Paired emitter-detector diode detection with dual wavelength monitoring for enhanced sensitivity to transition metals in ion chromatography with post-column reaction

被引:19
作者
Toole, Martina O' [1 ]
Barron, Leon [2 ]
Shepherd, Roderick [3 ]
Paull, Brett [2 ]
Nesterenko, Pavel [2 ]
Diamond, Dermot [1 ]
机构
[1] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Adapt Sensors Grp, Dublin 9, Ireland
[2] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Separat Sci Cluster, Dublin 9, Ireland
[3] Univ Wollongong, Intelligent Polymer Res Inst, Wollongong, NSW 2522, Australia
基金
爱尔兰科学基金会;
关键词
FLOW-INJECTION ANALYSIS; MICROCHIP SEPARATIONS; ABSORBENCY DETECTION; REFRACTIVE-INDEX; OPTICAL SENSORS; ALKALINE-EARTH; COMPENSATION; PHOSPHATE; DEVICES; SAMPLES;
D O I
10.1039/b812612g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combination of post-column derivatisation and visible detection are regularly employed in ion chromatography (IC) to detect poorly absorbing species. Although this mode is often highly sensitive, one disadvantage is the increase in repeating baseline artifacts associated with out-of-sync pumping systems. The work presented here will demonstrate the use of a second generation design paired emitter-detector diode (PEDD-II) detection mode offering enhanced sensitivity to transition metals in IC by markedly reducing this problem and also by improving signal noise. First generation designs demonstrated the use of a single integrated PEDD detector cell as a simple, small (15 x 5 mm), highly sensitive, low cost photometric detector for the detection of metals in IC. The basic principle of this detection mode lies in the employment of two linear light emitting diodes (LEDs), one operating in normal mode as a light source and the other in reverse bias serving as a light detector. The second generation PEDD-II design showed increased sensitivity for Mn(II)- and Co(II)-2(pyridylazo) resorcinol (PAR) complexes as a result of two simultaneously acquiring detection cells - one analytical PEDD cell and one reference PEDD cell. Therefore, the PEDD-II employs two wavelengths whereby one monitors the analyte reaction product and the second monitors a wavelength close to the isosbestic point. The optimum LED wavelength to be used for the analytical cell was investigated to maximise peak response. The fabrication process for both the analytical and reference PEDD cells was validated by determining the reproducibility of detectors within a batch. The reproducibility and sensitivity of the PEDD-II detector was then investigated using signals obtained from both intra- and inter-day chromatograms.
引用
收藏
页码:124 / 130
页数:7
相关论文
共 29 条
[1]   Low pressure ion chromatography with a low cost paired emitter-detector diode based detector for the determination of alkaline earth metals in water samples [J].
Barron, Leon ;
Nesterenko, Pavel N. ;
Diamond, Dermot ;
O'Toole, Martina ;
Lau, King Tong ;
Paull, Brett .
ANALYTICA CHIMICA ACTA, 2006, 577 (01) :32-37
[2]   A REVIEW OF REACTION DETECTION IN HPLC [J].
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1987, 24 :190-200
[3]   PERFORMANCE OF ANNULAR MEMBRANE AND SCREEN-TEE REACTORS FOR POSTCOLUMN-REACTION DETECTION OF METAL-IONS SEPARATED BY LIQUID-CHROMATOGRAPHY [J].
CASSIDY, RM ;
ELCHUK, S ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1987, 59 (01) :85-90
[4]   POSTCOLUMN TECHNIQUES - A CRITICAL PERSPECTIVE FOR ION CHROMATOGRAPHY [J].
DASGUPTA, PK .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (08) :422-448
[5]   LIGHT-EMITTING DIODE BASED FLOW-THROUGH OPTICAL-ABSORPTION DETECTORS [J].
DASGUPTA, PK ;
BELLAMY, HS ;
LIU, HH ;
LOPEZ, JL ;
LOREE, EL ;
MORRIS, K ;
PETERSEN, K ;
MIR, KA .
TALANTA, 1993, 40 (01) :53-74
[6]   Light emitting diode-based detectors absorbance, fluorescence and spectroelectrochemical measurements in a planar flow-through cell [J].
Dasgupta, PK ;
Eom, IY ;
Morris, KJ ;
Li, JZ .
ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) :337-364
[7]   Frequency-selective absorbance detection: Refractive index and turbidity compensation with dual-wavelength measurement [J].
Eom, In-Yong ;
Dasgupta, Purnendu K. .
TALANTA, 2006, 69 (04) :906-913
[8]  
Geschke O., 2004, MICROSYSTEM ENG LAB
[9]   Recent developments in optical detection methods for microchip separations [J].
Gotz, Sebastian ;
Karst, Uwe .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (01) :183-192
[10]  
HADDAD PR, 1990, CHROMATOGRAPHY PRINC