Clinical stabilometry standardization Basic definitions - Acquisition interval - Sampling frequency

被引:240
作者
Scoppa, Fabio [1 ]
Capra, Roberto [2 ]
Gallamini, Michele
Shiffer, Riccardo [1 ]
机构
[1] Univ Roma La Sapienza, Fac Med & Dent Surg, Rome, Italy
[2] Univ Genoa, DIST Dept, La Colletta Bioengn Ctr, I-16126 Genoa, Italy
关键词
Clinical Static Stabilometry; Force Platform; Romberg Test; TEST-RETEST RELIABILITY; PRESSURE MEASURES; POSTURAL CONTROL; POSITION; BALANCE; SYSTEM; SWAY;
D O I
10.1016/j.gaitpost.2012.07.009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Several statements on the still debated issue of stabilometry standardization were agreed upon by the ISPGR Standardization Committee. A set of metrological characteristics for stabilometric platforms was defined. Relying both on practice and experimental verification it was agreed that, to obtain appropriate accuracy and sensitivity in the Romberg Test: The acquisition interval should not be less than 25 s. The sampling frequency should be at least 50 Hz. After careful consideration it was decided that the recommendations made in the previous Standardization proposal in 1983 regarding environmental conditions should be maintained. (C) 2012 Elsevier B.V. All rights reserved..
引用
收藏
页码:290 / 292
页数:3
相关论文
共 15 条
[1]   A new look at posturographic analysis in the clinical context: Sway-density versus other parameterization techniques [J].
Baratto, L ;
Morasso, PG ;
Re, C ;
Spada, G .
MOTOR CONTROL, 2002, 6 (03) :246-270
[2]  
Baratto L., 2006, ITAL J REHAB MED MR, V20, P103
[3]   Specifications for building a vertical force platform designed for clinical stabilometry [J].
Bizzo, G. ;
Guillet, N. ;
Patat, A. ;
Gagey, P.M. .
Medical and Biological Engineering and Computing, 1985, 23 (05) :474-476
[4]  
Blaszczyk JW, 2001, ACTA NEUROBIOL EXP, V61, P327
[5]  
Blaszczyk JW, 2001, ACTA NEUROBIOL EXP, V61, P105, DOI 10.55782/ane-2001-1390
[6]   Body sway during quiet standing: Is it the residual chattering of an intermittent stabilization process? [J].
Bottaro, A ;
Casadio, M ;
Morasso, PG ;
Sanguineti, V .
HUMAN MOVEMENT SCIENCE, 2005, 24 (04) :588-615
[7]   Development of a novel method for assessing balance: the quantitative posturography system [J].
Browne, J ;
O'Hare, N .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (04) :525-534
[8]   A quality control procedure for force platforms [J].
Browne, J ;
O'Hare, N .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (04) :515-524
[9]   UPRIGHT, CORRELATED RANDOM-WALKS - A STATISTICAL-BIOMECHANICS APPROACH TO THE HUMAN POSTURAL CONTROL-SYSTEM [J].
COLLINS, JJ ;
DE LUCA, CJ .
CHAOS, 1995, 5 (01) :57-63
[10]  
Gagey PM, 2001, MESURE POSTUROLOGIE