COMPARISON OF TWO BIOELECTRICAL IMPEDANCE ANALYSIS DEVICES WITH DUAL ENERGY X-RAY ABSORPTIOMETRY AND MAGNETIC RESONANCE IMAGING IN THE ESTIMATION OF BODY COMPOSITION

被引:91
作者
Wang, Ji-Guang [1 ]
Zhang, Yi [1 ]
Chen, Han-E [1 ]
Li, Yan [1 ]
Cheng, Xiao-Guang [2 ]
Xu, Li [2 ]
Guo, Zhe [2 ]
Zhao, Xing-Shan [3 ]
Sato, Tetsuya [4 ]
Cao, Qi-Yun [5 ]
Chen, Ke-Min [6 ]
Li, Biao [7 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Ctr Epidemiol Studies & Clin Trials, Shanghai Inst Hypertens,Ruijin Hosp, Shanghai 200030, Peoples R China
[2] Beijing Univ, Jishuitan Hosp, Dept Radiol, Beijing 100871, Peoples R China
[3] Beijing Univ, Jishuitan Hosp, Dept Cardiol, Beijing 100871, Peoples R China
[4] Omron Healthcare, Kyoto, Japan
[5] Omron Healthcare, Shanghai, Peoples R China
[6] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Radiol, Shanghai 200030, Peoples R China
[7] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Nucl Med, Shanghai 200030, Peoples R China
关键词
fat; skeletal muscle; visceral fat; measurement; accuracy; SKELETAL-MUSCLE MASS; VALIDATION; APPLICABILITY; PREVALENCE; PREDICTION; OVERWEIGHT; EQUATION;
D O I
10.1519/JSC.0b013e31824f2040
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Wang, J-G, Zhang, Y, Chen, H-E, Li, Y, Cheng, X-G, Xu, L, Guo, Z, Zhao, X-S, Sato, T, Cao, Q-Y, Chen, K-M, and Li, B. Comparison of two bioelectrical impedance analysis devices with dual energy X-ray absorptiometry and magnetic resonance imaging in the estimation of body composition. J Strength Cond Res 27(1): 236-243, 2013-We compared a 4-limb bioelectrical impedance analysis (BIA) system, HBF 359 (Omron), and a 2-limb foot-to-foot device, BC 532 (Tanita), with the standard dual energy X-ray absorptiometry (DXA) and magnetic resonance imaging (MRI) methods for the measurement of body fat percentage (BF), skeletal muscle mass percentage (SMM, or fat-free mass [FFM] for BC 532), and visceral fat level (VF). Body composition was measured in 200 healthy volunteers (100 men and 100 women, mean age 48 years) by HBF 359 and BC 532 and by DXA and MRI. The agreement was assessed by correlation analysis and paired t-test. The correlation coefficients between BIA and DXA or MRI ranged from 0.71 to 0.89 for BF, SMM, and VF by HBF 359 and from 0.77 to 0.90 for BF, FFM, and VF by BC 532 in all subjects and in men and women separately (p < 0.001 for all). Compared with DXA, HBF 359 significantly (p < 0.001) underestimated BF by -5.8% in men and -9.6% in women. Compared with MRI, the corresponding underestimatons (negative) or overestimations (positive) by HBF 359 in men and women were, respectively, +1.9% (p = 0.02) and +1.7% (p = 0.10) for SMM, and +13.3% (p < 0.001) and -8.5% (p = 0.006), for VF. The corresponding values by BC 532 in men and women were -10.7 and -6.2% for BF, -1.4 and -2.5% for FFM, and +20.4 and -18.0% for VF. The BIA devices are accurate in the estimation of body composition, especially skeletal muscle mass or FFM.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 50 条
  • [1] Accuracy of Bioelectrical Impedance Consumer Devices for Measurement of Body Composition in Comparison to Whole Body Magnetic Resonance Imaging and Dual X-Ray Absorptiometry
    Bosy-Westphal, Anja
    Later, Wiebke
    Hitze, Britta
    Sato, Tetsuya
    Kossel, Elke
    Glueer, Claus-Christian
    Heller, Martin
    Mueller, Manfred James
    OBESITY FACTS, 2008, 1 (06) : 319 - 324
  • [2] Comparing Bioelectrical Impedance Analysis, Air Displacement Plethysmography, and Dual-Energy X-Ray Absorptiometry for Body Composition in Pediatric Obesity
    Thajer, Alexandra
    Vasek, Martin
    Schneider, Sophie
    Kautzky-Willer, Alexandra
    Kainberger, Franz
    Durstberger, Sebastian
    Kranzl, Andreas
    Horsak, Brian
    Greber-Platzer, Susanne
    NUTRIENTS, 2025, 17 (06)
  • [3] Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry
    Rae, L. S.
    Vankan, D. M.
    Rand, J. S.
    Flickinger, E. A.
    Ward, L. C.
    VETERINARY JOURNAL, 2016, 212 : 65 - 70
  • [4] Bioelectrical impedance analysis to estimate body composition, and change in adiposity, in overweight and obese adolescents: comparison with dual-energy x-ray absorptiometry
    Wan, Ching S.
    Ward, Leigh C.
    Halim, Jocelyn
    Gow, Megan L.
    Ho, Mandy
    Briody, Julie N.
    Leung, Kelvin
    Cowell, Chris T.
    Garnett, Sarah P.
    BMC PEDIATRICS, 2014, 14
  • [5] Comparison of Body Composition by Bioelectrical Impedance and Dual-Energy X-Ray Absorptiometry in Overweight/Obese Postmenopausal Women
    Fakhrawi, Dina H.
    Beeson, Lawrence
    Libanati, Cesar
    Feleke, Daniel
    Kim, Hannah
    Quansah, Alfred
    Darnell, Allan
    Lammi-Keefe, Carol J.
    Cordero-MacIntyre, Zaida
    JOURNAL OF CLINICAL DENSITOMETRY, 2009, 12 (02) : 238 - 244
  • [6] A comparison of dual energy X-ray absorptiometry and bioelectrical impedance analysis to measure total and segmental body composition in healthy young adults
    Leahy, Siobhan
    O'Neill, Cian
    Sohun, Rhoda
    Jakeman, Philip
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (02) : 589 - 595
  • [7] A Comparative Study of High-Frequency Bioelectrical Impedance Analysis and Dual-Energy X-ray Absorptiometry for Estimating Body Composition
    Yi, Youngseok
    Baek, Ji Yeon
    Lee, Eunju
    Jung, Hee-Won
    Jang, Il-Young
    LIFE-BASEL, 2022, 12 (07):
  • [8] Comparison of Bioelectrical Impedance Analysis and Dual-Energy X-Ray Absorptiometry for Estimating Bone Mineral Content
    Stone, Tori M.
    Wingo, Jonathan E.
    Nickerson, Brett S.
    Esco, Michael R.
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2018, 28 (05) : 542 - 546
  • [9] Increased adiposity in juvenile idiopathic arthritis - A comparison of the bioelectrical impedance analysis and dual-energy X-ray absorptiometry for the assessment of body composition
    Rasanen, Kati
    Soisalo, Katja
    Markula-Patjas, Kati
    Kantanen, Saija
    Sipila, Kalle
    Lakka, Timo A.
    Valve-Dietz, Anna-Kaisa
    Piippo-Savolainen, Eija
    Arikoski, Pekka
    ACTA PAEDIATRICA, 2024, 113 (09) : 2072 - 2080
  • [10] Comparison of body composition measures assessed by bioelectrical impedance analysis versus dual-energy X-ray absorptiometry in the United Kingdom Biobank
    Feng, Qi
    Besevic, Jelena
    Conroy, Megan
    Omiyale, Wemimo
    Lacey, Ben
    Allen, Naomi
    CLINICAL NUTRITION ESPEN, 2024, 63 : 214 - 225