Uncertainty analysis of cross-calibration for HJ-1 CCD camera

被引:19
|
作者
Wang Zuo [1 ,2 ]
Xiao PengFeng [1 ,2 ]
Gu XingFa [3 ,4 ]
Feng XueZhi [1 ,2 ]
Li XiaoYing [3 ,4 ]
Gao HaiLiang [3 ,4 ]
Li Hui [2 ,5 ]
Lin JinTang [2 ,6 ]
Zhang XueLiang [1 ,2 ]
机构
[1] Nanjing Univ, Jiangsu Prov Key Lab Geog Informat Sci & Technol, Nanjing 210093, Jiangsu, Peoples R China
[2] Nanjing Univ, Dept Geog Informat Sci, Nanjing 210093, Jiangsu, Peoples R China
[3] Chinese Acad Sci, Inst Remote Sensing Applicat, State Key Lab Remote Sensing Sci, Beijing 100101, Peoples R China
[4] Beijing Normal Univ, Beijing 100101, Peoples R China
[5] Xiamen Univ Technol, Dept Spatial Informat Sci & Engn, Xiamen 361024, Peoples R China
[6] Minjiang Univ, Dept Geog Sci, Fuzhou 350108, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
cross-calibration; uncertainty analysis; CCD camera; HJ-1; VICARIOUS CALIBRATION; SENSORS; MODIS;
D O I
10.1007/s11431-012-5109-x
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Radiometric calibration of sensor is the basis of quantitative remote sensing, and uncertainty analysis is critical to ensure the accuracy of cross-calibration. Therefore, firstly, cross-calibration formulas were improved by redefining calibration coefficient and spectral band matching factor. In these formulas, c (ci) was redefined as the calibration coefficient of normalized apparent reflectance, and spectral band matching factor as the ratio of normalized apparent reflectance. Secondly, based on the contrast of ideal and actual conditions in cross-calibration, 8 sources of cross-calibration uncertainty were proposed: calibration uncertainty of standard sensor; pixel matching uncertainty; spectral band matching factor uncertainty caused by site altitude setting error, atmospheric parameters setting error, surface spectrum source, surface bidirectional reflectance characteristic, and error of atmospheric radiative transfer model; and uncertainty caused by other factors which were not considered. Finally, the contribution of each uncertainty was further analyzed and discussed for the HJ-1 CCD camera. The results provide many valuable references for evaluating the feasibility of alternative cross-calibration measurements.
引用
收藏
页码:713 / 723
页数:11
相关论文
共 50 条
  • [21] Dynamic Mapping of Rice Growth Parameters Using HJ-1 CCD Time Series Data
    Wang, Jing
    Huang, Jingfeng
    Gao, Ping
    Wei, Chuanwen
    Mansaray, Lamin R.
    REMOTE SENSING, 2016, 8 (11)
  • [22] Radiometric Cross-Calibration of the Wide Field View Camera Onboard GaoFen-6 in Multispectral Bands
    Yang, Aixia
    Zhong, Bo
    Hu, Longfei
    Wu, Shanlong
    Xu, Zhaopeng
    Wu, Hongbo
    Wu, Junjun
    Gong, Xueshuang
    Wang, Haibo
    Liu, Qinhuo
    REMOTE SENSING, 2020, 12 (06)
  • [23] Tradespace Analysis of Cross-Calibration in Missions Observing Ocean Color
    Tapia-Tamayo, I. Josue
    Grogan, Paul T.
    SYSCON 2022: THE 16TH ANNUAL IEEE INTERNATIONAL SYSTEMS CONFERENCE (SYSCON), 2022,
  • [24] Modeling spatiotemporal distribution of PM10 using HJ-1 CCD data in Luoyang, China
    Ye, Luping
    Fang, Linchuan
    Tan, Wenfeng
    Wu, Changguang
    Wu, Hao
    ATMOSPHERIC POLLUTION RESEARCH, 2017, 8 (03) : 555 - 563
  • [25] Cross-calibration of GRID via correlative spectral analysis of GRBs
    Zirui Yang
    Chenyu Wang
    Hanwen Lin
    Xiaofan Pan
    Qize Liu
    Xutao Zheng
    Huaizhong Gao
    Longhao Li
    Qidong Wang
    Jianping Cheng
    Zhi Zeng
    Ming Zeng
    Hua Feng
    Binbin Zhang
    Zhonghai Wang
    Rong Zhou
    Yuanyuan Liu
    Lin Lin
    Jiayong Zhong
    Jianyong Jiang
    Wentao Han
    Yang Tian
    Benda Xu
    Experimental Astronomy, 2025, 59 (3)
  • [26] Radiometric Cross-Calibration of HJ-2A/CCD3 Using the Random Forest Algorithm and a Spectral Interpolation Convolution Method with Sentinel-2/MSI
    Zhou, Xiang
    Chen, Yidan
    Xie, Yong
    Han, Jie
    Shao, Wen
    REMOTE SENSING, 2024, 16 (22)
  • [27] Cross-Calibration of SMART-1 XSM with GOES and RHESSI
    Mikko Väänänen
    Lauri Alha
    Juhani Huovelin
    Solar Physics, 2009, 260 : 479 - 488
  • [28] Cross-Calibration of SMART-1 XSM with GOES and RHESSI
    Vaananen, Mikko
    Alha, Lauri
    Huovelin, Juhani
    SOLAR PHYSICS, 2009, 260 (02) : 479 - 488
  • [29] Radiometric Cross-Calibration of GF-1 PMS Sensor with a New BRDF Model
    Liu, Qiyue
    Yu, Tao
    Gao, Hailiang
    REMOTE SENSING, 2019, 11 (06)
  • [30] Self-Calibration of Camera and Its Uncertainty Analysis
    Wu, Youfu
    Zhou, Gang
    Wu, Jing
    PROCEEDINGS OF INTERNATIONAL SYMPOSIUM ON IMAGE ANALYSIS & SIGNAL PROCESSING, 2009, 2009, : 58 - 62