DEFORMATION OF PROSTATE AND SEMINAL VESICLES RELATIVE TO INTRAPROSTATIC FIDUCIAL MARKERS

被引:81
作者
van der Wielen, Gerard J.
Mutanga, Theodore F.
Incrocci, Luca
Kirkels, Wim J. [2 ]
Osorio, Eliana M. Vasquez
Hoogeman, Mischa S.
Heijmen, Ben J. M.
de Boer, Hans C. J. [1 ]
机构
[1] Erasmus MC Daniel den Hoed Canc Ctr, Div Med Phys, Dept Radiat Oncol, NL-3008 AE Rotterdam, Netherlands
[2] Erasmus MC Daniel den Hoed Canc Ctr, Dept Urol, NL-3008 AE Rotterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 72卷 / 05期
关键词
Prostate cancer; Seminal vesicles; Image-guided radiotherapy; Fiducial markers; Organ deformation;
D O I
10.1016/j.ijrobp.2008.07.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify the residual geometric uncertainties after on-line corrections with intraprostatic fiducial markers, this study analyzed the deformation of the prostate and, in particular, the seminal vesicles relative to such markers. Patients and Methods: A planning computed tomography (CT) scan and three repeat CT scans were obtained for 21 prostate cancer patients who had had three to four cylindrical gold markers placed. The prostate and whole seminal vesicles (clinical target volume [CTV]) were delineated on each scan at a slice thickness of 1.5 mm. Rigid body transformations (translation and rotation) mapping the markers onto the planning scan positions were obtained. The translation only (L-only) or both translation and rotation were applied to the delineated CTVs. Next, the residue CTV surface displacements were determined using nonrigid registration of the delineated contours. For translation and rotation of the CTV, the residues represented deformation; for L-only, the residues stemmed from deformation and rotation. L-only represented the residues for most currently applied on-line protocols. The patient and population statistics of the CTV surface displacements were calculated. The intraobserver delineation variation was similarly quantified using repeat delineations for all patients and corrected for. Results: The largest CTV deformations were observed at the anterior and posterior side of the seminal vesicles (population average standard deviation <= 3 mm). Prostate deformation was small (standard deviation <= 1 mm). The increase in these deviations when neglecting rotation (L-only) was small. Conclusion: Although prostate deformation with respect to implanted fiducial markers was small, the corresponding deformation of the seminal vesicles was considerable. Adding marker-based rotational corrections to on-line translation corrections provided a limited reduction in the estimated planning margins. (c) 2008 Elsevier Inc.
引用
收藏
页码:1604 / 1611
页数:8
相关论文
共 25 条
[1]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[2]   A new point matching algorithm for non-rigid registration [J].
Chui, HL ;
Rangarajan, A .
COMPUTER VISION AND IMAGE UNDERSTANDING, 2003, 89 (2-3) :114-141
[3]   Application of the no action level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markers [J].
De Boer, HCJ ;
Van Os, MJH ;
Jansen, PP ;
Heumen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (04) :969-983
[4]   A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload [J].
De Boer, HCJ ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1350-1365
[5]   Phase III pilot study of dose escalation using conformal radiotherapy in prostate cancer: PSA control and side effects [J].
Dearnaley, DP ;
Hall, E ;
Lawrence, D ;
Huddart, RA ;
Eeles, R ;
Nutting, CM ;
Gadd, J ;
Warrington, A ;
Bidmead, M ;
Horwich, A .
BRITISH JOURNAL OF CANCER, 2005, 92 (03) :488-498
[6]   Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy [J].
Deurloo, KEI ;
Steenbakkers, RJHM ;
Zijp, LJ ;
de Bois, JA ;
Nowak, PJCM ;
Rasch, CRN ;
van Herk, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (01) :228-238
[7]   Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer [J].
Hoogeman, MS ;
van Herk, M ;
de Bois, J ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (02) :177-185
[8]  
International Commission in Radiation Units and Measurements, 1993, 50 ICRU
[9]   Cancer statistics, 2007 [J].
Jemal, Ahmedin ;
Siegel, Rebecca ;
Ward, Elizabeth ;
Murray, Taylor ;
Xu, Jiaquan ;
Thun, Michael J. .
CA-A CANCER JOURNAL FOR CLINICIANS, 2007, 57 (01) :43-66
[10]   Treatment of prostate cancer with radiotherapy: Should the entire seminal vesicles be included in the clinical target volume? [J].
Kestin, LL ;
Goldstein, NS ;
Vicini, FA ;
Yan, D ;
Korman, HJ ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (03) :686-697