Rutty, GN
    Milroy, CM
    JOURNAL OF PATHOLOGY, 1997, 181 (03): : 255 - 256
  • [9] Inaccuracy in the detection of molecules using two microcantilever-based methods
    Luo, C
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2005, 72 (04): : 617 - 619
  • [10] Ultrasensitive detection of Vibrio cholerae O1 using microcantilever-based biosensor with dynamic force microscopy
    Sungkanak, Usa
    Sappat, Assawapong
    Wisitsoraat, Anurat
    Promptmas, Chamras
    Tuantranont, Adisorn
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 784 - 789