Monte Carlo-based dosimetry of head-and-neck patients treated with SIB-IMRT

被引:31
作者
Sakthi, N [1 ]
Keall, P [1 ]
Mihaylov, I [1 ]
Wu, QW [1 ]
Wu, Y [1 ]
Williamson, JF [1 ]
Schmidt-Ullrich, R [1 ]
Siebers, JV [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 64卷 / 03期
关键词
Monte Carlo; simultaneous integrated boost; IMRT; head-and-neck cancer; dynamic multileaf collimators; radiotherapy;
D O I
10.1016/j.ijrobp.2005.09.049
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the accuracy of previously reported superposition/convolution (SC) dosimetric results by comparing with Monte Carlo (MC) dose calculations for head-and-neck intensity-modulated radiation therapy (IMRT) patients treated with the simultaneous integrated boost technique. Methods and Materials: Thirty-one plans from 24 patients previously treated on a phase I/II head-and-neck squamous cell carcinoma simultaneous integrated boost IMRT protocol were used. Clinical dose distributions, computed with an SC algorithm, were recomputed using an EGS4-based MC algorithm. Phantom-based dosimetry quantified the fluence prediction accuracy of each algorithm. Dose-volume indices were used to compare patient dose distributions. Results and Discussion: The MC algorithm predicts flat-phantom measurements better than the SC algorithm. Average patient dose indices agreed within 2.5% of the local dose for targets; 5.0% for parotids; and 1.9% for cord and brainstem. However, only 1 of 31 plans agreed within 3% for all indices; 4 of 31 agreed within 5%. In terms of the prescription dose, 4 of 31 plans agreed within 3% for all indices, whereas 28 of 31 agreed within 5%. Conclusions: Average SC-computed doses agreed with MC results in the patient geometry; however deviations >5% were common. The fluence modulation prediction is likely the major source of the dose discrepancy. The observed dose deviations can impact dose escalation protocols, because they would result in shifting patients to higher dose levels. (C) 2006 Elsevier Inc.
引用
收藏
页码:968 / 977
页数:10
相关论文
共 50 条
[31]  
Nelson R, 1985, SLAC265
[32]   Reporting and analyzing dose distributions: A concept of equivalent uniform dose [J].
Niemierko, A .
MEDICAL PHYSICS, 1997, 24 (01) :103-110
[33]   BEAM - A MONTE-CARLO CODE TO SIMULATE RADIOTHERAPY TREATMENT UNITS [J].
ROGERS, DWO ;
FADDEGON, BA ;
DING, GX ;
MA, CM ;
WE, J ;
MACKIE, TR .
MEDICAL PHYSICS, 1995, 22 (05) :503-524
[34]   Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations [J].
Siebers, JV ;
Keall, PJ ;
Nahum, AE ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :983-995
[35]   Comparison of EGS4 and MCNP4b Monte Carlo codes for generation of photon phase space distributions for a Varian 2100C [J].
Siebers, JV ;
Keall, PJ ;
Libby, B ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) :3009-3026
[36]   Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization [J].
Siebers, JV ;
Lauterbach, M ;
Keall, PJ ;
Mohan, R .
MEDICAL PHYSICS, 2002, 29 (06) :952-959
[37]   A method for photon beam Monte Carlo multileaf collimator particle transport [J].
Siebers, JV ;
Keall, PJ ;
Kim, JO ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (17) :3225-3249
[38]  
SIEBERS JV, 2005, IN PRESS INT J RAD O
[39]   Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers [J].
Spezi, E ;
Lewis, DG ;
Smith, CW .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11) :3007-3029
[40]   Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived from basic beam data [J].
Storchi, P ;
Woudstra, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (04) :637-656