Uncertainty analysis of cross-calibration for HJ-1 CCD camera

被引:19
|
作者
Wang Zuo [1 ,2 ]
Xiao PengFeng [1 ,2 ]
Gu XingFa [3 ,4 ]
Feng XueZhi [1 ,2 ]
Li XiaoYing [3 ,4 ]
Gao HaiLiang [3 ,4 ]
Li Hui [2 ,5 ]
Lin JinTang [2 ,6 ]
Zhang XueLiang [1 ,2 ]
机构
[1] Nanjing Univ, Jiangsu Prov Key Lab Geog Informat Sci & Technol, Nanjing 210093, Jiangsu, Peoples R China
[2] Nanjing Univ, Dept Geog Informat Sci, Nanjing 210093, Jiangsu, Peoples R China
[3] Chinese Acad Sci, Inst Remote Sensing Applicat, State Key Lab Remote Sensing Sci, Beijing 100101, Peoples R China
[4] Beijing Normal Univ, Beijing 100101, Peoples R China
[5] Xiamen Univ Technol, Dept Spatial Informat Sci & Engn, Xiamen 361024, Peoples R China
[6] Minjiang Univ, Dept Geog Sci, Fuzhou 350108, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
cross-calibration; uncertainty analysis; CCD camera; HJ-1; VICARIOUS CALIBRATION; SENSORS; MODIS;
D O I
10.1007/s11431-012-5109-x
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Radiometric calibration of sensor is the basis of quantitative remote sensing, and uncertainty analysis is critical to ensure the accuracy of cross-calibration. Therefore, firstly, cross-calibration formulas were improved by redefining calibration coefficient and spectral band matching factor. In these formulas, c (ci) was redefined as the calibration coefficient of normalized apparent reflectance, and spectral band matching factor as the ratio of normalized apparent reflectance. Secondly, based on the contrast of ideal and actual conditions in cross-calibration, 8 sources of cross-calibration uncertainty were proposed: calibration uncertainty of standard sensor; pixel matching uncertainty; spectral band matching factor uncertainty caused by site altitude setting error, atmospheric parameters setting error, surface spectrum source, surface bidirectional reflectance characteristic, and error of atmospheric radiative transfer model; and uncertainty caused by other factors which were not considered. Finally, the contribution of each uncertainty was further analyzed and discussed for the HJ-1 CCD camera. The results provide many valuable references for evaluating the feasibility of alternative cross-calibration measurements.
引用
收藏
页码:713 / 723
页数:11
相关论文
共 50 条
  • [31] Cross-Calibration of GF-1 PMS Sensor With Landsat 8 OLI and Terra MODIS
    Gao, Hailiang
    Gu, Xingfa
    Yu, Tao
    Sun, Yuan
    Liu, Qiyue
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2016, 54 (08): : 4847 - 4854
  • [32] Combine MODIS and HJ-1 CCD NDVI with logistic model to generate high spatial and temporal resolution NDVI data
    Jiang Jingyi
    Song Jinling
    Wang Jindi
    Xiao Zhiqiang
    EARTH RESOURCES AND ENVIRONMENTAL REMOTE SENSING/GIS APPLICATIONS III, 2012, 8538
  • [33] The spectral model construction between MODIS SWIR and HJ-1 CCD blue channel and its application in aerosol retrieval
    Sun, Changkui
    Sun, Lin
    Li, Dan
    Zhao, Zheng
    Yu, Kun
    ADVANCES IN ENVIRONMENTAL TECHNOLOGIES, PTS 1-6, 2013, 726-731 : 4631 - 4635
  • [34] Radiometric Cross-Calibration of the ZY1-02D Hyperspectral Imager Using the GF-5 AHSI Imager
    Niu, Chao
    Tan, Kun
    Wang, Xue
    Han, Bo
    Ge, Shule
    Du, Peijun
    Wang, Feng
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [35] Sensitivity Analysis of Spectral Band Adjustment Factors For GF-1/WFV Sensor Cross-Calibration
    Zhou Ke
    Liu Li
    Yu Tao
    Gu Xing-fa
    Zheng Feng-bin
    Zang Wen-qian
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (12) : 3809 - 3813
  • [36] In-orbit cross-calibration of HY-1A satellite sensor COCTS
    PAN Delu
    Chinese Science Bulletin, 2004, (23) : 2521 - 2526
  • [37] In-orbit cross-calibration of HY-1A satellite sensor COCTS
    Pan, DL
    He, XQ
    Zhu, QK
    CHINESE SCIENCE BULLETIN, 2004, 49 (23): : 2521 - 2526
  • [38] Cross-Calibration for Data Fusion of EO-1/Hyperion and Terra/ASTER
    Yokoya, Naoto
    Mayumi, Norimasa
    Iwasaki, Akira
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2013, 6 (02) : 419 - 426
  • [39] Tracking radiometric responsivity of optical sensors without on-board calibration systems-case of the Chinese HJ-1A/1B CCD sensors
    Li, Jian
    Chen, Xiaoling
    Tian, Liqiao
    Feng, Lian
    OPTICS EXPRESS, 2015, 23 (02): : 1829 - 1847
  • [40] High-resolution aerosol remote sensing retrieval over urban areas by synergetic use of HJ-1 CCD and MODIS data
    Li, Yingjie
    Xue, Yong
    He, Xingwei
    Guang, Jie
    ATMOSPHERIC ENVIRONMENT, 2012, 46 : 173 - 180