Use of fluorescence shift and fluorescence anisotropy to evaluate the re-binding of template to (S)-propranolol imprinted polymers

被引:20
作者
Hunt, CE [1 ]
Ansell, RJ [1 ]
机构
[1] Univ Leeds, Sch Chem, Leeds LS2 9JT, W Yorkshire, England
关键词
D O I
10.1039/b518248d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The binding of ( R)- and ( S)- propranolol to an ( S)- propranolol imprinted polymer in organic and aqueous solutions has been studied using fluorescence. The amount of propranolol that binds can be measured by separating non-bound propranolol from the polymer by centrifugation, and measuring the fluorescence intensity. However, this work demonstrates that other measurements can indicate how much propranolol has bound without the need to separate bound and non-bound analyte. In toluene + 0.5% AcOH, and in aqueous buffer ( 25 mM citrate pH 6 + 0.5% Triton X100) the fluorescence anisotropy increases as the fraction of analyte bound to the polymer increases. In aqueous buffer, binding to the polymer is also accompanied by a change in the relative intensities of fluorescence at 322 nm and at 352 nm. These non-separation techniques have been used to show that the imprinted polymer binds more ( S)- propranolol than a non-imprinted polymer, and at least in organic solvent, shows selectivity for ( S)- over ( R)- propranolol.
引用
收藏
页码:678 / 683
页数:6
相关论文
共 37 条
  • [1] Molecularly imprinted polymers and optical sensing applications
    Al-Kindy, S
    Badía, R
    Suárez-Rodríguez, JL
    Díaz-García, ME
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2000, 30 (04) : 291 - 309
  • [2] Molecular imprinting science and technology: a survey of the literature for the years up to and including 2003
    Alexander, C
    Andersson, HS
    Andersson, LI
    Ansell, RJ
    Kirsch, N
    Nicholls, IA
    O'Mahony, J
    Whitcombe, MJ
    [J]. JOURNAL OF MOLECULAR RECOGNITION, 2006, 19 (02) : 106 - 180
  • [3] Application of molecular imprinting to the development of aqueous buffer and organic solvent based radioligand binding assays for (S)-propranolol
    Andersson, LI
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (01) : 111 - 117
  • [4] BIOLOGICAL PROPERTIES OF OPTICAL ISOMERS OF PROPRANOLOL AND THEIR EFFECTS ON CARDIAC ARRHYTHMIAS
    BARRETT, AM
    CULLUM, VA
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 1968, 34 (01) : 43 - +
  • [5] Electrochemical sensing with electrodes modified with molecularly imprinted polymer films
    Blanco-López, MC
    Gutiérrez-Fernández, S
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (08) : 1922 - 1928
  • [6] Chen YC, 2004, MATER RES SOC SYMP P, V787, P35
  • [7] Molecular imprinting in chemical sensing - Detection of aromatic and halogenated hydrocarbons as well as polar solvent vapors
    Dickert, FL
    Forth, P
    Lieberzeit, P
    Tortschanoff, M
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (7-8): : 759 - 762
  • [8] Dickert FL, 1998, ADV MATER, V10, P149, DOI 10.1002/(SICI)1521-4095(199801)10:2<149::AID-ADMA149>3.0.CO
  • [9] 2-2
  • [10] Fluorescence polarization immunoassays for pesticides
    Eremin, SA
    Smith, DS
    [J]. COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2003, 6 (03) : 257 - 266