摘要
Glucose detection is of great significance in biomedical applications. Principles, methods and recent developments in electrochemical glucose sensors are reviewed here. Special attention is given to the discussion on some problems and bottlenecks in areas of nonenzymatic and enzymatic (glucose oxidase-based) amperometric glucose sensing.
引用
收藏
页码:4473 / 4491
页数:19
相关论文
共 242 条
[1]   A Single ZnO Nanofiber-Based Highly Sensitive Amperometric Glucose Biosensor [J].
Ahmad, Mashkoor ;
Pan, Caofeng ;
Luo, Zhixiang ;
Zhu, Jing .
JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (20) :9308-9313
[2]   DIRECT ELECTROCHEMISTRY OF GLUCOSE OXIDASE AT A GOLD ELECTRODE MODIFIED WITH GRAPHENE NANOSHEETS [J].
Alwarappan, Subbiah ;
Singh, Shree R. ;
Pillai, Shreekumar ;
Kumar, Ashok ;
Mohapatra, Shyam .
ANALYTICAL LETTERS, 2012, 45 (07) :746-753
[3]   Comparative Study of Single-, Few-, and Multi layered Graphene toward Enzyme Conjugation and Electrochemical Response [J].
Alwarappan, Subbiah ;
Boyapalle, Sandhya ;
Kumar, Ashok ;
Li, Chen-Zhong ;
Mohapatra, Shyam .
JOURNAL OF PHYSICAL CHEMISTRY C, 2012, 116 (11) :6556-6559
[4]   Enzyme-Doped Graphene Nanosheets for Enhanced Glucose Biosensing [J].
Alwarappan, Subbiah ;
Liu, Chang ;
Kumar, Ashok ;
Li, Chen-Zhong .
JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (30) :12920-12924
[5]   Enzyme inhibition-based biosensors for food safety and environmental monitoring [J].
Amine, A ;
Mohammadi, H ;
Bourais, I ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1405-1423
[6]   Step-by-step avidin-biotin construction of bienzyme electrodes.: Kinetic analysis of the coupling between the catalytic activities of immobilized monomolecular layers of glucose oxidase and hexokinase [J].
Anicet, N ;
Bourdillon, C ;
Moiroux, J ;
Savéant, JM .
LANGMUIR, 1999, 15 (19) :6527-6533
[7]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[8]   Metal decorated graphene nanosheets as immobilization matrix for amperometric glucose biosensor [J].
Baby, Tessy Theres ;
Aravind, S. S. Jyothirmayee ;
Arockiadoss, T. ;
Rakhi, R. B. ;
Ramaprabhu, S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) :71-77
[9]   SiO2 coated Fe3O4 magnetic nanoparticle dispersed multiwalled carbon nanotubes based amperometric glucose biosensor [J].
Baby, Tessy Theres ;
Ramaprabhu, S. .
TALANTA, 2010, 80 (05) :2016-2022
[10]   Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus [J].
Baca, Justin T. ;
Finegold, David N. ;
Asher, Sanford A. .
OCULAR SURFACE, 2007, 5 (04) :280-293