Biodegradable Cisplatin-Eluting Tracheal Stent for Malignant Airway Obstruction In Vivo and In Vitro Studies

被引:63
作者
Chao, Yin-Kai [1 ]
Liu, Kuo-Sheng [1 ,3 ]
Wang, Yi-Chuan [4 ]
Huang, Yen-Lin [2 ]
Liu, Shih-Jung [3 ]
机构
[1] Chang Gung Mem Hosp, Coll Med, Dept Thorac & Cardiovasc Surg, Linkou, Taiwan
[2] Chang Gung Mem Hosp, Coll Med, Dept Pathol, Linkou, Taiwan
[3] Chang Gung Univ, Dept Mech Engn, Tao Yuan 333, Taiwan
[4] Chang Gung Univ, Grad Inst Med Mechatron, Tao Yuan 333, Taiwan
关键词
TERM-FOLLOW-UP; INTRATUMORAL CHEMOTHERAPY; LUNG-CANCER; METALLIC STENTS; DISEASE;
D O I
10.1378/chest.12-2282
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Self-expandable metallic stents (SEMSs) are effective in the palliation of malignant airway obstruction. Tumor ingrowth, however, frequently occurs because of a shortage of effective local therapy. Additionally, SEMSs are frequently associated with problems of fracture, migration, and difficult removals. Our goal was to develop a novel bioabsorbable stent with cisplatin elution to circumvent such problems. Methods: Biodegradable stents made of polycaprolactone were fabricated by a laboratory-made, microinjection molding machine. In vitro mechanical strength of the stents was compared with the strength of Ultraflex SEMSs. Polylactide-polyglycolide copolymer and cisplatin were coated onto the surfaces of the stents. Elution method and high-performance liquid chromatography (HPLC) analysis were used to examine the in vitro cisplatin release characteristics. In vivo, the stents were surgically implanted into the cervical trachea of 15 New Zealand white rabbits. Bronchoscopic examination was performed weekly (1 to approximately 5 weeks) before killing. Cisplatin concentrations in trachea, lung, and blood were analyzed by HPLC. Histologic examination was also performed. Results: The biodegradable stent exhibited mechanical strength comparable to the strength of Ultraflex SEMSs and provided a steady release of cisplatin for >4 weeks in vitro. The in vivo study showed sustained cisplatin levels in rabbit trachea for >5 weeks with a minimum drug level in blood. Histologic examination showed an intact ciliated epithelium and marked leukocyte inflitration in the submucosa of the stented area. Conclusions: Our study demonstrated that the biodegradable stents provided physical properties comparable to the properties of SEMSs and a sustained release of cisplatin for >5 weeks, which showed great potential in the treatment of malignant airway obstruction.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 17 条
  • [1] Intratumoral administration of cisplatin through a bronchoscope followed by irradiation for treatment of inoperable non-small cell obstructive lung cancer
    Celikoglu, F
    Celikoglu, SI
    York, AM
    Goldberg, EP
    [J]. LUNG CANCER, 2006, 51 (02) : 225 - 236
  • [2] Bronchoscopic intratumoral chemotherapy of lung cancer
    Celikoglu, Firuz
    Celikoglu, Seyhan I.
    Goldberg, Eugene P.
    [J]. LUNG CANCER, 2008, 61 (01) : 1 - 12
  • [3] Endobronchial intratumoral chemotherapy (EITC) followed by surgery in early non-small cell lung cancer with polypoid growth,causing erroneous impression of advanced disease
    Celikoglu, Seyhan I.
    Celikoglu, Firuz
    Goldberg, Eugene P.
    [J]. LUNG CANCER, 2006, 54 (03) : 339 - 346
  • [4] Factors leading to tracheobronchial self-expandable metallic stent fracture
    Chung, Fu-Tsai
    Lin, Shu-Min
    Chen, Hao-Cheng
    Chou, Chun-Liang
    Yu, Chih-Teng
    Liu, Chien-Ying
    Wang, Chun-Hua
    Lin, Horng-Chyuan
    Huang, Chien-Da
    Kuo, Han-Pin
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (05) : 1328 - 1335
  • [5] Central airway obstruction
    Ernst, A
    Feller-Kopman, D
    Becker, HD
    Mehta, AC
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 169 (12) : 1278 - 1297
  • [6] Drug-eluting stents in vascular intervention
    Fattori, R
    Piva, T
    [J]. LANCET, 2003, 361 (9353) : 247 - 249
  • [7] Development of Nanofiber Coated Indomethacin-Eluting Stent for Tracheal Regeneration
    Heo, Dong Nyoung
    Lee, Jung Bok
    Bae, Min Su
    Hwang, Yu-Shik
    Kwon, Kee Hwan
    Kwon, Il Keun
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2011, 11 (07) : 5711 - 5716
  • [8] Long-term follow-up of ultraflex metallic stents in benign and malignant central airway obstruction
    Husain, Syed A.
    Finch, David
    Ahmed, Manzoor
    Morgan, Anthony
    Hetzel, Martin R.
    [J]. ANNALS OF THORACIC SURGERY, 2007, 83 (04) : 1251 - 1256
  • [9] Palliative Treatment of Inoperable Malignant Tracheobronchial Obstruction: Temporary Stenting Combined With Radiation Therapy and/or Chemotherapy
    Kim, Jin Hyoung
    Shin, Ji Hoon
    Song, Ho-Young
    Ohm, Joon-Young
    Lee, Jae Moung
    Lee, Dae Ho
    Kim, Sang-We
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (01) : W38 - W42
  • [10] Outcomes of tracheobronchial stents in patients with malignant airway disease
    Lemaire, A
    Burfeind, WR
    Toloza, E
    Balderson, S
    Petersen, RP
    Harpole, DH
    D'Amico, TA
    [J]. ANNALS OF THORACIC SURGERY, 2005, 80 (02) : 434 - 438